The sensor is behind the heating unit. If the sheet reaches the sensor a few milliseconds too late, it means that there is a problem in the fusing unit and paper jams are shown. The sensor never breaks down, so look for a fault in the fusing unit. Tomorrow, a video about the interesting problem of the heating unit will appear on my channel.
@@MrRicoh what about the fuser thermosters? because i cleaned everythings inside the fuser three times but still showing the same code. some experts are tilling me about the fuser thermosters. so i need your opinion too. Thanks
The thermostat is only a safety feature, and it certainly works once the copier starts up, so it has nothing to do with your problem. But there are also thermostats in the Fuser Unit - they read the temperature and you can actually clean them, but that won't help in the event of a paper jam. As I wrote earlier: remove the heating rollers, check if the bearings have been installed in the right places and if they are not damaged. Preferably install new shafts and bearings. These are now very cheap components and you will eliminate the likelihood of their damage. Remember that the heat rollers, bearings, thermostats and separators on this machine must always be replaced after 120,000 copies. Good luck.
First, replace the paper pick-up roller in the paper cassette. If this does not help, check the Fuser Unit, maybe your rollers and separators are worn out. ✅ Ultrasonic Cleaner - that's where I got it ⬇⬇⬇ ▶ affiliate.geekbuying.com/deeplink.php?affid=5120&url=www.geekbuying.com/item/Geekbes-6-5L-Mechanical-Ultrasonic-Cleaner-522684.html Discount coupon code: NNNJ0Z7W
Buenas noches serán que puedes ayudar tengo una ricoh aficio mp c2550 y me sale codigo 540 como lo soluciono ya le cable la puerta le cambie el rodillo de unidad y aun me sigue saliendo muchas gracias
You're looking in the wrong place. You have a problem with the Fuser Unit - check which elements are worn and replace them. Probably the thermistors need to be replaced.
su video esta bien ilustrativo, y me sirvio para cambiar el rodillo de calor de mi ricoh 3010, lo que me falla es que no pasa la hoja por la unidad de fundido y la pone como acordeon, me puede ayudar para terminar el proceso o alguien que le haya pasado lo mismo porfa.....
Hola ojalá me pudieras apoyar en la unidad fusora hay 3 rodillos 1.- rodillo de calor 2.- rodillo de presión Pero hay otra rodillo el que instala en el minuto 6:01 del vídeo que cuando arma la unidad es el primero que instala pero en el vídeo no ponen que pieza es no como se llama en mi copiadora ese rodillo esta casi solo el metal y necesito reemplazarlo pero no sé cómo se llama En el manual de servido de mi copiadora lo menciona como rodillo de limpieza pero compré uno y me mandaron el que va en la unidad de revelado y ese no me sirve me podrían apoyar a saber cuál pieza es ese rodillo para conseguirlo porfavor ese.tercer rodillo no sé cómo se llama o como lo pido
R significa que está a la derecha Best regards from Poland and good luck. Części do kopiarek www.copy-expert.pl/ Facebook: facebook.com/Copy-Expert-113431678801597/ Części używane www.copy-expert.com/ #RICOH #COPIER #PRINTER #DRUM #TUTORIAL #PHOTOCOPIER #TRANSFER #COPIERPARTS #COPYEXPERT #JEMIOŁEK
Description: Fuser pressure release sensor error Causes: 1. The fuser pressure release sensor does not turn off after passing 3s from the instruction to reduce the fuser pressure by the fuser release motor, or to relocate the paper jam processing position. 2. The fuser pressure release sensor does not turn on after passing 6s from the instruction to increase the fuser pressure by the fuser release motor. 3. The lock-up signal of the fuser release motor is low for 200ms. (However, when shifting to the paper jam processing mode, the fuser release motor is stopped but the service call error does not appear if it is in between the stop position and the position in front of the stop position by 500ms.) Remedy: 1 Reinstalling the fuser unit The drawer connector of the fuser unit is not properly inserted. Check if the pins of the drawer connector of the fuser unit do not bend. If it bend, replace the fuser unit. When the pins are proper, reinstall the fuser unit so that the drawer connector firmly connects. Fuser Unit Replacement 2 Checking the wire The wire is not properly connected or is faulty. Execute U030 [Fuser Release] to check the fuser release motor operation. If it does not operate properly, reinsert the following wire connectors. Then, replace the wires if there is no continuity.• Fuser release motor (in the fuser unit) - Feed drive PWB• Feed drive PWB - Engine PWB• Drawer connector of the fuser unit - Feed image PWB• Feed image PWB - Engine PWB Electrical Diagram of PWBs 3 Replacing the fuser unit The fuser unit is faulty at the fuser pressure release mechanism or the fuser pressure release sensor . Replace the fuser unit. Fuser Unit Replacement 4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Upgrade 5 Replacing the feed drive PWB The feed drive PWB is faulty. Replace the feed drive PWB. 6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Engine PWB Replacement 7 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB. 8 Replacing the fuser release motor The fuser release motor is faulty. Replace the fuser release motor. Fuser Drive Unit Replacement 9 Replacing the gear in the fuser pressure releasing system at the main unit The gear of the fuser pressure releasing mechanism at the main unit is faulty. Replace the gears in the fuser pressure releasing mechanism at the main unit.
It's a beautiful 💗 video
Thank You
This is the unit i am asking about.
is it's sensors causing the paper jams just before this unit and not entering into it?
The sensor is behind the heating unit. If the sheet reaches the sensor a few milliseconds too late, it means that there is a problem in the fusing unit and paper jams are shown. The sensor never breaks down, so look for a fault in the fusing unit. Tomorrow, a video about the interesting problem of the heating unit will appear on my channel.
@@MrRicoh
what about the fuser thermosters?
because i cleaned everythings inside the fuser three times but still showing the same code.
some experts are tilling me about the fuser thermosters. so i need your opinion too.
Thanks
The thermostat is only a safety feature, and it certainly works once the copier starts up, so it has nothing to do with your problem. But there are also thermostats in the Fuser Unit - they read the temperature and you can actually clean them, but that won't help in the event of a paper jam. As I wrote earlier: remove the heating rollers, check if the bearings have been installed in the right places and if they are not damaged. Preferably install new shafts and bearings. These are now very cheap components and you will eliminate the likelihood of their damage. Remember that the heat rollers, bearings, thermostats and separators on this machine must always be replaced after 120,000 copies. Good luck.
If paper jam problem in machine so change this plz answer me
First, replace the paper pick-up roller in the paper cassette. If this does not help, check the Fuser Unit, maybe your rollers and separators are worn out. ✅ Ultrasonic Cleaner - that's where I got it ⬇⬇⬇
▶ affiliate.geekbuying.com/deeplink.php?affid=5120&url=www.geekbuying.com/item/Geekbes-6-5L-Mechanical-Ultrasonic-Cleaner-522684.html
Discount coupon code: NNNJ0Z7W
Buenas noches serán que puedes ayudar tengo una ricoh aficio mp c2550 y me sale codigo 540 como lo soluciono ya le cable la puerta le cambie el rodillo de unidad y aun me sigue saliendo muchas gracias
You're looking in the wrong place. You have a problem with the Fuser Unit - check which elements are worn and replace them. Probably the thermistors need to be replaced.
su video esta bien ilustrativo, y me sirvio para cambiar el rodillo de calor de mi ricoh 3010, lo que me falla es que no pasa la hoja por la unidad de fundido y la pone como acordeon, me puede ayudar para terminar el proceso o alguien que le haya pasado lo mismo porfa.....
UPPER PICKER FINERS x 5 + SPRINGS are responsible for this fault replace it
Hola ojalá me pudieras apoyar en la unidad fusora hay 3 rodillos
1.- rodillo de calor
2.- rodillo de presión
Pero hay otra rodillo el que instala en el minuto 6:01 del vídeo que cuando arma la unidad es el primero que instala pero en el vídeo no ponen que pieza es no como se llama en mi copiadora ese rodillo esta casi solo el metal y necesito reemplazarlo pero no sé cómo se llama
En el manual de servido de mi copiadora lo menciona como rodillo de limpieza pero compré uno y me mandaron el que va en la unidad de revelado y ese no me sirve me podrían apoyar a saber cuál pieza es ese rodillo para conseguirlo porfavor ese.tercer rodillo no sé cómo se llama o como lo pido
Cleaning Roller AE042029
y el desarme de este unidad de fusor...se puede limpiar con algo??
No lo limpies, reemplaza los elementos por otros nuevos.
Hola se me soltó el resorte que está debajo de una chapita con un tornillo...y no se como va ..me podrías mostrar saludos
Send me an email with a photo of the problem, we'll solve it. Mail copy-expert@wp.pl
Como se pone la pieza que esta marcada con R
R significa que está a la derecha Best regards from Poland and good luck.
Części do kopiarek www.copy-expert.pl/
Facebook: facebook.com/Copy-Expert-113431678801597/
Części używane www.copy-expert.com/
#RICOH #COPIER #PRINTER #DRUM #TUTORIAL #PHOTOCOPIER #TRANSFER #COPIERPARTS #COPYEXPERT #JEMIOŁEK
muito bom
I'm glad I could help
Please Help me keyocera 5501i error C6610 after one week
send men vedios
Description: Fuser pressure release sensor error
Causes:
1. The fuser pressure release sensor does not turn off after passing 3s from the instruction to reduce the fuser pressure by the fuser release motor, or to relocate the paper jam processing position.
2. The fuser pressure release sensor does not turn on after passing 6s from the instruction to increase the fuser pressure by the fuser release motor.
3. The lock-up signal of the fuser release motor is low for 200ms. (However, when shifting to the paper jam processing mode, the fuser release motor is stopped but the service call error does not appear if it is in between the stop position and the position in front of the stop position by 500ms.)
Remedy:
1 Reinstalling the fuser unit The drawer connector of the fuser unit is not properly inserted. Check if the pins of the drawer connector of the fuser unit do not bend. If it bend, replace the fuser unit. When the pins are proper, reinstall the fuser unit so that the drawer connector firmly connects. Fuser Unit Replacement
2 Checking the wire The wire is not properly connected or is faulty. Execute U030 [Fuser Release] to check the fuser release motor operation. If it does not operate properly, reinsert the following wire connectors. Then, replace the wires if there is no continuity.• Fuser release motor (in the fuser unit) - Feed drive PWB• Feed drive PWB - Engine PWB• Drawer connector of the fuser unit - Feed image PWB• Feed image PWB - Engine PWB Electrical Diagram of PWBs
3 Replacing the fuser unit The fuser unit is faulty at the fuser pressure release mechanism or the fuser pressure release sensor . Replace the fuser unit. Fuser Unit Replacement
4 Firmware upgrade The firmware is not the latest version. Upgrade the engine firmware to the latest version Firmware Upgrade
5 Replacing the feed drive PWB The feed drive PWB is faulty. Replace the feed drive PWB.
6 Replacing the engine PWB The engine PWB is faulty. Replace the engine PWB. Engine PWB Replacement
7 Replacing the feed image PWB The feed image PWB is faulty. Replace the feed image PWB.
8 Replacing the fuser release motor The fuser release motor is faulty. Replace the fuser release motor. Fuser Drive Unit Replacement
9 Replacing the gear in the fuser pressure releasing system at the main unit The gear of the fuser pressure releasing mechanism at the main unit is faulty. Replace the gears in the fuser pressure releasing mechanism at the main unit.