Connecting A-link - Software

Поділитися
Вставка
  • Опубліковано 1 січ 2025

КОМЕНТАРІ • 34

  • @neilaldridge9261
    @neilaldridge9261 5 років тому +2

    Another great video in the series!
    Software downloaded.
    Now looking forward to the system programming guide you alluded to in this video.

  • @chefiemx5220
    @chefiemx5220 3 місяці тому

    Hi Guys Great video Thank you , Will the 2 ch Bosch RX remote panel EDM345F2 work with the 2000 series panel

  • @MrBoomtheroom
    @MrBoomtheroom 11 місяців тому

    did you end up doing the next video?

  • @ColinFNZ
    @ColinFNZ 4 роки тому +1

    Hi, Thanks for the video (and the alarm :-)). There is one important step which I think is missing and had me scratching my head until I read the manual more fully.
    Before you connect, if you have not already configured your B4xx-M module, (B426 in my case) you first need to program position 81 with a 1 otherwise you can't connect (for a Solution 3000 in my case).
    Might be good to include that in there somewhere?

    • @CheapAlarmParts
      @CheapAlarmParts  4 роки тому

      Great tip! Yes, this video presumes that you already have a communications method set up (be that IP, Cloud or GSM).

  • @marilynmason6437
    @marilynmason6437 4 роки тому

    Hi - Just had success in connecting A-Link to my system - I did have to turn off my VPN to allow A-Link to fing the B426M but once found the system works fine. I have changed the web port to 8020 to allow it to be found on DynDns but I have not tried it out yet I also need to Reserve the Local IP address for the same reason.
    Will need to do further programming for remote access and control but so far the System 3000 has been working ok for the last year. Yy!

  • @lukethis2924
    @lukethis2924 11 місяців тому

    How would I do this with the Control Panel via Phone number or Control Panel IP address?

  • @toninelson2768
    @toninelson2768 4 роки тому +1

    What happens if anew battery will not charge is transformer faulty

    • @CheapAlarmParts
      @CheapAlarmParts  4 роки тому

      Toni Nelson it’s always a good idea to check your transformer with a volt meter. You should be getting around 18Vac at the terminals on the board. If you are getting this and the battery is still not charging you might have an issue with the charging circuit on the main board or a dead or damaged battery.

  • @JasonBolger
    @JasonBolger 2 роки тому

    Great video. My only suggestion would be to add chapter markers for easy fast forwarding :)

  • @lukethis2924
    @lukethis2924 11 місяців тому

    Having trouble downloading this software. Has it moved to somewhere else?

  • @mkp1359
    @mkp1359 5 років тому +1

    THANKS
    PLEASE MAKE ONE VIDEO ON HOW TO CONNECT MOBILE PHONE ON ALARM PANEL 2000

  • @topshelftequilaaustralia1709

    Please help I keep getting this error Fail to connect to panel. SLL connection failed. I have tried everything.

  • @harryg2362
    @harryg2362 2 роки тому

    I successfully connect to the panel. I change the zone names and also the Entry times. I save the settings then get "Failed to transmit the data" when I select "Download to control panel". Any ideas?

  • @itsmee9779
    @itsmee9779 3 роки тому +1

    Why do l get error when connecting.

    • @CheapAlarmParts
      @CheapAlarmParts  3 роки тому +1

      Please, make sure the installer code in the data base is the same in the panel, Make sure the Panel Serie in the top is the same to your Solution and Also, make sure your panel type is the correct.

    • @rana9339
      @rana9339 3 роки тому

      @@CheapAlarmParts Thank you for the video. I've fallowed the video and read all the comments. Cant connect yet.. Anything else I should check. Thanks

  • @royaliptv
    @royaliptv 3 роки тому +1

    Thanks mate

  • @lukethis2924
    @lukethis2924 10 місяців тому

    Hey Paul, I'm doing everything you're saying but I'm still getting a "Communication failure. Check Control Panel Type, Customer number or other related parameters on link" I even tried the cloud option and it will not connect either because I also set it up with cloud and I put the Cloud ID in and it's still not working.

  • @roderickmontales9125
    @roderickmontales9125 7 місяців тому

    I did not get how he connected.

  • @MrBoomtheroom
    @MrBoomtheroom 11 місяців тому

    software link not available anymore?

    • @CheapAlarmParts
      @CheapAlarmParts  11 місяців тому

      You can find the lastest firmware and software on our website www.cheapalarmparts.com.au under "Solution 3000 software".

    • @MrBoomtheroom
      @MrBoomtheroom 11 місяців тому

      what software do you recommend to rename the zones on the 3000?@@CheapAlarmParts

  • @BeingHuman1903
    @BeingHuman1903 4 роки тому

    I have just a code to arm/disarm the system with network access to IP module using default password. I have already tried default codes like 1234 and 2580 etc. Can I reconfigure it over network to set my own codes ?

    • @CheapAlarmParts
      @CheapAlarmParts  4 роки тому +1

      You can only change codes in the system if you have a Master Code or Installer Code. The Alink software won't connect if the Installer Code in Alink doesn't match what's in panel you are trying to connect to. If you don't have any codes, the only options is to default the panel and start again.

    • @BeingHuman1903
      @BeingHuman1903 4 роки тому

      @@CheapAlarmParts thanks for your comments ! If I default the panel I am assuming it won't reset the B426 module also and I would still be able to connect through same network IP?

    • @BeingHuman1903
      @BeingHuman1903 4 роки тому

      While i was checking this option with you the cunning installer I had disabled B426 module remotely since he has master code & the cloud ID both and I cant change the master code without knowing it. No wonder he is referring to your videos to learn about Bosch security system because he himself was a junk !!! :)

    • @CheapAlarmParts
      @CheapAlarmParts  4 роки тому

      So are you sorted now?

    • @BeingHuman1903
      @BeingHuman1903 4 роки тому

      Cheap Alarm Parts I am good for now but still have same query. If I default my Bosch 2000 panel then will it be accessible using B426 module on network for programming? Thanks

  • @dominicraso652
    @dominicraso652 4 роки тому

    good but slow down !