@@PEARLENGINEERING1 I will connect 2 micro switches on 1 button NO and then I put 2 stop buttons NC for Stop I need to stop by hand and microswitch on the machine. The machine has 2 vfd and 2 motors of different sizes and speeds need to start both and stop by the stop button and stop by the microswitch.
@@PEARLENGINEERING1 Which parameter is that for this m series and does any wire configuration needs to be changed in the lower ports i mean short-circuiting ground and run forward or something like that? Please reply 🙏
Same jaise ek push button start ka run karne ke lie lia hai na..waise hi ek aur start push button pahle start ke input se le lo aur is start se out hoke wire ko drive ke m1 terminal pe dal do
Motor ko run command timer ke nc se de do..or on delay function use karo,aur timer ko hold karne ke lie ek relay use karo..relay ko on off Push button se karo..
@PEARL ENGINEERING Relay ko ON/OFF push button ( green - NO via red - NC push button ) se karaya , Relay ke NO se TIMER ko ON karaya TIMER ke NC se " drive " ko ON karaya By shorting digital input of drive & 0volt / 24 volt , ye shorting hi TIMER ke NC se hoogi , there is 1 doubt mere pass ON delay TIMER he , Drive to already ON hi rhegi Jaise hi relay ko ON Kiya TIMER ko supply mil jaegi TIMER ON ho jaega, but TIMER ki relay contact abhi ON nhi honge( kyunki ON delay TIMER he ) and Drive ON ho jaegi ,bulki wo to ON hi he pehle se aur Jbb set time complete hoo jaega TIMER ki relay ON ho jaegi TIMER ki relay ka NC abb NO ho jaega Motor stop hoo jaegi But Next time drive ko ON krne ke liye hme actually me TIMER ko OFF krna pdega Yehi problem he Kyunki jaise hi TIMER ko off krenge Waise hi fir se drive ON hoo jaegi Yahi confusion he
Tumhara matlab compressor ke pressure switch se vfd on off karna hai..uske lie pressure switch ek relay on kara do..aur relay se vfd ko run command de do
Sir aapka bahut aacha samjh araha hai thank you sir ..
Bahut achha..samjhate h sir..
Great work ......Best wishes from Pakistan ❤🇵🇰♥
This is good and it works can I connect 2vfd with 2motor to work on the same button ??????
Will you ansver im waiting
Yes..use 2 no
@@PEARLENGINEERING1 I will connect 2 micro switches on 1 button NO and then I put 2 stop buttons NC for Stop I need to stop by hand and microswitch on the machine.
The machine has 2 vfd and 2 motors of different sizes and speeds need to start both and stop by the stop button and stop by the microswitch.
Good information sir
You can loop ground wire from star pb to sto pb and then connect two separate wires from output of buttons to D terminals
Hi good evening
Can do video andeli VFD with control with plc
Here m2 terminal jog mode can I use.
Yes
If m2 terminal use in jog mode.which terminal use in pushbutton holding
Then use m3
Thank you sir.
Can we run this vfd with 2 input phases .
Yes
Nice good jobe bhai ji
Isike adhar pe hamne aj deta m me 5.5kw ka instalation kiya success huwa hai bhai
If m2 use in jog mode.which terminal use in push button holding.
on push butten dabane pr zero se start hona chahiye , uski setting bataye , please
I want it to automatic start when powered on
Use parameter auto start at power resume
@@PEARLENGINEERING1 Which parameter is that for this m series and does any wire configuration needs to be changed in the lower ports i mean short-circuiting ground and run forward or something like that? Please reply 🙏
Great 👍
Nice information
Potentiometer ka wiring chahiye
What use of RA RB RC terminals in delta vfd
These are relay terminal..rc common ra- no rb- nc
Which occasion use this relay
For alarm indication lamp, for start stop any thing with this vfd,sequence run,and many more uses
Delta m drive ko relay laga kar kaise on kare or uske parameters kya dalte hai please bataye
Video banaya hai..search karo channel me
Dear sir.please jog mode explain
Jog means very slow speed run...wo v jab tak hum jog bada ke rakhenge
VFD ka Full tarminal details ka video banaiye sir
Bhai aisa bahut sara video banaya hai..aap mere channel ke videos me jake dekho
What's the use of mode button.
To see parameter settings, output Frequency ,output current
3 wire mod me stater salzer switch se reverse forward kaise karenge parameter & wiring diagram bataiye se plz reply....
Same jaise ek push button start ka run karne ke lie lia hai na..waise hi ek aur start push button pahle start ke input se le lo aur is start se out hoke wire ko drive ke m1 terminal pe dal do
Good
Dc drive paramitar sating please
sir mujhe aap se training Leni hai
Hello
Delta VFD ke sath off / on delay timer kaise use kre
Please share information.
Thanku.
Complete details batao
@@PEARLENGINEERING1
Meri motor jo VFD se chalegi
Motor on krne ke
10 minutes baad apne aap off hoo jae.
@@PEARLENGINEERING1 mujhe sirf motor ko 10 minutes baad off krna he
Aur motor VFD se chal rhi he
Motor ko run command timer ke nc se de do..or on delay function use karo,aur timer ko hold karne ke lie ek relay use karo..relay ko on off Push button se karo..
@PEARL ENGINEERING
Relay ko ON/OFF push button ( green - NO via red - NC push button ) se karaya ,
Relay ke NO se TIMER ko ON karaya
TIMER ke NC se " drive " ko ON karaya
By shorting digital input of drive & 0volt / 24 volt , ye shorting hi TIMER ke NC se hoogi ,
there is 1 doubt mere pass ON delay TIMER he ,
Drive to already ON hi rhegi
Jaise hi relay ko ON Kiya
TIMER ko supply mil jaegi
TIMER ON ho jaega, but TIMER ki relay contact abhi ON nhi honge( kyunki ON delay TIMER he )
and
Drive ON ho jaegi ,bulki wo to ON hi he pehle se
aur
Jbb set time complete hoo jaega
TIMER ki relay ON ho jaegi
TIMER ki relay ka NC abb NO ho jaega
Motor stop hoo jaegi
But
Next time drive ko ON krne ke liye
hme actually me TIMER ko OFF krna pdega
Yehi problem he
Kyunki jaise hi TIMER ko off krenge
Waise hi fir se drive ON hoo jaegi
Yahi confusion he
Can you make a video on how to connect automatic compressor switch with VFD?
Tumhara matlab compressor ke pressure switch se vfd on off karna hai..uske lie pressure switch ek relay on kara do..aur relay se vfd ko run command de do
Electric engineer ki salary kitni Hoti hai fresar or after expiriance ke bad
Ak video apload kar Dena sir please
App Electric cycle banao
Ha bhai banaunga 😊
Mtld
Source is frequency
aap se sir eng. ban haya
Mujhe delta VFD nahi samjh araha tha
Sir g+3 lift ka panel bnao
ua-cam.com/video/_j53C7uMPHM/v-deo.html
Speak English in your next video, because everybody is views can understand
ban gaya
Tumi horidas pal
Nai samjha bhai..iska kya matlab hua..
ple sir
sir ji aapka no chiye
7600382705