Thank you so much it was very helpful during the Lockdown. A month ago my Kent RO became non functional and due to Lockdown engineers were unable to come over and fix. Came across your video I followed it throughout and my water purifier is working perfectly. Thank you and God Bless you 👍🏻👍🏻👍🏻🙏🏻🙏🏻🙏🏻
Mere red light jalti hai after 3 minutes. Then works well . Before one month their mechanic replaced 3 filters and one outsise sediment filter. Moistures are accumulating inside the box of filter.Why it is taking 3 minutes before startnig? Pl reply.
@@SoneriVishwa ok sir thanks Meine bahar pre filter bhi lagaya hua hai Aap bolte hai na ki TDS adjuster k karan tap wala pani bhi aa jata hai, to kya UV k baad jo peene wala paani aata hai, usse pehle UF lagane ki jarurat hai?
can u tell me iska after buy cost kitna hai filter kits ka? kitne pani filter karne ki bad kis kis filter ko change karna hota hai? and uska price kitna hai?
Pump ka output carbon aur RO dono ko diya jata hain. Same pressure ke saath. Agar aap gaur karenge to carbon inlet par ek T-joint hain. So dono ko sath me hi paani milega
Sir agar mai sediment uske bad carbon uske bad sv uske bad pump uske bad ek T lagakar TDS controller me aur ek membrane ke inlet me agar is tarah ka connection kre to membrane ka life kam ho jati hai kya aisa v kooch hota hai kya plz clearify kro ap sir @@SoneriVishwa
Surely effect hoga. Filter ki life 2 chije decide karti hai . 1. Water quality 2. Water flow Agar paani kharab hain aur acchese flow nahi ho raha hai. To filters kharab ho jate hai. Connections m koi bhi badlaw n kare. Isse pani ki quality me issues aa sakte hain.
Sir thanks. SV jise 24 volt DC diya red & white wire se but agr SV m yellow and blue wire h to kese + P -- N judge kre please sir abhi btaanaa mene connection krna h DC ka
Membrane replacement ke liye ek alarm laga hua hota hai. Wo alarm chalu hone ke baad filter band rehta hain jab tak aap servicing nahi karwate. 2. Totally 6000 tak kharch aa sakta hain.
Membrane ki life Apke ground water ke TDS(Total Dissolve solids in water) pe depend Karti hai agar TDS level jyada h to membrane jaldi choke(block) ho jati hai 🙏
90% membrane choke (block) Hoti h pre-filter ki wajah se Jo Apke R O k pehle LAGI Hoti h, pre-filter jam hone. Ki wajah se dust particles membrane tak pahuch jate h jiski wajah se membrane block ho jati h 🙏
Sir can we connect the uf membrane output water with ro membrane output to uv lamp without the control valve back side the uf membrane Please reply sir
TDS Controller is not an ideal way to add essential minerals in the purified water.100% of the input water does not pass through the RO membrane. Mixing RO purified water with non-RO purified water may result in the presence of several harmful heavy metals like lead and arsenic in the purified water, as these impurities can only be removed by an RO membrane.
if we get our water checked and are sure that water is not having harmful heavy metals like lead and arsenic then we can completely disable the RO and use UV + UF.
filter me bohot jyada mitti fasne se water flow kam ho jata hain. Pehle to app is video me dikhaye gaye tarike se cleaning kar lijiye. ua-cam.com/video/Pkt8ooiyghE/v-deo.html 90% problem solve ho jayega.
"karta hoga shayad" iska matlab kya hai are jab khud ko patta nahi kon sa switch hai kya kam karta hai to bekar mein public ko adhura gyan kyu baat rahe ho... pehele khud jan lo kon sa filter kya kam karta hai, konsa switch kya kam karta hai, kis tarhe se flow workout karta hai .....
Thank you so much it was very helpful during the Lockdown. A month ago my Kent RO became non functional and due to Lockdown engineers were unable to come over and fix. Came across your video I followed it throughout and my water purifier is working perfectly. Thank you and God Bless you 👍🏻👍🏻👍🏻🙏🏻🙏🏻🙏🏻
It's our pleasure. Thanks for watching,🙏🙂
Really helped when I completely unassembled to thoroughly wash and disinfect body and tank.
Wow. Thank for watching and subscribing
Sir booster pump se direct apne carbon filter me connection kr diya kya ye sahi tarika hai plz reply sir
Sediment filter aur uske baad in line Carbon filter
Sir, Mere kent ro me power on nahi ho raha h... Kya SMPS faulty hoga ya kuchh aur??
Agar SMPS kharab ho gaya hoga to board pe laga hua red light chalu nahi hoga.
2. Ya Kabhi kabhi motor bhi kharab ho sakti hain
Valuable information bro on right time 😍
Thank you so much for appreciation and support.
Really helpful information thank you.
Glad you liked the video. thanks for watching and subscribing to smartdrive333.com
Mere red light jalti hai after 3 minutes. Then works well . Before one month their mechanic replaced 3 filters and one outsise sediment filter. Moistures are accumulating inside the box of filter.Why it is taking 3 minutes before startnig? Pl reply.
One of the filter or pipe creating congestion in water flow. You need to raise the complaint to solve this issue.
@@SoneriVishwa you have told rightly . Again I have replaced the outside sediment filter and the problem has been solved.Thank You.
Our pleasure to serve you sir. Thanks for watching and subscribing 🙏😊
Sir ji Kent grand plus mai two sonolet velb use keya gaya hai one use pump and one use rejection water...? Jo samjha mai nahi aa raha hai
Ok. Let me check and revert
One Solenoid Valve is For Controlling Of Raw Water
And Second Solenoid Valve for Auto Flushing Purpose...
Ye kent ka konsa model hain?
Kent prime TC 2017
Hello, mera kent RO kaafi old model hai, usme membrane, sediment, carbon & UV hai, kya mujhe UF lagana chahiye?
RO hain to UF ki utni jaroorat nahi padegi.
UF dirty water ke liye jyada faydemand hota hain. Aap pre filter laga ke ye process refine kar sakte hain.
@@SoneriVishwa ok sir thanks
Meine bahar pre filter bhi lagaya hua hai
Aap bolte hai na ki TDS adjuster k karan tap wala pani bhi aa jata hai, to kya UV k baad jo peene wala paani aata hai, usse pehle UF lagane ki jarurat hai?
Nahi. UF sabse last lagta hain
Sir uf fillter kha fitt krna hai ye btaye
Tank main jo pipe ja raha hain usse pehle
Thanks this good information
🙏
can u tell me iska after buy cost kitna hai filter kits ka? kitne pani filter karne ki bad kis kis filter ko change karna hota hai? and uska price kitna hai?
normal filters Rs.500 RO filter Rs.2000/- fitting and visiting extra at actual.
filter change 5000liters.
Very helpful presentation
🙏
Sir maine suna hai ki Pump ka output membrane me diya jata hai magar apne carbon filter me diya hai aisa kyu sir
Pump ka output carbon aur RO dono ko diya jata hain. Same pressure ke saath. Agar aap gaur karenge to carbon inlet par ek T-joint hain. So dono ko sath me hi paani milega
Sir agar mai sediment uske bad carbon uske bad sv uske bad pump uske bad ek T lagakar TDS controller me aur ek membrane ke inlet me agar is tarah ka connection kre to membrane ka life kam ho jati hai kya aisa v kooch hota hai kya plz clearify kro ap sir @@SoneriVishwa
Surely effect hoga. Filter ki life 2 chije decide karti hai .
1. Water quality
2. Water flow
Agar paani kharab hain aur acchese flow nahi ho raha hai. To filters kharab ho jate hai.
Connections m koi bhi badlaw n kare. Isse pani ki quality me issues aa sakte hain.
thanks 👍
Glad you like the video.
Thanks for watching and subscribing to sonerivishwa
Thanks
Thanks for appreciating and supporting to vishwajeet.org
2nd one is SV(solenoid valve)
3rd one is TDS controller 🙏
Thanks for valuable details we will share this in upcoming episode.
Sir thanks. SV jise 24 volt
DC diya red & white wire se but agr SV m yellow and blue wire h to kese + P -- N judge kre please sir abhi btaanaa mene connection krna h DC ka
sir, electrical wiring or sensors ko na cheda jaye to hi behtar hain.
membrane replace kitne dino me hoti h aur sare 5,6 parts change krane me kitna rs padega?? please reply
Membrane replacement ke liye ek alarm laga hua hota hai. Wo alarm chalu hone ke baad filter band rehta hain jab tak aap servicing nahi karwate.
2. Totally 6000 tak kharch aa sakta hain.
Membrane ki life Apke ground water ke TDS(Total Dissolve solids in water) pe depend Karti hai agar TDS level jyada h to membrane jaldi choke(block) ho jati hai 🙏
90% membrane choke (block) Hoti h pre-filter ki wajah se Jo Apke R O k pehle LAGI Hoti h, pre-filter jam hone. Ki wajah se dust particles membrane tak pahuch jate h jiski wajah se membrane block ho jati h 🙏
thank you for your valuable insight. We are glad that this video helped you. Thanks for appreciating and supporting to vishwajeet.org.
Sir can we connect the uf membrane output water with ro membrane output to uv lamp without the control valve back side the uf
membrane
Please reply sir
We can but this type of modification is never done by me. Control valve is necessary to control wastage water also.
@@SoneriVishwa thanku sir
We are glad that this video helped you. Thanks for appreciating and supporting to vishwajeet.org.
saved me thanks
So glad that you liked the video.
Thanks for supporting and subscribing Sonerivishwa
Uf memberans filter bypass kise karte hai
Uf fliter bohot important hota hain. Use bypass karna recommended nahi hain.
Good presentation
Glad you like the video.
thanks for watching and subscribing.
7 liter tank full home me Kitna time lagta hai?
वो सेटिंग पे निर्भर करता है.
पर फिर भी 20 से 30 मिनिट मे tank full होता है
Sir mera more than 3 hour lagta h kya kre plz bataye. ?????
आपके पाणी का tds कितना दिखा रहा है ? ua-cam.com/video/66QnIh14R50/v-deo.html
TDS Controller is not an ideal way to add essential minerals in the purified water.100% of the input water does not pass through the RO membrane.
Mixing RO purified water with non-RO purified water may result in the presence of several harmful heavy metals like lead and arsenic in the purified water, as these impurities can only be removed by an RO membrane.
Thank you for such a valuable information.
Yes u r right we have to use active mineral filter to improve TDS level in water not rejected water of RO membrane 🙏
Thanks for watching and subscribing to vs.vishwajeet.org.
if we get our water checked and are sure that water is not having harmful heavy metals like lead and arsenic then we can completely disable the RO and use UV + UF.
Yes sir. Then RO is of no use.
Please help my kent grand plus ro purifier is producing dhaakkk sound what will we do
Check for any blockages. See if pump working properly. RO needs pump to operate.
Meraover flow sensorlight off honey key baad drop lagaataar girta hay kya karey
Outlet pipe ko jo valve bithaya hain wo gadbad hain. Use change karna padega
👍
Thanks for watching and subscribing to vs.vishwajeet.org.
Is video mai one hi sonolet velb use keya gaya hai
Thank you for your valuable insight. Thanks for appreciating and supporting to vishwajeet.org.
Hello sir app Kent ro assemble kanai wali video banai with full detail wiring
We will try
Controller Nahi LPS hai Low pressure switch 🙏
Thank you for your valuable insight. Thanks for supporting to vishwajeet.org
Bhai Parts ke name ye h - SV , TDS controller, FR,
thanks for your support and subscription.
Please wiring diagram bataye uv aur 24v.adupter
Mujhe thodj study karni padegi. Jaldi hi naya video post karenge.
😁😁
Thanks for watching and subscribing to sonerivishwa.
Shayad ?
100% correct hoga tab shayad nahi bolte.
फिल्टर के अंदर के पार्ट के बरेमे आप कॊ कम जाणकारी है. हार चीज कॊ शायद होगा ऐसे बता रहे हो.
हां. सही बात है. मैं जितना जनता हू उतना ही बता पाऊंगा. केंन्ट के सर्व्हिस वालो से थोडी जाणकारी ली थी ऑर बाकी याहा वाहा से.
Hello sir .
Hi
Bhai shayad se bat nahi bnegi
it's our pleasure sir.
thanks for watching and subscribing.
कहीं ना कहीं UV लाइट के connection me आप confuse hein.
Aap please bataiye kya details include karne jaroori hai. Hum usko agle video me cover karenge
भाई आधे से ज्यादा गलत जानकारी है,अच्छे से पहले पार्ट्स के नाम एवं काम जान लो फिर जानकारी देना,मुझे लगा इसलिए बोल दिया अन्यथा दिल पर मत लेना🙏
आपकी सुझावों पर हम जरूर काम करेंगे और नया वीडियो जल्दी ही लॉन्च करेंगे ।
@@SoneriVishwa जी सर👌🙏
🙏
Memberans filter fat gaya hai aur pani ka follow Kam hai
Apko filter replace karna padega
IED problem
Kindly elaborate more about your issues।
My kent kent grand plus ro alarm is not ringing when filter is not working
it's our pleasure sir.
thanks for watching and subscribing.
You are moving it so fast...
Please let us know which part of the video needs more detailed explanation.
We will post it in next few days
Mera kent ruk ruk kar chal raha he 2-2 sec me ruk jata he kya kare
filter me bohot jyada mitti fasne se water flow kam ho jata hain. Pehle to app is video me dikhaye gaye tarike se cleaning kar lijiye.
ua-cam.com/video/Pkt8ooiyghE/v-deo.html
90% problem solve ho jayega.
Saayad
Thanks for watching and subscribing to SoneriVishwa
Dubara kbi video mt bnana bhiya pLease 🙏
?
Sorrymera inland clear ni hua
Please call service center. Once you observe the process they do. It will be much easier.
"karta hoga shayad" iska matlab kya hai are jab khud ko patta nahi kon sa switch hai kya kam karta hai to bekar mein public ko adhura gyan kyu baat rahe ho... pehele khud jan lo kon sa filter kya kam karta hai, konsa switch kya kam karta hai, kis tarhe se flow workout karta hai .....
Oh
Tumse jyada knowledge hai apna gyan apne pass rkho smjhe behuda insan
@@SoneriVishwaAp sb sahi batate ho thnks bhai jan ❤❤
Sayad mat boliye pehle apne doubts clear kar lo tab hume batana
Dekhne ke liye shukriya