Mini Split Ac Outdoor 6 & Indoor 4 Wiring Connections

Поділитися
Вставка
  • Опубліковано 22 тра 2023
  • In this comprehensive UA-cam video, we provide a step-by-step guide on how to make the necessary wiring connections between the outdoor unit (Outdoor 6) and the indoor unit (Indoor 4) of a mini split air conditioning system with diagram. Whether you're a DIY enthusiast or an HVAC or Ac professional, this tutorial covers everything you need to know. We explain the importance of each connection, demonstrate the correct wiring techniques, and offer helpful tips to ensure a successful installation. Stay cool and comfortable this summer by watching our informative video on Mini Split AC wiring connections!
    ******************************************************************************
    Products You Might Be Interested to Buy
    Multimeters
    NEOTECK Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dml...
    ANENG Q1 Digital Multimeter ➡️ s.click.aliexpress.com/e/_DeU...
    Digital Pen Multimeter ➡️s.click.aliexpress.com/e/_DkM...
    Rechargeable Smart Multimeter ➡️s.click.aliexpress.com/e/_DDm...
    UNI-T UT181A True RMS Auto Range Multimeter ➡️ s.click.aliexpress.com/e/_DFL...
    ANENG 616 Large Screen Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dln...
    TOOLTOP ET8135 True RMS Multimeter ➡️s.click.aliexpress.com/e/_DB8...
    MASTECH MS8910 Digital Multimeter ➡️ s.click.aliexpress.com/e/_Ded...
    ZOYI ZT-X Digital Multimeter ➡️ s.click.aliexpress.com/e/_Dd9...
    ANENG Q1 Digital Multimeter 9999 Analog Tester ➡️ s.click.aliexpress.com/e/_DEz...
    Thermal Camera
    UNI-T UTI260B HD 256X192 Thermal Camera ➡️ s.click.aliexpress.com/e/_Deo...
    TOOLTOP ET692Cl Thermal Imaging Camera ➡️ s.click.aliexpress.com/e/_Dm0...
    Mileseey TR120E Infrared Thermal Imager ➡️ s.click.aliexpress.com/e/_Dej...
    Fluke TiS55+ Thermal Camera 9HZ ➡️ s.click.aliexpress.com/e/_DCO...
    Noyafa NF 522 523 Handheld Infrared Thermal ➡️ s.click.aliexpress.com/e/_DCe...
    TOOLTOP T7 256*192 Android Thermal Imager ➡️ s.click.aliexpress.com/e/_DmB...
    Soldering Wires
    10Pcs 2mm XZZ-2015 Desoldering ➡️ s.click.aliexpress.com/e/_Dkg...
    0.8mm/1.0mm 50g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDn...
    0.6/0.8mm 50g/100g Lead Free Solder➡️ s.click.aliexpress.com/e/_DDC...
    200g 500g Tin Wire Soldering Wire ➡️ s.click.aliexpress.com/e/_DdQ...
    8g 50g Per Roll High Purity Soldering Wire➡️ s.click.aliexpress.com/e/_DCm...
    250m/roll 30AWG UL1423 Insulation Cable Copper➡️ s.click.aliexpress.com/e/_Deu...
    Vacuum Pump
    18V Lithium Battery Vacuum Pump ➡️ s.click.aliexpress.com/e/_DDK...
    VEVOR 2.5CFM Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkT...
    Refrigerant Vacuum Pump ➡️ s.click.aliexpress.com/e/_DkH...
    VEVOR 1.8-4.8CFM Refrigerant Vacuum Pump➡️ s.click.aliexpress.com/e/_DeA...
    Mani Fold Gauge
    Digital Manifolds Refrigerant Gauge ➡️ s.click.aliexpress.com/e/_DC3...
    R410A R22 R134a R404A Manifold Gauge ➡️ s.click.aliexpress.com/e/_DeB...
    Refrigerant pressure gauge ➡️ s.click.aliexpress.com/e/_Ddg...
    500/800PSI Refrigerant Manometer ➡️ s.click.aliexpress.com/e/_Dne...
    HONGSEN HS-330 Refrigeration Vacuum ➡️ s.click.aliexpress.com/e/_DBi...
    Air Condition Gauge Manifold ➡️ s.click.aliexpress.com/e/_DFu...
    MRCARTOOL L202 Air Conditioner ➡️ s.click.aliexpress.com/e/_Dkg...
    Soldering stations
    RF4-H2 Automatic Sleep SMD ➡️ s.click.aliexpress.com/e/_DBa...
    JCD 2 in 1 Soldering Station LCD Digital Display➡️ s.click.aliexpress.com/e/_DFz...
    GVDA New Soldering Station ➡️s.click.aliexpress.com/e/_DDc...
    JCD 8586 Soldering Station 2 In 1 Digital➡️ s.click.aliexpress.com/e/_DBX...
    SUGON T21 Soldering Station ➡️ s.click.aliexpress.com/e/_Dne...
    AIFEN A5 Pro Soldering Station ➡️ s.click.aliexpress.com/e/_Dns...
    JCD 750W 2 in 1 Soldering Station LCD Digital➡️ s.click.aliexpress.com/e/_Dl1...
    UYUE T210 Soldering Station LED Digital➡️ s.click.aliexpress.com/e/_DeI...
    Soldering Stations MECHANIC➡️ s.click.aliexpress.com/e/_DmW...
    Desoldering pumps
    LUXIANZI 30w/40w Powerful Electric Desoldering ➡️ s.click.aliexpress.com/e/_DkV...
    Desoldering Pump Suction Tin Gun ➡️ s.click.aliexpress.com/e/_De1...
    110V/220V Electric Tin Suction Sucker Pen ➡️ s.click.aliexpress.com/e/_Ddu...
    Gaqqee 220v 36w Electric Solder ➡️ s.click.aliexpress.com/e/_Dkg...
    ******************************************************************************
    💡 Support Us On Patreon 👉 bit.ly/3vMga6S
    💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
    Social Links
    💡Facebook 👉 / forevertech3
    💡Instagram 👉 / forever_tech1
    💡Twitter 👉 / forevertech3
    #ac #airconditioner #minisplit #outdoor #indoor #connection #wiring

КОМЕНТАРІ • 28

  • @energyrecoveryinc.1157
    @energyrecoveryinc.1157 10 місяців тому +13

    Finally got it up and running. The only delays we had was because we realized we needed some extra parts (I’ll list that below) ua-cam.com/users/postUgkxihMYiJNXcHdbH-7ihymsLz61l7jVyb5O . So we have a loft where our current hvac just couldn’t seem to keep cool during the summer. We have been using a window unit since we bought this house over 6 years ago (all the houses in this neighborhood were built in the 80’s and majority of the houses built like ours use a window unit). I hate window units because they are just so noisy and the one we had really only cools one side of the loft. I had contemplated upgrading our current HVAC, but with all the rising prices these days, it would take years before saving up enough to do that. With the advice of my father-in-law (used to run an HVAC business), he recommended we get an inverter instead. We thought we bought everything we needed, but there were just a few other parts we didn’t anticipate needing (which is what caused most of our delay). My friend and father-in-law did all the work to get it installed and running and now we have nice cool air circulating nicely throughout the entire loft. It is very quiet and even the outside unit is much quieter than our main HVAC unit. Saved ourselves thousands getting this.

  • @vincyman80
    @vincyman80 26 днів тому

    Very interesting am so happy I found this.

  • @noside8469
    @noside8469 3 місяці тому +1

    Thanks... from the PH 🇵🇭

  • @antoniocarmona215
    @antoniocarmona215 11 місяців тому +2

    I LOVE YOU MEN!!

  • @FunnyBoyz-ec2he
    @FunnyBoyz-ec2he 2 місяці тому

    Very good 😊

  • @jashimuddin7355
    @jashimuddin7355 11 місяців тому

    Nice 👍👍

  • @florantetorres4664
    @florantetorres4664 7 місяців тому

    How to work or magnetise the relay by means of some device the control thermostat.

  • @HakeemKhan-tq8sg
    @HakeemKhan-tq8sg 4 місяці тому

    good 👍👍👍 good 💯 💯👍

  • @IAmThe_RA
    @IAmThe_RA 2 місяці тому

    Is it on a 16A or 20A dedicated circuit?

  • @riddik011
    @riddik011 10 місяців тому

    On outdor l and n are power suplay. You ther conect from grid

  • @marcsmithsonian9773
    @marcsmithsonian9773 Рік тому +1

    Four times six is twenty six. Connect every secon wire and it should be ok. Use shorky diodes and change your day from negative to positive.

  • @Mixolixplosion
    @Mixolixplosion 2 місяці тому +1

    Is it possible to feed the indoor unit first even if it does not have the L&N terminals? (So, What i would do is connect the main L&N directly to the 1L and 2N terminals of the indoor unit and the rest of the wiring will be the same as the video except that the L&N terminals of the outdoor unit will be vacant).

    • @forevertechenglish
      @forevertechenglish  2 місяці тому +1

      Yes it is possible to wire the indoor unit first, the unit works ( The way you do it still works. The L1 and N2 has a jumper wires attached with L and N. That is the reason the outdoor circuit powers on) , But always Remember that L & N are always the main power supply for the unit . The best practice is to wire the Main power on the L and N terminals. The L1, N2 and Signals or communication (S) terminals are used for the communication between the indoor and the outdoor unit.

    • @Mixolixplosion
      @Mixolixplosion 2 місяці тому

      Thanks. So, there is continuity between the respective terminals even when the power is off, right? I wish the manufacturers provided the same number terminals on the indoor unit as on the outdoor unit so that we have the options in connecting the supply to the units.

  • @cvaryan9225
    @cvaryan9225 День тому +1

    Hello,
    If the signal wiring not connect from indoor to outdoor
    What will happen

  • @tesfahungetahunargachew4328
    @tesfahungetahunargachew4328 Рік тому +1

    Tnx tnx a lot sir but I asked you to answer me types of refrigerator and the cooling process

    • @forevertechenglish
      @forevertechenglish  Рік тому

      I had answered it in one of the comment you asked..

    • @forevertechenglish
      @forevertechenglish  Рік тому

      Let me answer you again, There are two types of refrigerator in terms of cooling. The one is direct cool and the other is No frost.
      Direct cool refrigerators use a natural convection process for cooling, without the aid of any fans or other mechanical devices.
      No Frost refrigerators, also known as frost-free refrigerators, operate using a different cooling process compared to direct cool refrigerators. The main difference lies in how they prevent the buildup of frost and ice inside the freezer compartment.

    • @kareemhameed4042
      @kareemhameed4042 Рік тому

      Sir, Thanks for this video.
      On one of your last videos, you promise to do a video about refrigerators condenser calculations. I ask you a question on how to get an actual calculation of condenser if for instance, you are a changing a fridge with a compressor of r134 of 1/5 with another of r600 of 1/6size. Do I need to add up the condenser or reduce it to get similar cooling capacity like the r134a?

  • @user-iz6fv7hm8o
    @user-iz6fv7hm8o 10 місяців тому

    Hello,
    I have the same connection on the outdoor unit but the indoor unit has the connections L N S and ground wire. How to make the connections in this case?
    Thanks

    • @forevertechenglish
      @forevertechenglish  10 місяців тому

      Means the main electricity of your air conditioner is from the outdoor, you will probably see main L and N on the outdoor connected with your electric socket, and the other three would be L N S which will be connected to indoor.

    • @user-iz6fv7hm8o
      @user-iz6fv7hm8o 10 місяців тому

      I made the following connections
      On the outdoor unit I have W 1L 2N S L N
      The L N from outdoor unit goes to main socket.
      The 1L 2N S from the outdoor unit are connected to L N S of the indoor unit.
      Unfortunately appears a connection error between units (E1). The indoor units works but the compressor from the outdoor unit won't start!!.
      Thank you for helping me!

    • @user-iz6fv7hm8o
      @user-iz6fv7hm8o 10 місяців тому

      ​@@forevertechenglish
      I made the following connections
      On the outdoor unit I have W 1L 2N S L N
      The L N from outdoor unit goes to main socket.
      The 1L 2N S from the outdoor unit are connected to L N S of the indoor unit.
      Unfortunately appears a connection error between units (E1). The indoor units works but the compressor from the outdoor unit won't start!!.
      Thank you for helping me!

    • @user-iz6fv7hm8o
      @user-iz6fv7hm8o 10 місяців тому

      ​@@forevertechenglish
      Problem solved. I made a bridge between w and 1L at the outdoor unit for the connections from the indoor unit to t