Eicher लौंग क्रैंकिंग और इंजन बंद हो रहा है Eicher Long Cranking and Engine Shutdown 🤔 1075 Bs4 Bus

Поділитися
Вставка
  • Опубліковано 2 лис 2024
  • Eicher लौंग क्रैंकिंग और इंजन बंद हो रहा है Eicher Long Cranking and Engine Shutdown 🤔 1075 Bs4 Bus
    Eicher bs4 1075 Bus
    Long cranking
    Engine shut down in every 2-3 km
    Start after pumping
    After cheking by diagnostic tool we found that Rail pressure was decreasing running after 2-3 km
    then checked fuel line and filter
    then after down fuel tank
    then we found fuel stanier was choked
    after cleaning vehicle is running in good condition