Eicher लौंग क्रैंकिंग और इंजन बंद हो रहा है Eicher Long Cranking and Engine Shutdown 🤔 1075 Bs4 Bus
Вставка
- Опубліковано 2 лис 2024
- Eicher लौंग क्रैंकिंग और इंजन बंद हो रहा है Eicher Long Cranking and Engine Shutdown 🤔 1075 Bs4 Bus
Eicher bs4 1075 Bus
Long cranking
Engine shut down in every 2-3 km
Start after pumping
After cheking by diagnostic tool we found that Rail pressure was decreasing running after 2-3 km
then checked fuel line and filter
then after down fuel tank
then we found fuel stanier was choked
after cleaning vehicle is running in good condition
Instagram :-
/ auto_tech_india_atoz
#Auto_Tech_India_Atoz
#Long_Cranking
#After_running_2km_engine_shutdown
Your queries
Eicher
Eicher motors
Eicher Bs4 bus
Eicher 1075 bus
Eicher motor
Eicher trucks
Gaadi me pamp marna pad ra h baar tab start hoti h
Diesel line cheak krwa lo bhai kr barr or agr bs 3 h to Fuel pump V
Good work
👍
Super knowledgeable video sir 🤩
Haii
🙏
Hii ham bas s parasan h
Kon si bus h Bus me kya problem aa rha h or model kya h bus ka..??
Mera gadi ka su clear he phir vi problem araha he
Eicher 10 50 bus BS4 kilometre kam dikha raha hai bus 100 kilometre Chalti Hai 90 kilometre dikhata hai
Update gear ratio and cheka physically VSS sensor
Kaha ka ha y
In side of diesel tank
Tank clean koi kare ga kya bhai???
Haa kisi v machanic ko bolo kr dega
Sir i want ur ph num,,aap ka num desakthe ho plz mera ek doubt hai eicher bs4 mein,,
Instagram pr puch lo bhai