@@WhiteboardMedicine I feel like I need to add it was before disposable vent tubing. We had to soak it in cidex, brush and then hang to dry in a heated dryer. Once that done it was packaged and sealed. Yuck !! Also learned to draw ABG’s in a glass syringe. We would heparinize the needles prior. Afterwards, the glass syringes were washed and dried. Double yuck !! This was before the hep B vaccine came out. How we didn’t all get Hepatitis I will never know.
If in volume control and you select a decelerating ramp pattern (which seems to be the recommendation) then the scalers look much different … more like what you would see if the patient was in pressure control. To piggyback off this, when in volume control performing an inspiration hold, should the ventilator be set to a square waveform flow pattern for the most accurate plateau pressure measurement?
***MECHANICAL VENTILATION SERIES***
Mechanical Ventilation - Comparing Volume Control to Pressure Control [Using Scalars]
ua-cam.com/video/paRPeo9sbA0/v-deo.html
Mechanical Ventilation - Pressure Control Mode [Pressure, Flow, Volume Scalars]
ua-cam.com/video/y5NKLMJsCNg/v-deo.html
Mechanical Ventilation Settings - PEEP, FiO2, Respiratory Rate, Tidal Volume, Inspiratory Pressure
ua-cam.com/video/gnfCg3RXtGk/v-deo.html
Mechanical Ventilation - Volume Control Mode [Pressure, Flow, Volume Scalars]
ua-cam.com/video/ISFRxcQwozM/v-deo.html
Ventilator Waveforms (Scalars) And Loops - Basic Concepts - Pressure, Flow, And Volume
ua-cam.com/video/8pKZ3XYCOio/v-deo.html
Ventilator Dyssynchrony - Flow Starvation
ua-cam.com/video/IiSfDFUvzYc/v-deo.html
Ventilator Dyssynchrony - Double Triggering, Premature Cycling, Breath Stacking, Short Cycling
ua-cam.com/video/_NKwOVPGrMk/v-deo.html
I graduated from a respiratory therapy program in 1985…almost 40 years ago. We were using the MA1-1 with the bellows 😂
Love it, thanks for sharing!
@@WhiteboardMedicine I feel like I need to add it was before disposable vent tubing. We had to soak it in cidex, brush and then hang to dry in a heated dryer. Once that done it was packaged and sealed. Yuck !! Also learned to draw ABG’s in a glass syringe. We would heparinize the needles prior. Afterwards, the glass syringes were washed and dried. Double yuck !! This was before the hep B vaccine came out. How we didn’t all get Hepatitis I will never know.
If in volume control and you select a decelerating ramp pattern (which seems to be the recommendation) then the scalers look much different … more like what you would see if the patient was in pressure control. To piggyback off this, when in volume control performing an inspiration hold, should the ventilator be set to a square waveform flow pattern for the most accurate plateau pressure measurement?
If a patient not getting there correct volume? How do you fix it? What are some ways to increase back there volume?
Can make videos on simv vc+ ,simv prvc
We will add these to the list!