Calculating Wire Ampacity.

Поділитися
Вставка
  • Опубліковано 15 жов 2024

КОМЕНТАРІ • 96

  • @ronaldkovacs7080
    @ronaldkovacs7080 Рік тому +1

    Explaining the code in conversational English…finally. Thank you so much.

  • @devinwellington7537
    @devinwellington7537 3 роки тому +4

    OMG thank you for this because i have been having a hell of a time finding good videos on this for the CEC...

  • @TheDJYosh
    @TheDJYosh 3 роки тому +2

    This has been insanely helpful despite me having the 2021 Codebook for my classes. You are a life saver, I might consider showing my teacher this.

  • @joshjose9128
    @joshjose9128 Рік тому +1

    This has been insanely helpful despite me having the 2021 Codebook for my classes. You are a life saver, I might consider showing my teacher this.Loved this video! thanks! we need more Canadian content!!!

  • @kieranregan8997
    @kieranregan8997 5 місяців тому

    btw this is by far the most helpful videos I have ever seen and helping me study for the red seal examination! thank you so much

  • @robertbalasabas
    @robertbalasabas 4 роки тому +3

    Hey man! How am I just learning about your channel now?!?!?! Solid work!

  • @sdab06
    @sdab06 2 роки тому +1

    I used this video to help with problems. Had to adjust rules used for the 25th edition slightly but this was spot on. Thank you for the video @Theelectricacademy

  • @maximkayarosh2316
    @maximkayarosh2316 3 роки тому

    Hello dear sir.
    My name is Max, i saw your video and i want to tell you thank you very much, you explained so well
    (i have a low level of English and i understood more than 90 percent of what you explained),
    Please believe me you one of the best teachers which i met in my education time
    (i have education from Ukraine and Israel i have bachelor degree electrician and electrotecnica)
    now i would like to pass an exam in Canada. If all teachers would explain as you may i would have a doctor's Degree.

  • @ezrahutchinson607
    @ezrahutchinson607 3 роки тому +3

    Loved this video! thanks! we need more Canadian content!!!

  • @arefmalihi4327
    @arefmalihi4327 Рік тому

    Thank you. It was extremely helpful and in a simple plain explanation. I appreciate your time on this subject

  • @jorgemichaeltejano8922
    @jorgemichaeltejano8922 2 роки тому

    Thank you chad! Im currently in my CEF class and almost given up right away since the explaination was quite different your way was simple and methodical.i hope i could get more videos from like this to follow your footstep.

  • @neilmittelholtz113
    @neilmittelholtz113 4 роки тому +1

    Thanks very much for doing these videos. I’m waiting to complete my final year of school and this will be my first year in the 2018 code book so these are very helpful.

  • @stevenpeet5009
    @stevenpeet5009 3 роки тому

    Good explanations, 4-004 broke my brain on first read and this really helped.

  • @davcot3675
    @davcot3675 4 роки тому +3

    I just did a free air job
    I ran 100 amp feeder to garage because the entire backyard was paved
    Basically to service mast with Ariel cable 2 hots neutral and aerial is ground

  • @MacMND
    @MacMND 8 місяців тому

    Thanks a ton! I missed 2 weeks of prints class and had trouble wrapping my head around the book, especially when calculating for multiple conductors with a higher ambient temp than 30 Celcius.

  • @s2enzo
    @s2enzo 3 роки тому +1

    great job I'm LEARNING and the best part I CAN PAUSE!!

  • @urielalba1973
    @urielalba1973 4 роки тому +2

    Im in California I like your video I hope you make many more Im traying to educate my self in the electrical field anthis is a great way to obtain a lots of knowledge thanks.

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому +1

      Glad you liked the video. Make sure you check out the rest of them and please let me know if there is anything you’d like to see added.

    • @tedlahm5740
      @tedlahm5740 4 роки тому

      Keep up your studies. Plenty of info on Utube. Good luck and enjoy.

  • @NelsonGomez-do5gp
    @NelsonGomez-do5gp 2 роки тому

    Excellent Explanatory for using the codes

  • @PhaseV
    @PhaseV 2 роки тому

    Hey Chad. 4-004 1)a) gives the spacing requirements for free air cables. Typically, individual conductors ran in a cable tray or unistrut rack (with appropriate spacing), are calculated per Table 1 or 3. I saw comments on tri-plex and O/H service. Neutral supported conductors are covered in Table 36 A and B, and the O/H Service side is not under CEC (Hydro sets those limits). Hope this helps some of the guys here.

  • @stevemc2984
    @stevemc2984 4 роки тому +2

    Ampacity is covered in Article 310 of the NEC, with the most used Tables in 310.15.Great videos, btw.

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому

      Steve McArthur thanks for the info Steve! I need to take an NEC course sometime

  • @186Soup
    @186Soup 3 роки тому

    This is a fantastic refresher. Especially with going through level 2 during covid.

  • @ramandeepsingh391
    @ramandeepsingh391 3 роки тому +1

    Thank you so much
    You are a greater teacher
    Please make some more videos on canadian electrical code 🙏🙏

  • @kaceyjones7694
    @kaceyjones7694 3 роки тому

    Incredibly helpful and great walk through on the example questions

  • @MyTheMinecraftGuy
    @MyTheMinecraftGuy Рік тому +1

    awesome video thanks man

  • @carsongauthier258
    @carsongauthier258 11 місяців тому

    You are a living legend

  • @jasonreisinger7785
    @jasonreisinger7785 3 роки тому

    Awesome! Currently doing my schooling for my FSR test. You explain the rules very simple and your examples are great. How about sizing the neutral, and cable tray conductor ampacity.

  • @ronaldkovacs7080
    @ronaldkovacs7080 Рік тому

    Thank you., I now know how to de rate conductors when there is more than one de rating situation occurs.

  • @gichaeoh4252
    @gichaeoh4252 3 роки тому +1

    in example 5, why did you calculate based on#2 wires instead of #8 wires? I will be confused if I meet the same type of questions as this.

  • @jasonh8542
    @jasonh8542 2 роки тому

    Do you plan on making any videos with the new CEC 2021 ?

  • @chadg6874
    @chadg6874 2 роки тому

    Watching this video makes me want to do work in Canada unfortunately it doesn't work too well to the NEC because everything is everywhere especially around ampacity

  • @aouesrachid7089
    @aouesrachid7089 2 роки тому

    Hi Chad,Thank you for the video

  • @kieranregan8997
    @kieranregan8997 5 місяців тому

    for example 5, there is 2 different kinds of cables with different kinds of temperature ratings, R90 & TW. you said the r90 has a 90degree rating and the. tw has a 60 degree rating? how do I know or where can I find what temperature ratings the cables have? is it in the code book or should it be known already?

  • @susanrustaie2225
    @susanrustaie2225 2 роки тому

    hi, thanks alot for the vidoe, my question is how come it says (base on ambient temperature of 30 degrees ) on Table 1,2,3 but then it divides columns to 60C, 75C and so on?

  • @4pfcarti792
    @4pfcarti792 Рік тому

    insanely helpful bro

  • @brimmedHat
    @brimmedHat 4 роки тому +1

    Hey Chad , thanks for the video! I've been going through the CEC again in prep for my license exam (I work out of Toronto). I've been sort of struggling to find clarifications or examples of the conductor sizing for larger single conductors and cables using the D8A through to D11B diagrams and tables (and their larger counterparts D17A-D17N) for direct burial, underground run, and raceway.
    Could you provide any suggestions or resources? I'm particularly trying to understand if the same derating factors for temperature and such (5A-5D) apply to these calculations.
    Thanks in advance, keep up the great content.

  • @rastapus7
    @rastapus7 4 роки тому +1

    I'm a first year airbrush and want to get something short and abridged as something to thing through and carry with me. I think I've seen the uglys guide in the states, is there an equivalent for Canada? Thanks, great videos.

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому

      Hmm. The closest thing to uglys in Canada is the handbook that comes with the code book I think. It’s a great idea though.

  • @neiljanvier7120
    @neiljanvier7120 2 роки тому

    This is awesome, my only question is how do you know that TW is 60"C??

  • @franciswhite419
    @franciswhite419 4 роки тому +3

    Skip to 1:40 to pass the intro and the two, yes two introductions.

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому +1

      Haha. Good point. I noticed that after I recorded it. Next one will be better I promise. In fact I’ll put in a time stamp where the content starts.

  • @denvercharlebois709
    @denvercharlebois709 4 роки тому +2

    Hey Electric is there a possibility you could give me some pointers on a few things for the electrical code book? I have a mid term test coming up in two weeks that is on voltage drop, pull box calculations and ampacity deration. I am scared shitless because i transferred into this program and kind of new to this whole canada electrical code book, and my professor is a bit of a hard tester.

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому

      What kind of pointers are you looking for? what program you in? What year are you in?

    • @denvercharlebois709
      @denvercharlebois709 4 роки тому

      @@TheElectricAcademy i'm, in electrical techniques which is a pre apprenticeship program at Fanshawe college in London Ontario. One of the problems that was posted regarding voltage drop went something like this. A 7200 watt water heater operates at 240 volts and is located 20 metres from the electrical panel. What is the minimum TW75 conductor permitted to be installed for service to the water heater @ 2 % voltage drop. Those questions like that are kind of confusing and not sure what table to go to first when solving it.

  • @brotheradam
    @brotheradam 2 роки тому

    does your tables include metric wire yet?

  • @Z1612
    @Z1612 2 роки тому

    Thanks for the video. Great service.👍

  • @abdualchaban5508
    @abdualchaban5508 Рік тому

    Thank you that was really helpful

  • @juliaherrick9278
    @juliaherrick9278 3 роки тому +4

    Used to work at a nuke plant. Free-Air is literally hanging the cables from the ceiling. We had to do it for temporary power. Except it wasn't always so temporary. The cables are Clove-hitch tied to beams and dangling.

  • @tedlahm5740
    @tedlahm5740 4 роки тому +1

    The larger the diameter of the conductor (copper) the more free electrons?
    One amp of current equals one coulomb of free electrons (6.24 times 10 to 18th) Thank You.

  • @9047
    @9047 4 роки тому

    Thanks for your video, I have a question. For ampacity of cables in cable tray, the CEC is clear, spacing > 100% cable diameter; 25%

  • @brianmcdermott1718
    @brianmcdermott1718 Рік тому

    Great info . Thank you.

  • @philtwomey6760
    @philtwomey6760 2 роки тому

    Can you clarify regarding the neutral , if you have 4C Teck cable when de-rating do you count 3 or 4 , as the 4th conductor is a neutral ?

  • @doualeh
    @doualeh 3 роки тому

    hi , im having a problem finding the answer for this question here .
    "Three 3-wire , single phase circuits are installed in a conduit passing through an area where ambient temperature is 60*C and connected to a piece of equipment with a maximum conductor termination temperature is 75*C . The conductor are No. 4 AWG RW90.
    "? T2 is 85A and 9 wires on T5C 0.70 = 59.5 A / T5A = 0.58x 59.5 = 34.51 A . On my MOD , it says the answer is 48.29A .

  • @stoloveje6144
    @stoloveje6144 2 роки тому

    Excellent video!!! I has helped me a great deal.

  • @lucasorgan8363
    @lucasorgan8363 3 роки тому

    Hey, I have a questions on a tap conductor wondering if you would be able to lend a hand?
    Thanks

  • @jesusm8081
    @jesusm8081 2 роки тому

    Nice video! What about the length?

  • @brotheradam
    @brotheradam 2 роки тому

    free air is when you carry it from meter ole to house in the air, or house to barn in the air, or the old style in very old homes where wires were on insulators and such.. technically, if you stable it to wood and do not cover the opening area it is free air

  • @espdjs
    @espdjs 4 роки тому

    Great Video! Im trying to find max allowable ampacity of a 24awg conductor, but Table 1 only shows 14AWG and larger. Any idea where I can find smaller guages (for alarm and telecom) in the CEC? Thanks!

  • @omargarad6774
    @omargarad6774 Рік тому

    amazing really thanks for sharing

  • @BaljinderSingh-pn1mm
    @BaljinderSingh-pn1mm 22 години тому

    I subscribed your channel sir ❤

  • @1upman
    @1upman 3 роки тому

    The LE/FE course deals with free air. In temporary installs for movies and concerts.

  • @bobmitchell4532
    @bobmitchell4532 4 роки тому

    I'm hooking up a 30 amp 110 volt outlet for a trailer which is just a little under 200 feet away from the panel. I'm trying to determine the size of wire to use. Can you help?

    • @ecospider5
      @ecospider5 4 роки тому

      10awg might be perfectly safe. conduit.site/tables/table-310.15-b-16.php?option=cu
      But the voltage drop would be excessive. So I would go with 8awg or even 6awg if you have anything that would not like the voltage fluctuations.
      www.calculator.net/voltage-drop-calculator.html?material=copper&wiresize=2.061&voltage=120&phase=ac&noofconductor=1&distance=200&distanceunit=feet&eres=30&x=60&y=13
      But I am not an electrician so take my advice with a grain of salt.

  • @shaminderkhokhar4434
    @shaminderkhokhar4434 2 роки тому

    THANKS FOR SHARING IMPOTANT

  • @anonymousperson4363
    @anonymousperson4363 3 роки тому

    If not in conduit, overhead raceways are typically free air.

  • @brixtar
    @brixtar 4 роки тому

    Very helpful. Thank you.

  • @BertskiThe3rd
    @BertskiThe3rd 4 роки тому +1

    Hey man id really like some help id your around. Reply here id appreciate it im a first year student and abit confusedp

  • @lawrencetinsley4115
    @lawrencetinsley4115 4 роки тому +2

    Running conductors on top of open ladder rack in a data room environment is considered free air

    • @TheElectricAcademy
      @TheElectricAcademy  4 роки тому +1

      Lawrence Tinsley Yeah. That’s definitely an example. Have you done it?

    • @lawrencetinsley4115
      @lawrencetinsley4115 4 роки тому +1

      @@TheElectricAcademy yes sir, for over 20 yrs, #6 - 750 mcm DC power distribution systems

  • @holynincompoop
    @holynincompoop 3 роки тому

    Free air applications are common on railway passenger cars and on locomotives

  • @Padredimitry
    @Padredimitry 4 місяці тому

    Thank you!!!

  • @brotheradam
    @brotheradam 2 роки тому

    final correction factor would probably be cable trays

  • @momon1828
    @momon1828 4 роки тому +1

    dose Canada use 60 hz

  • @belaskoflek3703
    @belaskoflek3703 4 роки тому

    triplex is free air, overhead feed to shop for example. Also hydro connections

  • @sobhan20
    @sobhan20 3 роки тому

    This helped

  • @lukehartle5600
    @lukehartle5600 3 роки тому

    you're the man Chad

  • @espressomatic
    @espressomatic Рік тому

    I'm not an electrician, but I've fixed hundreds of problems caused by electricians. Reading the comments in here it's no wonder why. This is all super basic stuff and the fact people are having issues with it leads me to think they're heading down an incorrect career path. If you don't know this stuff, you should look at becoming an inspector - many of those guys like just making stuff up on the fly.

  • @kyle3420
    @kyle3420 Рік тому

    I could be completely off on this one but when I think free air I immediately imagine those exposed triple copper busses on overhead cranes

  • @jonathanlake3885
    @jonathanlake3885 3 роки тому

    In the NEC. It’s 310.16

  • @tejsandhu12
    @tejsandhu12 4 роки тому

    Plz made vedio a in section 26 and 32 and 60 plz Thaks sir ..

  • @rastyrebwar784
    @rastyrebwar784 4 роки тому +1

    could you send me the book

  • @zareeftashfique8168
    @zareeftashfique8168 4 роки тому

    BCIT 🙌🏾

  • @thomasholmes7125
    @thomasholmes7125 Рік тому

    NEC section 310

  • @hjooy
    @hjooy 4 роки тому

    Just forget about AWG; just only think in mm2. Life gets much more simple...