Leica Traverse application for CS20 (or TS16-13-MS60 ): Intro Basic Settings (Video 1 of 4)
Вставка
- Опубліковано 22 лип 2024
- 00:00 Introduction and Overview of Traverse application, go over some important settings before heading to field to perform the Traverse
01:20 Prism and Carriers used in Traverse . Same height as Instrument for forced Centering option
02:40 GHM007 Height measuring tool to eliminate any vertical reading errors (1mm)
03:45 Leica circular prism overview to reduce angular and centering errors
05:00 Basic Setting is Captivate to review for Traversing- Select CONTROL jobs containing RTK pair of points
06:10 How to enter current temp and pressure for correct PPMs in field
06:40 Select Prism constant being used in Traverse
07:55 Traverse application settings -location of Traverse application on Main screen to access, create New Traverse and overview of Traverse settings and reporting
11:00 Tips for One Man traversing settings with single pole
11:30 Traverse and basic Geometry if using RTK pair to start control
12:15 Overview of the Traverse report, and view information generated for Quality control and reporting
Thanks so much for adding value to the larger surveying community with this video.
@ 6:26 did you say can or cannot be edited in Leica Infinity?
Sean, thanks for response- sorry the PPM info CAN be edited in Infinity, that is strong feature of using Infinity to edit PPM, instrument heights, rod heights and prism offsets, as well as setup coordinates and adjust traverse Infinity compliments the field data collector very well
That's a great report sheet, where can I get one?
Below is a link for some Format files, use the "1200 Appl" file, to copy put on SD or USB under CONVERT subdirectory then can go on CS20 -SETTINGS_TOOLS_TRANSFER OBJECTS -Format File (from SD to Int Memory)
drive.google.com/drive/folders/1YVPYq_ohauSiy0Xy77ZzcwPppv5PripN?usp=drive_link