Boiler MFT ll Master Fuel Trip

Поділитися
Вставка
  • Опубліковано 27 лис 2024

КОМЕНТАРІ • 22

  • @Deepak-qe3nz
    @Deepak-qe3nz Рік тому +1

    Isi type ka vedio bnaiye ❤❤❤❤❤❤❤

  • @Mayank14755
    @Mayank14755 Рік тому +1

    Thankyou so much sir..pls keep positing.

  • @ashutoshkumarpandey3099
    @ashutoshkumarpandey3099 8 місяців тому +1

    Check APH ,scaner Bcp ... metal Temperature...etc

  • @ankitagrawal7561
    @ankitagrawal7561 Рік тому +1

    Very good content

  • @nasimakhtar8657
    @nasimakhtar8657 Рік тому +1

    Thanks a lot dear Sir..

  • @Annkkiitttaa_
    @Annkkiitttaa_ 4 місяці тому +1

    Sir please make a Video for Auto loop of Boiler. like FW, Oxygen trimming. CMC if possible

  • @abhishekpandey8773
    @abhishekpandey8773 10 місяців тому

    Boiler and Turbine ke Protection pe detail video bna dijiye Sir With Parameters..

  • @Deepak-qe3nz
    @Deepak-qe3nz Рік тому

    Please upload on regular basis

  • @motive0507
    @motive0507 Рік тому

    Sir, could you please tell me about HORV(Heavy oil Recirulation valve) line
    .Sir,I heard about two Recirculation lines as short and long Recirculation valves.
    could you please tell me about their paths

    • @BhagwanSRathore
      @BhagwanSRathore  Рік тому

      The recirculating line has two path
      1 by recirculating the oil temperature (density)is maintained so the oil should not be stuck in the pipes (this is fully open/close line which should be closed when we need to take gun)
      2 To regulate the pressure at the gun nozzle its a inching valve can be open in percentage
      The

  • @samlastseen
    @samlastseen Рік тому

    The tripping logic
    < F.B. loss ? in this why < sign given?
    What is fire protection trip given?

    • @BhagwanSRathore
      @BhagwanSRathore  Рік тому

      F.B loss ka protection kabhi experience nhi kiya i need to ask someone from c&i if i find out i will intimate you but i think it is related to mft panel A.C supply or something related to that

    • @samlastseen
      @samlastseen Рік тому

      Sir aapne kaha video mein field breaker aur mere yaha kuch log batate hai fire ball

    • @BhagwanSRathore
      @BhagwanSRathore  Рік тому

      Not sure yet confirm krna padega muje iska kyuki sath me ac supply ka hai to syd field breaker se related bola hoga need to confirm it

  • @devivara1162
    @devivara1162 Рік тому +1

    Sir why N.P.S.H needed in pump???

    • @hopelove6001
      @hopelove6001 Рік тому +1

      To avoid cavitation.

    • @BhagwanSRathore
      @BhagwanSRathore  Рік тому

      It provides adequate suction pressure to avoid cavitation in pump

  • @Deepak-qe3nz
    @Deepak-qe3nz Рік тому

    Yhi chahiye tha sir