  • @lastestvideo4333
    @lastestvideo4333 2 роки тому +1

    Sir how to identify the which problem are external or internal

  • @momidimallikharjun7241
    @momidimallikharjun7241 3 роки тому +1

    Sir we will take m value converts the seconds but you take minits value. why sir

  • @TheS4akella
    @TheS4akella 4 роки тому +2

    Nice clear explanation

  • @jarupulatejapawar8108
    @jarupulatejapawar8108 2 роки тому +1

    Sir,
    your explanation is good👍

  • @rehansolapur5382
    @rehansolapur5382 2 роки тому +1

    sir, why u have taken mass flow rate in(kg/min) in heat tranfer equa of 1st problem?, we have to take it in kg/s

    • @VENKATQ
      @VENKATQ  2 роки тому +1

      On the same step mas flow rate is converted into kg/s

    • @rehansolapur5382
      @rehansolapur5382 2 роки тому

      @@VENKATQ love ur teaching sir❤

  • @suhaschaure7406
    @suhaschaure7406 2 роки тому

    how to calculate outer diameter if only inner diameter is given in tube

  • @17_sameer10
    @17_sameer10 Рік тому +2

    Sir mass flow rate kg /min mai hai ...usko ap ne kg/sec mai change nhi kiya ....last equation mai

  • @saathwikmjain1911
    @saathwikmjain1911 3 роки тому +1

    to find engine oil properties Tm=147 degree C should we do interpolation to find out the values?

    • @VENKATQ
      @VENKATQ  3 роки тому +1

      Yes..if u need exact answer do interpolation...else take nearest value...

  • @mayankmishra142
    @mayankmishra142 2 роки тому +1

    sir how did you calculate the value of cp

    • @VENKATQ
      @VENKATQ  2 роки тому

      Cp of water is a constant value...

    • @mayankmishra142
      @mayankmishra142 2 роки тому

      @@VENKATQ yes sir but on internet cp of water is given as 4182 J/KgC,thus got confused.

  • @antonymbepa7880
    @antonymbepa7880 3 роки тому

    hi can i please have the name of the book you are using

  • @spidygaming2219
    @spidygaming2219 3 роки тому

    What about...T.infinity valuse...where you use

  • @abhiramadala9864
    @abhiramadala9864 3 роки тому +1

    but we are getting length value as 4.83

  • @bhanukatakamsetti7105
    @bhanukatakamsetti7105 3 роки тому +1

    Sir why the perimeter of the tube is π (Do+Di)

    • @VENKATQ
      @VENKATQ  3 роки тому +1

      In Internal flow of non circular ducts the hydraulic diameter is 4A/P...
      Where P is the wetted perimeter...
      Annulus means the flow will be between two concentric tubes... so the outer surface of the inner tube and inner surface of the outer tube are get wetted...hence P = πDo + πDi...

  • @saisudharani107
    @saisudharani107 2 роки тому +1

    Where water values should be taken in data book

    • @VENKATQ
      @VENKATQ  2 роки тому

      in my version of data book it is available in page no 22...search around through index...

  • @Tomtemor91
    @Tomtemor91 Рік тому

    What book do you take the formula from?

  • @ravanraj4616
    @ravanraj4616 2 роки тому

    Well explainasion

  • @fishhushh4546
    @fishhushh4546 Рік тому +1

    Tqq sir

  • @kakumanunagarjuna4065
    @kakumanunagarjuna4065 3 роки тому +2

    For Nu value databook has not just 3.66
    It has 3.66+((0.0668(D/L)Re Pr)/(1+0.04(D/L)Re Pr))
    Please confirm me with correct equation
    I have exam tomorrow

    • @VENKATQ
      @VENKATQ  3 роки тому

      Don't get confused...it is 3.66 only...for the equation you ststed condition will be given in details...which will not be asked in examinations...

  • @nuzhatnawer3689
    @nuzhatnawer3689 Рік тому

    Thanks sir

  • @rabecamohammed9518
    @rabecamohammed9518 2 роки тому

    I got q = 6127.639 W at the end.

  • @spandanmisra4193
    @spandanmisra4193 Рік тому

    underdog