सेप्टिक टॅंक अगर ठीक तरीके से बनाया जाता है तो बरसो तक खाली करने या साफ करने की जरुरत नही होती है. सारा मटेरियल गल जाता है और पानी बनकर बाहर निकलता है.
Thanks sir ,...what a tremendous video covering each mini steps ...and I don't have doubt ..you have taken the reference from IS CODE it's fantastic , the difference between out let inlet pipe , water proofing, slope ,, everything is fantastic salute sir ...
Sir hamare yha toh bina chamber ke sidhe 8×10 ka brick tank hai toh woh sahi hoga kya kyuki woh abhi under-construction me hai agar kuchh modification krna ho toh kya krwa skta hu?
@@Asr129 Zameen me gaddha kar k 4drum fix kr lo'''',,,, 3rd drum 4th drum se 1.5inch upar, 2nd drum 3rd drum se 1.5inch upar, 1st drum 2nd drum se 1.5inch upar. Zameen me drum rakhne k liye. Sabhi ko connect kr do or pot se connect kr, 4th drum se drain pipe or gas pipe lga do. 20saal bhul jao.
Whatever video on septic tank I have seen in U tube this one is no doubt the best ever piece of an extraordinary explanation & illustrations ! Thank u very much.
Aapse ek baat poochhni thhi. Vastu consultant ne bataya septic tank mere south east direction mein hai (east facing house) jo haanikaarak hai according to vastu. Mere yahan public sewage line aa chuki hai. Toh kya septic tank band karwa ke direct main sewage line se connect ho sakta hai?
Sir apne jo vastu k hisaab se jagah btayi h wo thik se clear ni ho payi...pehle aap bol re h yaha bnwa skte h fir cross ka Nissan lga diya apne plz reply
Maim apne ghar construction kar rha hun aur abhi septic tank construction phase chal rha hai.Size wagersh sab thik hai lekin dikkat ye hai ki mera ek tie beam septic tank ke mdar se gujar rha hai..aur uska koi upy bhi nhi dikh rha mere engineer ke hisab se...To please bataye ki isse ghar ki strength main kami ayegi..G+1 construction ke liye... And also septic tank mere 4 colum ke hunch to hunch ban rha hain..Yani column ke sloping part to chor ke just touch kar rha hai uska base.aur aisa 4 column ke bich main ban rha hai septic tank..Issey column main koi dikkat ayegi silan ki eajah se..My tank is RCC..Aur mera tank sirf 2 part main divide hai...Any problems i may face due to that???..please reply
Septic tank के चारो कोने पर पिलर आ रहा है। But चारों का footing slab के 4ft नीचे है। तो क्या पिलर को कोई harm करेगा क्या plz reply। अगर कोई राय हो तो वो v बता सकते है🙏
Sir mera ek question hain reply jarur dijiyega kya hamlog bina septic tank ke bathroom bana sakte hain please reply. Septic tank ke jagah agar toilet ka pipe nali se jod de to sara waste nali mein jaayega kya aisa kiya ja sakta hain taki septic tank kavi na bhade or septic tank ko saaf karane ka tention bhi khatam ho jaaye. Please reply jarur dijiyega kya aisa kiya ja sakta hain ya nahi
@@myengineeringsupport thank you 🙏 sir reply karne ke liye. Sir please aap ek video banaiye sewerage line ke uppar or usko ache se explain kijiye video me please sir video jarur banaiyega 🙏🙏
Sir mai nya ghar bna rha hu jisme septic tank 4 pillers ke bich me aa rha h aur uska depth 8 feet h 12 feet length h footing uske actual depth se 10 inch niche kya ye thik h ya isme kuch changes karne padenge please replay sir
Sir septink tank bharne per jab tank ke Nichle surface se pani 3or 4 inch niche rahta hai tab jaker waste pani outlet pipe se bahar ata hai to isse tank ko koi loss ho sakta hai kya
Bhai please please reply Dena Mera septic tank Ke beech mese Lactrine aur bathroom ka deewal diya hu Charo side se 10 din ka deewal aur piller v hai Par beech me deewal h aur uske niche koi support nhi hai Lekin dhalai h 4se 5inch ka To kya septic tank ka roof tutega to nhi beech mese Tension me aa gya hu
Sir mere yaha to 6×6 ka bana rahe hai or depth 7foot hai or front right corner column se Mila d diwar septic tank ki or wo boring se 4 foot dur h bas, ye galat h kya ya me ghar k piche banwau, kyunki water tank hamara parking me bnega , pls reply sir kaam chal rha h abi septic tank ka, galat ban gya to dikkat ho jayegi
Hmre to paani bahut down hai 100ft pe nhi hai pathr hi niklta hai ... Mitti km waha pe tank kitna rakye .. ground se pakka krma hai ja kacha rehna dye ....
2D & 3D हाउस 🏡 प्लान, घर का नक्शा
बनाने के लिए 9996656740 पर व्हाट्सएप करें!
Join my telegram channel
t.me/yoursengineer
Charge kitna loge aap
बहुत बढिया👌 और सटीक जाणकारी उपलब्ध करी हैं l
🙏धन्यवाद
Thanks 🙏
अति उत्तम जानकारी धन्यवाद जी
आभार
Bohot bohot dhanywad apka.iss jaankari ke liye..wakei bohot mehnat ki hai Aapne ..
Thanks for compliment☺
Sir बहुत अच्छी जानकारी दी आपने बहुत बहुत आभार
My pleasure 🥰
❤ प्रणाम जी ❤
ओडिशा
Thankq sirr dil se aapka aapki ek ek video bhut wadiya hai sir bhut ache messge hai sbi video me
Thanks 🙏
Sir Aapne bahut achhi jankari di hai dhanyawad,
My pleasure
Acchi Jankari dene ke liye dhanyvad sar
Welcome 🤗
सेप्टिक टॅंक अगर ठीक तरीके से बनाया जाता है तो बरसो तक खाली करने या साफ करने की जरुरत नही होती है. सारा मटेरियल गल जाता है और पानी बनकर बाहर निकलता है.
Thank you sir aapne bhut acchi knowledge di
Bahut bahut dhanyawad Sir, sarthak jaankari ke liye
बहुत अच्छी जानकारी।
धन्यवाद !
Thanks
Bahot achchha jankari di sir aap ney Sukriya sir
Thanks khan sahab
Very good knowledge giving information
Thanks
Been mein send cement & concert ratio kiya rakhein Aapki knowledge se bhahut khush huya
1:2:4 minimum
Very correct information . Keep it up to to apprise the Aam Aadmi and work men related to building construction.
Thanks🙏
Excellent.. information.. thanks
My pleasure🙏
Nice information...👍👍
Thanks 🙏🙏
Fantastic presentation!!! 🤞👏👏
Thanks sir ,...what a tremendous video covering each mini steps ...and I don't have doubt ..you have taken the reference from IS CODE it's fantastic , the difference between out let inlet pipe , water proofing, slope ,, everything is fantastic salute sir ...
Jankari k liye bahut bahut dhanyavad.
Sabhi issue ko solve kar diya tq
Welcome
Bilkul sahi jankari he👌🏽👌🏽💐💐
Bhai nice video thank you
Welcome🎉
Sir hamare yha toh bina chamber ke sidhe 8×10 ka brick tank hai toh woh sahi hoga kya kyuki woh abhi under-construction me hai agar kuchh modification krna ho toh kya krwa skta hu?
Good demonstration.
Thanks🙏
बहुत अच्छी जानकारी
Best and extensively explained technically. Very few you tubers speaks so detail.
Thanks🙏
aq
aqq
Humne 500ltr k plastic drum use kiye h 4. 10saal me aaj tak clean ni kia, kbhi moisture ni aya. Or cost only 6000thousand with all over work.
Good
Kaha se ho bhai?
@@sksabirali2371 Agra, Uttar pradesh
6000 mein 4 drum ye kaise
@@Asr129
Zameen me gaddha kar k 4drum fix kr lo'''',,,,
3rd drum 4th drum se 1.5inch upar, 2nd drum 3rd drum se 1.5inch upar, 1st drum 2nd drum se 1.5inch upar. Zameen me drum rakhne k liye. Sabhi ko connect kr do or pot se connect kr, 4th drum se drain pipe or gas pipe lga do. 20saal bhul jao.
Thankyou so muchhhhhhhhhhh🥰🥰🥰🥰🥰🥰🥰🥰🥰
My pleasure 🥰
Jai Hind sir ji
Thanks for advice.👍
Welcome 🙏
Thankyou for your information
My pleasure🙏
I have not seen such detailed information so far on UA-cam
Jankare achche lage kuch baten rah Gaye seet length deep aur tank me extra paipe cleen ext.
Ok noted
Very good information. Thank you so much
Welcome🎉
Hi
Greate information sir 😍😍😍.
Thanks 🙏 bro
Nice information 👍
Thanks🙏
Whatever video on septic tank I have seen in
U tube this one is no doubt the best ever piece of an extraordinary explanation & illustrations ! Thank u very much.
My pleasure🙏
Nice information thanks a lot for such valuable information L N Sharma
व्हेरी गुड
Thanks alot🙏
Help full guidance. Thanks
My pleasure🙏
Very informative video
*It's very use full and knowledgeable, thanks with soft courtesy*
very good voice i was hearing with headphones
THANK YOU SO MUCH
My pleasure 🥰
Thanks you sir soak pit par bhi ek video banaye.
bahutt sundar sir
Aapse ek baat poochhni thhi. Vastu consultant ne bataya septic tank mere south east direction mein hai (east facing house) jo haanikaarak hai according to vastu. Mere yahan public sewage line aa chuki hai. Toh kya septic tank band karwa ke direct main sewage line se connect ho sakta hai?
Hi Friend So Useful Tips For Home Making Knowledge 👌 Thanks For The Suggestions 🙋
My pleasure🙏
Good Advice 👍💚
Nice tips
Thanks🙏
Sir ji ager saptic tank me ground level me pcc karne k bad zameen se pani aa raha h to kiya wo sahi hoga k nhi jawab ka wait rahega
Very well described
Thank you for very important information.
Welcome
Nice information sir
Thanks🙏
very good thanks for sharing the knowledge
Welcome 🤗
Thanks Good sajesan👍
Welcome🎉
Good video
Thanks 😊
❤ thank you
Super great sir
Excellent💯👍 superb
Thanks🙏
Very informative, thanks.
Glad it was helpful!
Sir apne jo vastu k hisaab se jagah btayi h wo thik se clear ni ho payi...pehle aap bol re h yaha bnwa skte h fir cross ka Nissan lga diya apne plz reply
सेप्टिक टैंक best location North West
Maim apne ghar construction kar rha hun aur abhi septic tank construction phase chal rha hai.Size wagersh sab thik hai lekin dikkat ye hai ki mera ek tie beam septic tank ke mdar se gujar rha hai..aur uska koi upy bhi nhi dikh rha mere engineer ke hisab se...To please bataye ki isse ghar ki strength main kami ayegi..G+1 construction ke liye...
And also septic tank mere 4 colum ke hunch to hunch ban rha hain..Yani column ke sloping part to chor ke just touch kar rha hai uska base.aur aisa 4 column ke bich main ban rha hai septic tank..Issey column main koi dikkat ayegi silan ki eajah se..My tank is RCC..Aur mera tank sirf 2 part main divide hai...Any problems i may face due to that???..please reply
Thank you Sir 🙏🏼🙏🏼
Welcome🎉
Jaberdast
Thanks🙏
Good advice
Thanks🙏
Sw side m bana sakte h, or fir kaha nahi banana chahiye plz clear kro
Thank you very much bhai
My pleasure✨
Septic tank के चारो कोने पर पिलर आ रहा है। But चारों का footing slab के 4ft नीचे है। तो क्या पिलर को कोई harm करेगा क्या plz reply। अगर कोई राय हो तो वो v बता सकते है🙏
Gas ke liye ventilation nahi hai or outlet pipe bhi nahi hai. Kya kya problems ho sakti hai? Please bataein.
very nice 👍👍👍
Nice information video...
Please septic tank ki *pdf ya ppt* provide kra dijiye..🙏
sir septic tank ko ghar sae maximum kitne dur me lagana thik rahega jisse pipe line jam hone ke chance na ho
Sir RCC S. Tank 13x7x7 mistery ka kitna pese hoga without material
Teen manzila bani hui imarat me coloumns aur beams dalne ka upay bata sakte hai kya
Yes
Sir mera ek question hain reply jarur dijiyega kya hamlog bina septic tank ke bathroom bana sakte hain please reply. Septic tank ke jagah agar toilet ka pipe nali se jod de to sara waste nali mein jaayega kya aisa kiya ja sakta hain taki septic tank kavi na bhade or septic tank ko saaf karane ka tention bhi khatam ho jaaye. Please reply jarur dijiyega kya aisa kiya ja sakta hain ya nahi
Yes agar apke area me sewerage line hai to aapko septic tank ki koi jarurat nhi hai
@@myengineeringsupport thank you 🙏 sir reply karne ke liye. Sir please aap ek video banaiye sewerage line ke uppar or usko ache se explain kijiye video me please sir video jarur banaiyega 🙏🙏
Nice post
Thanks dear
Sir mai nya ghar bna rha hu jisme septic tank 4 pillers ke bich me aa rha h aur uska depth 8 feet h 12 feet length h footing uske actual depth se 10 inch niche kya ye thik h ya isme kuch changes karne padenge please replay sir
Ok h
🇮🇳जय हिंद जय भारत🇮🇳
Vande matram
North or ,East facing makan me septik tank kis side me bnaye
Soop tank ka bari may ak video baniya please.🙏
Namaskar sar Sar Mera Sawal hai ki ham safety Tanki diwaron mein Pathar Ka istemal kar sakte hain kya kripya bataen
No
Kyun nahi kar sakte Sar ji batana
Sir informative video
Thanks🙏
I have query regarding the slope on floor of the septic tank. Do we need to keep upward slope on the inlet pipe side as shown in video?
Agar ham 6/10 ka tank banva rahe hain aur usmein teen chamber de rahe hain to theek padega sir
point 25-16:28 आप बोल रहे हो के... 5 by 9... और कभी बोलते हो के रुल नुसार lenght 3 गुना हो width के... Confusion हो गया ये तो
Check video properly
Sir हमारे घर मे दीवाल के नजदीक ही सेफ्टिक टैंक बगल वाला बनवा रहा है तो कोए दिकत होगी हमरव दीवाल में
No
Toilet me smell na aaye uske liye toilet seat ko septic tank se kaise connect kare. Pls bataye
P trap
can you share a plan drawing of septic tank concrete RCC 3 chamber
Sir septic tank ghar ke ander banwana ho to kya yahi method use karna hai
brick wala septic tank AAC block se bhi bana sakte ha kya?
Yes you can
Good
Thanks🙏
Hamare yaha briks ka seftik tenk banate he par usme plastar nahi karte,kiv ki pani jada sokhata he .kya ye sahi he
Sir septink tank bharne per jab tank ke Nichle surface se pani 3or 4 inch niche rahta hai tab jaker waste pani outlet pipe se bahar ata hai to isse tank ko koi loss ho sakta hai kya
No
@@myengineeringsupport thank you very much sir
Bhai please please reply Dena
Mera septic tank
Ke beech mese
Lactrine aur bathroom ka deewal diya hu
Charo side se 10 din ka deewal aur piller v hai
Par beech me deewal h aur uske niche koi support nhi hai
Lekin dhalai h 4se 5inch ka
To kya septic tank ka roof tutega to nhi beech mese
Tension me aa gya hu
Sir mere yaha to 6×6 ka bana rahe hai or depth 7foot hai or front right corner column se Mila d diwar septic tank ki or wo boring se 4 foot dur h bas, ye galat h kya ya me ghar k piche banwau, kyunki water tank hamara parking me bnega , pls reply sir kaam chal rha h abi septic tank ka, galat ban gya to dikkat ho jayegi
Namste sir ji.muje ye btao 15by30gaj mai saftik tank kitna bda bnaye
Family members?
7by10 feet.......... Height approx 8feet
Hmre to paani bahut down hai 100ft pe nhi hai pathr hi niklta hai ... Mitti km waha pe tank kitna rakye .. ground se pakka krma hai ja kacha rehna dye ....
Jha base strong ho wahi tak