Basic theory of Pneumatic cylinder’s Air consumption & Required air flow capacity

Поділитися
Вставка
  • Опубліковано 11 гру 2024

КОМЕНТАРІ • 15

  • @ibrafiqa5744
    @ibrafiqa5744 Рік тому +1

    This is GREAT. Commonly Actuator manufacturer already stated the Volume of Air on each model of Actuator. I hope that you can give us the video that will continue this to calculate or to choose the correct SOV, Regulator, Booster, etc. Because when I design the Pneumatic Control System on SDV, I have to look on SOV, QEV or Booster cv to get the correct stroking time.

  • @Dmsxj
    @Dmsxj Рік тому +2

    I have watched all the videos, and they are very well done. I am looking forward to the update of the video content!

  • @Worldfamousvlog1996
    @Worldfamousvlog1996 9 місяців тому +3

    please make video for air consumption in on-off valve & control valve

  • @f3nunez
    @f3nunez Рік тому +1

    nice and excellent

  • @kundanprasad2407
    @kundanprasad2407 Рік тому +1

    Nice explanation, thanks a lot for the video. 👏👏. Please make a video for compressor selection.

    • @MsPneumatic
      @MsPneumatic  Рік тому

      Thank you for your kind words. I will refer to it when selecting a topic in the future.

  • @kazuomikun
    @kazuomikun Рік тому +1

    I have a question, let's say you did this calculation process for 10 actuators in your system and then you get, for the sake of the example, 2500 L/min. This is actually a very large number (2.5 m3/min). The next stage is actually how to "downsize" the required air demand. Would it be based on a simultaneous use factor, and also on a utilization factor? for example of 0.15 and 0.2, repectively, giving then 75 L/min. We also need to consider the air receiver, isn't it?

  • @Dmsxj
    @Dmsxj Рік тому

    视频很好,期待更新!🎉🎉🎉

  • @Takalie_kontee
    @Takalie_kontee Рік тому

    Thanks for the knowledge, but I have a question.
    How do you know how much time the cylinder will take? 8:30

    • @kazuomikun
      @kazuomikun Рік тому +1

      It's usually stated on the data sheet of the acturator ;)

  • @democracyforthepeople2982
    @democracyforthepeople2982 Рік тому

    Hi
    Would you circulate
    Air consumption calculation to fill 1000liter to 100 psi through 50lpm compressor ( tank out let has 50liter tank)

  • @mangeshpaithankar8719
    @mangeshpaithankar8719 8 місяців тому

    In calculation why pressure has plus 0.1 and divide 0.1 please explain the conversation

  • @anggunrokhmatika4641
    @anggunrokhmatika4641 Рік тому

    how to calculate the tank consumsion

    • @hoonchoi9865
      @hoonchoi9865 9 місяців тому

      Thank you for your question. I'd like to suggest you to ask the tank air consumption to compressor maker.

  • @omnavghane5972
    @omnavghane5972 Рік тому

    try showing your face in your next video it will help audiance to interact properly and will also make you gain more subscriber and views