FIXING 24 VOLTS LOW INSULATION | Marine Electrician

Поділитися
Вставка
  • Опубліковано 18 лис 2024

КОМЕНТАРІ • 62

  • @Dilidjent
    @Dilidjent Рік тому

    Wow, the things you are doing for future generations are pure gold my friend. God bless you!

  • @eboytheeminent831
    @eboytheeminent831 3 роки тому +3

    I like your touch, this is amazing. It's such a great pleasure to be in a position to explore your career. Keep it up. Congratulations.

  • @adrianaberion8140
    @adrianaberion8140 4 роки тому +1

    Thanks, very informative, lalo na sa mga 3 A/E na walang kasamang electrician sa barko

    • @leckyjake
      @leckyjake  4 роки тому

      Thanks for the support

  • @PeaceMah
    @PeaceMah 2 роки тому

    You da man Jake. Bravo.

  • @johncantrell614
    @johncantrell614 3 роки тому

    Good work. I have to admit, that one probably might have stumped me.

  • @jeromewelch7409
    @jeromewelch7409 3 роки тому

    your an awesome diagnostician very methodical in your approach thanks for lesson.

  • @gavinofuedan2664
    @gavinofuedan2664 3 роки тому

    Superb Isolation sir

  • @reyvincentgumapac210
    @reyvincentgumapac210 3 роки тому

    Laking tulong to sir thank you po ngyon po ganito problema namin

  • @bertapartv
    @bertapartv Рік тому +1

    Very nice master

  • @shyster717
    @shyster717 3 роки тому +1

    Good material, I am also with Maersk. On Santa class unfortunatelly, when you have a 24VDC earth fault, there is an engine stop...but this fault must be only in engine control modules to let it happen.

    • @leckyjake
      @leckyjake  3 роки тому

      Just had on the ECU B 2 days back and good thing it was fixed immediately. I am doing this fault finding specifically for the MAN B&W engine.

  • @picachou8561
    @picachou8561 4 роки тому +1

    Galing talaga leck. Keep up the good work leck

    • @leckyjake
      @leckyjake  4 роки тому

      Thank you for the support

  • @viraltandel7769
    @viraltandel7769 2 роки тому

    please make video on DG sensors.. how to check & maintain well

  • @mohdkhaja2713
    @mohdkhaja2713 Рік тому

    Lot of thanks sir.
    I take knowledge from u

  • @senthilanbalagan8532
    @senthilanbalagan8532 4 роки тому +1

    Nicely explained great job

    • @leckyjake
      @leckyjake  4 роки тому

      Thanks

    • @charukagawesh2617
      @charukagawesh2617 2 місяці тому

      In our ship same problem coming , i switch off all consumers but the low insulation showing nearly 0. I switch off 2 chargers one by one but problem still same. Any advice ?

  • @denis_artemov
    @denis_artemov 4 роки тому +1

    Thanks for your great videos!

    • @leckyjake
      @leckyjake  4 роки тому

      Thanks for the support

  • @abdalrahembarham4343
    @abdalrahembarham4343 4 роки тому +1

    Thanks for your info Mr.lecky
    How did you test the sensor in DG control panel ?
    and can we start the generator if there was an earth fault in it ??
    Hoping you can answer my multi answer!!!

  • @MsPinks007
    @MsPinks007 3 роки тому

    Superb lecky sir.. waiting for your new trouble shooting videos...👍

  • @BroskiTheGreat
    @BroskiTheGreat Рік тому

    Outstanding 👏

  • @subhammondal6294
    @subhammondal6294 4 роки тому +1

    Nice video sir.
    Thank you very much sir.

    • @leckyjake
      @leckyjake  4 роки тому

      Thank you for the support

  • @kknk5072
    @kknk5072 9 місяців тому

    Thank you Sir.

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp 2 роки тому +1

    Thanks 👍

  • @arvinagullana6679
    @arvinagullana6679 4 роки тому +1

    Sir.. good day.. thank you for sharing your knowledge to us especially to those who are new to the work..
    Sir, kung okay lang.. pwd ba makahingi ng tips/ guidelines on how to recover during blackout. Bago lang po ako sir. Thank you sir and God bless

    • @leckyjake
      @leckyjake  4 роки тому +1

      Will keep that in mind. Magandang topic yan

    • @arvinagullana6679
      @arvinagullana6679 4 роки тому

      @@leckyjake thank you sir jake... God bless po

  • @kahar2011
    @kahar2011 4 роки тому +1

    Nice explain sir, thanks for your share..

    • @leckyjake
      @leckyjake  4 роки тому

      Thank you. Please like and share 😉

    • @kahar2011
      @kahar2011 4 роки тому

      I am electrician to, please follow my channel.. thanks

  • @dilipsangada6691
    @dilipsangada6691 4 роки тому +1

    Good morning sir from india

  • @ionaandshienahendwonderlan1904
    @ionaandshienahendwonderlan1904 2 роки тому

    Idol lecky tnx for sharing

  • @ScorpiomarineTV
    @ScorpiomarineTV 4 роки тому +1

    Goodpm sir leckyjake.. Mayroon ako case dito nah lowinsulation sa 24 V, nka zero ang insulation meter, P at N nag ilaw .pag ene earth test ko sya nag nonormal at infinity reading at ang namamatay na lamp indicatior ay ang N. Pag balik ko naman sa earth test switch sa normal position, mag zero at P N ang iilaw olit. Ang ginawa ko sa dc switchbaord namin, dhil may 2 breakers, (DC-A for navagitional equipments, fire alarms etc. at DC-B para sa Engine control console at main switchboard ) sa DC-A na inoff ko hindi sya nag normal, pero sa DC-B nung inoff ko nawala ang low insulation nag normal na.so doon ako SA panel board sa engine control room(DC-B)nka fuse na lng sila, 4 na fuse, ang 2 fuse ay para sa main switchboard positive at negative, at ang dalawa pang iba ay sa engine control console.. Tinanggal ko isa-isa ang positive fuse ng main switchboard, at engine control console. Wla parin,So tinanggal ko ang mga negative fuses. Sa engine control console wala parin nangyayari, pero nung ang negative fuse na tinggal ko sa main switchboard. Nwala na ang low insulation at nag infinity.
    1.)Engine control console(alarms indicators and anunciators)
    2.)DC Main Switchboard alarm (alarm circuit na may tatlong cards. Alarma Para sa low insulation 440,low insulation 100,preferencial trip at Emer. GEN. Eng. Abnormal at power ng lamp indicators sa emergency gen., (Emergency Gen. run, eng Abnormal at stanby ,
    nung tinggalan ko ito ng negative fuse saka pa nawala ang low insulation.Ngayun palang tu nagka low insulation 24v,kadalasan nmn dito ay 440v,100v.

  • @aveshgupta4252
    @aveshgupta4252 9 місяців тому

    Thank you 🙏

  • @adityaputra6747
    @adityaputra6747 Рік тому

    Hi Jake, this is pretty much helpful. i have question. but what if the alarm comes and goes, it just triggered for few second. and back to normal. how to find the source in this situation.

  • @ademothmen450
    @ademothmen450 Рік тому

    Some ship there is not existing 24 vdc inducator of fault insulation,how to know that? Is it from 220v inducator ?!

  • @fcgaylan
    @fcgaylan 3 роки тому

    You're the BEST !!!

  • @monzurhasan3583
    @monzurhasan3583 4 роки тому

    Thank you so much

  • @bt9604
    @bt9604 Рік тому

    When u connect the wire to gnd both the lights should dim, how only one did, since they are in series

  • @dshinkori
    @dshinkori 2 роки тому

    Good keep it up

  • @dreamoto7251
    @dreamoto7251 2 роки тому

    Sir Im a newbie in ship electrician , nag trouble po yung auxillary namin hindi na po ma auto yung gobernor nya,, pwede po ba pa advice kung ano ang dahilan nito at bakit ?
    Top fan nyo po ako sir

  • @dipakkumar-kk8zp
    @dipakkumar-kk8zp 4 роки тому

    Thanks dear

  • @ShubhamSingh-bn3vx
    @ShubhamSingh-bn3vx 3 роки тому

    What u were checking in those sensor? IR value???

  • @radhakrishna1008
    @radhakrishna1008 4 роки тому

    Plz make a video on power system on how 440V is converted and fed to 24V loads.. I mean from generation of 440V to different types (I.e. volts) of loads...

  • @DANI-ru3vt
    @DANI-ru3vt 4 роки тому

    Sir, I would like to ask one question. If you don't mind, please tell what are things are needed before joining the ship.

  • @jackpot7029
    @jackpot7029 3 роки тому

    Sir any idea about ang generator engine alternator, alarm low insulation 440v triggered when generator has a load, pag naka idle po wla naman alarm,...anu kaya possible problem and troubleshooting ?tanx

  • @joelsemblante3486
    @joelsemblante3486 4 роки тому

    Same sa kabayo ko dto sir 24v low insulation ang hirap hanapin kac intermittent yong alarm seconds lang mawala na both navigation at sa port susulpot...

    • @leckyjake
      @leckyjake  4 роки тому

      Sana ma kita mo ang fault

  • @noblehormeku7326
    @noblehormeku7326 2 роки тому

    i will like to work with you one day on a ship one fine day kudos to you

  • @johnandes8861
    @johnandes8861 4 роки тому

    Sir Jake san po kaya maganda magtraining about sa marine electrical. kakatapos ko lang isang contrata ko as wiper. gusto ko rin sana maginf eto gaya nyo REE at RME din po ako.

    • @FloroJrGaray
      @FloroJrGaray 3 роки тому

      Try mo UMTC,NTC,GIGAMARE...May trainee cadetship sila dun sir.

  • @manoranjan4598
    @manoranjan4598 3 роки тому

    Nice medam aur banaiye video realy ke baare me

  • @hafizanismujahid5375
    @hafizanismujahid5375 2 роки тому

    I cant understand..

  • @ManojYadav-or6tj
    @ManojYadav-or6tj 2 роки тому

    Hii sr

  • @alfrazernudalo1060
    @alfrazernudalo1060 3 роки тому

    😉