Cutting Length of Column | Footing to Plinth | Staggered bar in column | Non Typical

Поділитися
Вставка
  • Опубліковано 30 вер 2024
  • Hello Friends,
    I have explained in detail calculation of cutting length of column from footing to plinth level and adjusting staggered length of bar. Calculation of length of bars upto next floor and lap length of bar. I hope this video will be helpful to you.
    If you liked the video please give a thumbs up and share this video as much as you can with your friends.
    For more videos like this Subscribe to my Channel
    Connect with me on Instagram : furqan.zari
    Staircase checking on site
    • STAIRCASE CHECKING AT ...
    Primary beam and secondary beam connection
    • PRIMARY BEAM to SECOND...
    How Mahad Building collapsed?
    • How Mahad building col...
    Slab shuttering process shot on site
    • How slab shuttering an...
    3 Big Mistakes in Cantilever Beam
    • 3 Mistakes in Cantilev...
    Learn to read MEP sleeves Drawing
    • How to read MEP Sleeve...
    25 top selected practical civil engg questions
    • 25 Basic Practical Civ...
    Difference between stirrup and ties
    • Difference between sti...
    What is core cutting?
    • Is core cutting safe??...
    Column steel checking
    • CHECKING COLUMN REINFO...
    Design of two way slabs
    • DESIGN OF TWO WAY SLAB...
    DOUBTS CLEARED:
    How to calculate cutting length of column?
    How to calculate staggered length of column bar?
    How to calculate lap length of column?
    How to provide bar in confinement zone?
    #Column #CivilEngineering #BBS

КОМЕНТАРІ • 89

  • @EverythingCivil
    @EverythingCivil  4 роки тому +4

    Hello friends this a reupload as I missed some parts. I believe showing correct and legit content is most important therefore I :have corrected and uploaded again for you guys. It is from 4:53 to 7:32. Thanks for watching. Love u all.

    • @kaakib8841
      @kaakib8841 3 роки тому

      Sir
      Floor to floor height... Inner to inner distance lenge na?

    • @kaakib8841
      @kaakib8841 3 роки тому

      Aapne plinth k top se slab ka top liya huwa hai

    • @azharnalbandh4029
      @azharnalbandh4029 3 роки тому

      @@kaakib8841 in to in floor to ceiling ho jayga, think about it

    • @anuragkhati4547
      @anuragkhati4547 2 роки тому

      Sir if bars are of different dia then how do we adjust the cutting length

    • @vitthalpatil1974
      @vitthalpatil1974 2 роки тому

      column size is 350mm*2750mm. 34 bars of 20mm dia are vertical bars . cover is 75mm. Stirups bars are of 8mm dia. Master ring is easy to calculate but i m having problems with link bars. So plz tell me how to calculate Cutting length of link bars in column. There are 3 rings in which 4 bars are set i.e 12 vertical bars are in 3 rings and 3 vertical bars are in one ring. Total 15 and Master ring includes 2 vertical bars . Total 17 and similarly 17 bars on others sides.

  • @NileshKumar-rv3bk
    @NileshKumar-rv3bk Рік тому +3

    51d = 51*16= 816 mm hoga . Par apne 306 liya h. In case Mera development length Ld middle portion se jayad ho jayega to kya karenge . Jaise Floor height 3 m h Mera dia of bar 20 mm h aur Ld = 51*20 = 1020 mm then Mera overlapping support side me chala jayega . Is case me kya karenge

  • @soumenghosh6743
    @soumenghosh6743 3 роки тому +3

    306 nehi 816 hoga

    • @EverythingCivil
      @EverythingCivil  3 роки тому

      At what time stamp?

    • @soumenghosh6743
      @soumenghosh6743 3 роки тому

      51*16=816 mm

    • @soumenghosh6743
      @soumenghosh6743 3 роки тому

      @@EverythingCivil 51*16=816 mm

    • @EverythingCivil
      @EverythingCivil  3 роки тому

      Yes error hogaya waha..but imp ye hai ke waha lap length lena hai...jo har kisi project me alag hota hai thoda thoda.

  • @vivekborse2790
    @vivekborse2790 3 роки тому +3

    51 x 16=816 mm

  • @raviraj96k74
    @raviraj96k74 2 роки тому +2

    51 d for 16mm bar =816

  • @aryaman4068
    @aryaman4068 Рік тому +1

    Bend deduction????
    One 90⁰ bend
    -2d?????

  • @jitendraalshi6075
    @jitendraalshi6075 9 місяців тому

    U made calculation wrong I.e. 51 x d(16)= 816mm but you consider it as 316mm .

  • @sarojchhotray8287
    @sarojchhotray8287 Рік тому +1

    51*16=306???

  • @pranavnaxane2252
    @pranavnaxane2252 Рік тому

    Wrong:-Check development length. 51*16=816mm.

  • @ankursinghsingh729
    @ankursinghsingh729 2 місяці тому

    Bhai aapne Ldt ka calculation galat kiya hai 51x16= 816mm aayega na ki 306

  • @sarthakmohapatra3738
    @sarthakmohapatra3738 4 роки тому +2

    Excellent video sir. All of ur videos r different from the rest of the UA-cam videos done by other people. Although there r tons of videos on finding out CL of column, but ur videos r always on the edge.
    Thnx

    • @EverythingCivil
      @EverythingCivil  4 роки тому +1

      Thank u so much Sarthak.
      This really means a lot.
      Keep supporting ❤️

  • @AshishKumar-mv8dm
    @AshishKumar-mv8dm 6 місяців тому

    51d= 51x16= 816mm how did you consider 306mm

  • @hz8200
    @hz8200 4 роки тому +1

    Thanks sir..ap sab Kuch practically samjhate hoo. Jo koi aur UA-camrs Nahi batatae

  • @dulhapur
    @dulhapur 3 роки тому +1

    For finding A zone and B zone in coloumn only two floor beams are considered,is not lintel tie beam required to be considered?

  • @ashwins1485
    @ashwins1485 2 роки тому

    51*16=816

  • @ROXY-zm6dd
    @ROXY-zm6dd Рік тому

    L bar ka length consider karna bhool gaye aap😊

  • @themimic-chetanubale1603
    @themimic-chetanubale1603 Рік тому

    Slab thickness kyo nahi pakada

  • @deoraobankar8259
    @deoraobankar8259 4 місяці тому

    Thanks i understand.

  • @kapilrana5756
    @kapilrana5756 11 місяців тому

    o.306 kaise agya jab stageered apka 806 hai to

  • @dilipdebnath4929
    @dilipdebnath4929 Рік тому

    51d=51x16=816m=0.816 mt .I think this is the correct calculation .you have shown this as 306 mm=0.306 mt. This totaly wrong.

  • @hanumanthubellam6691
    @hanumanthubellam6691 9 місяців тому

    How to take lap points

  • @pradeepkumaryadav3859
    @pradeepkumaryadav3859 3 роки тому +1

    Great sir Crystal clear explanation sir.
    Learning can be there in 4 to 5 minutes video as others do , but urs is excellent sir , complete details u hv given sir
    Thanks u so much .
    Abhi aap shuttering pe video laye sir making se lekr checking takkk

  • @snehasispatra8443
    @snehasispatra8443 3 місяці тому

    51x16 = 306 mm ???😂

  • @cricketreview9037
    @cricketreview9037 Рік тому

    Only 2 zone

  • @Rajana89
    @Rajana89 Рік тому

    51d is not 306

  • @shabeebali9742
    @shabeebali9742 3 роки тому +1

    Ld is incorrect , 51d , 51*16 =816mm= 81 cm

  • @vishalmhaske604
    @vishalmhaske604 Рік тому

    Kya bakwas padate ho bhai 😐

  • @deepakraja42
    @deepakraja42 Рік тому

    Sir I had took 6 ft below ground for footing and 4,5,6 ft steel above the ground . Now I overlapped the steel on ground floor and also given joggle.
    Sir mujhe g+4 banana hain kyonki maine ground floor pe lapping diya hain toh isse farak toh nai padega na. My all pillar size is 9*18 . Baaki main aur strong karne ke liye lapping ko welding Kara du kya. Pls answer sir

  • @indian2881
    @indian2881 9 місяців тому

    Bakwass apne ko hi smja ra

  • @balkrushnapatil2242
    @balkrushnapatil2242 Рік тому

    51×16=816 hota hai 306 nahi

  • @AjitSk21
    @AjitSk21 Рік тому

    We have taken Tue beam at bout 5ft from footing and pn above of tie beam we have taken plinth bem of 5ft ...
    But due to improper planing at start we are getting lap joint between Tie bem and plinth beam .. is that allowed??

  • @onlymemes7842
    @onlymemes7842 2 роки тому

    lap legth galat li he

  • @ron4928
    @ron4928 3 роки тому

    So there are 5 staggered and 5 non staggered bar in column

  • @homeplan3532
    @homeplan3532 Рік тому

    Sir mere column ke sariye plinth beem se 3.6 & 4feet height hai to mujhe ab lapping ke liye ab sariye ke cutting height rakhni chahiye

  • @RajUp-l1c
    @RajUp-l1c 7 місяців тому

    Thank you thank you you just cleared my doubt since 4 years

  • @naushadalam7201
    @naushadalam7201 2 роки тому

    Explain is not properly,

  • @faizmalik3187
    @faizmalik3187 2 роки тому

    Gokani consultant I m also working on gokani r. C. C. Drawing

  • @HammadSherwani-q5n
    @HammadSherwani-q5n Рік тому

    Perfectly explained❤

  • @TOP10-z5k8s
    @TOP10-z5k8s Рік тому

    Bro slab to slab distance ya beam k depth minus Krna hai ??

  • @Kumar-kf3cg
    @Kumar-kf3cg 3 роки тому

    Pleased provide bridge pile bbs

  • @shabeebali9742
    @shabeebali9742 3 роки тому

    Can you send the PDF file

  • @pranayalte4193
    @pranayalte4193 3 роки тому

    51d= 16×51=816 then how you got 306?

    • @EverythingCivil
      @EverythingCivil  3 роки тому +2

      It was calculation error. Hope u understand. 😁

  • @avdheshbhatt2290
    @avdheshbhatt2290 Рік тому

    very very helpfull video sir

  • @souravbhandari7348
    @souravbhandari7348 3 роки тому

    please make a video on multiple beams bbs

  • @mdfaiyazmiyan7959
    @mdfaiyazmiyan7959 2 роки тому

    Overlapping 51×d, 51×16=816 hota hai.
    App ne bola 306 kaise hota hai

    • @EverythingCivil
      @EverythingCivil  2 роки тому

      I was calculating live. It was a calculation error. Please understand the concept.

  • @modassariqbal306
    @modassariqbal306 4 роки тому

    Sir agr hamra Design mix me OPC 53 cement use kiya gya but kya me PPC cement used kr sakta hu column concrete k liye OPC 53 ki jagej p....kya strength p column k kuch farak parta hai kya

    • @EverythingCivil
      @EverythingCivil  4 роки тому +1

      Nahi bilkul nahi. PPC cement me pozzolona material mix hota hai to uski strength OPC 53 se kam ayegi aur agar cement ki strength kam ayi to concrete ki bhi kam ayegi..agar ap chaho to design mix me flyash add kar sakte ho usse cement ka consumption kam ho jayega.
      PPC use karne se pehle uski strength check karo kitni aarahi hai agar opc53 jitni hai to it's ok..lekin yaad rakhna initial strength 70% bohot late ati hai PPC ki.

  • @khushalharne5232
    @khushalharne5232 4 роки тому

    First view Bhai 👌👌
    Nice Information

    • @EverythingCivil
      @EverythingCivil  4 роки тому +2

      Thanks brother..keep supporting ❤️
      U people are everything for me.

  • @rayansawant8288
    @rayansawant8288 4 роки тому

    Very usefull video for Civil Engineers!!!!

  • @nadeemsaiyed2186
    @nadeemsaiyed2186 2 роки тому

    Is 7 mt bar cutting length is allowable. As per rule it should be 4 mt only?

  • @amitkumarsah9435
    @amitkumarsah9435 3 роки тому

    isnt that bent up portion is called staggered portion or staggered and lapped portion mean the same?

    • @EverythingCivil
      @EverythingCivil  3 роки тому

      Yes but staggered lapping means not all the lap should come at same levels.

  • @armyofficermanishsharma5039
    @armyofficermanishsharma5039 4 роки тому

    Happy Engineers day brother

  • @yasirzhari2523
    @yasirzhari2523 4 роки тому

    Best channel for civil engineers

  • @nileshsonawane324
    @nileshsonawane324 3 роки тому

    Shayad aap ki hi talash thi...bhai pls ek layout par details main ek video banao pls...

  • @anuragkhati4547
    @anuragkhati4547 4 роки тому

    Sir 12mt steel ko provide kr saktey hai ek hi length m pura ??

    • @EverythingCivil
      @EverythingCivil  4 роки тому

      Haan agar apki puri cutting length lap wagera mila ke 12m ke andar arahi hai to kar sakte ho aap.

    • @anuragkhati4547
      @anuragkhati4547 4 роки тому

      Thnx

  • @modassariqbal306
    @modassariqbal306 4 роки тому

    Thnku so much sir!!

  • @pavush326
    @pavush326 3 роки тому +1

    One of the top quality ...video with superb detailing ...🙏

  • @anuragkhati4547
    @anuragkhati4547 4 роки тому

    Sir BBS site par hi calculate krna pdta hai kya ??

    • @EverythingCivil
      @EverythingCivil  4 роки тому

      Haa VFC drawing ane ke bad banta hai kaam shuru karne se pehle. Fitter ko cutting length dena padta hai cutting bending ke liye.

    • @anuragkhati4547
      @anuragkhati4547 4 роки тому

      Bada project ho to usme kaise site p ho paeyga itni calculation ??

    • @EverythingCivil
      @EverythingCivil  4 роки тому

      Badi site hogi to unka ek alag dept hoga billing ya QS with special staff who are experienced in this. Usually contractor is responsible for making the BBbs and client certifies it.

    • @anuragkhati4547
      @anuragkhati4547 4 роки тому

      Ohk thanx a lot sir

  • @dulhapur
    @dulhapur 3 роки тому

    Clear Height between plinth beam top and roof beam bottom-11 feets
    Zone-A-11/4=33 inches
    Zone-B-11*12-66=132 -66=66 inches
    There are 6 bars 16mm@4,12mm@2
    At zone B top- 2 no of lappings
    At zone B middle(30 inch below top lapping points)-3 no of lapping
    At Zone B bottom (30 inch below middle lap point)-1 lapping
    Whether the above arrangement is allowble?
    Whether lintel tie beam can be provided any zone?
    What if lintel tie beam falls on zone-A top area?

  • @raviyadav7223
    @raviyadav7223 2 роки тому

    Sir isme jo 51d bola hai uska calculation 306 kaise hai 51×16= 816