How to calculate land surface temperature from Landsat 8 Satellite Data

Поділитися
Вставка
  • Опубліковано 13 січ 2025

КОМЕНТАРІ • 83

  • @soumilimukherjee7120
    @soumilimukherjee7120 3 роки тому +3

    Omg thanks I was dying for like 2 days with this thing!!!!!

  • @pedestrianfun7956
    @pedestrianfun7956 4 роки тому +9

    Thanks for this video, it's super helpful. I have one clarification. For the PV calculation, I think the denominator is NDVImax - NDVImin instead of NDVImax + NDVImin. You used subtraction not addition when you did 1 - (-1) -> 1 + 1 = 2. Otherwise the denominator would be 0.

    • @mam2014
      @mam2014 3 роки тому

      Yes, you are right. However, it was a nice presentation.

    • @w.w.8951
      @w.w.8951 3 роки тому

      @@mam2014 totally agree! Congrats Vikas

  • @ritujshrivastav
    @ritujshrivastav 2 роки тому +1

    You are a Legend...Thank you so much!!!

  • @pasanmadhawawithana3646
    @pasanmadhawawithana3646 3 роки тому +1

    This is really helpful. Thank you for making such a valuable video.

  • @apoorvamalviya1960
    @apoorvamalviya1960 Рік тому +1

    first of all you presented it very well sir. can you please explain the value of a and b in the emissivity formula like why those specific values you took? is there any specific method to determine the values of a and b based on different area and scene. in addition can you also explain the final LST formula specially the BT/1 and BT/14380 part! like again if there is a specific value of denominator based on different scene.

  • @madhumitadas156
    @madhumitadas156 Місяць тому

    Thank you so much sir ❤❤❤

  • @ascorbicbumbas8606
    @ascorbicbumbas8606 6 місяців тому

    Thank you for sharing this your insightful tutorial, but please which algorithm is it ?

  • @monikajain7803
    @monikajain7803 3 роки тому +2

    sir, while calculating pv where the formula is ((NDVI-NDVImin)/(NDVImax+NDVImin)).....where you have used the values as (NDVI image+1)/(1+1)....in the second part y it is (1+1)? as we have the negative value as minimum NDVI as - - is understable that it will become + but when it -+ so how it became +?

  • @dulariparmar3091
    @dulariparmar3091 3 роки тому

    thank you for such a detailed informative video!!

  • @anisanisvideo
    @anisanisvideo 3 роки тому +1

    My NDVImin nad NDVI max are not 1 and -1, it is somewhere (-0.3 and +0.56) in that case, for PV calculation.. should i enter these numbers as max min or 1 and -1 only?

  • @aermodmodel
    @aermodmodel 3 роки тому

    This is really helpful. Can you caculator TDVI (temperature
    vegetation dryness index) ?

  • @GeographyMadeEasy
    @GeographyMadeEasy Рік тому

    Sir the value of W that is 10.8
    Is it given in meta data ?

  • @lalitb
    @lalitb 3 роки тому

    Sir, do we need to make separate maps to see LST change in time interval?

  • @prajwalparmar4486
    @prajwalparmar4486 2 роки тому

    Should we clip the study area in the beginning?

    • @vikasghadamode
      @vikasghadamode  2 роки тому

      If you wish to clip in beginning you can clip no problem

  • @MohitSingh-pb6bi
    @MohitSingh-pb6bi 3 роки тому +1

    Which algorithm it is ? mono window algorithm ? single channel algorithm ? or split window algorithm ?

  • @shilpayanghatak8170
    @shilpayanghatak8170 2 роки тому

    Wrong prosess, but right answer.

  • @abhilashagogoi4776
    @abhilashagogoi4776 2 роки тому

    Is this calculation required for level 2 products?

  • @bishnuchaudhary9807
    @bishnuchaudhary9807 3 роки тому

    while calculating PV, as NDVI min value is in negative this becomes +1 in numerator but not -1 is denominator. reason!!

  • @a.n.1167
    @a.n.1167 3 дні тому

    22.36 time per jo aap ne Value di hai 14380, voh Glt hai .......1.4380 hoti hai ye Bhai Sahab 🙏

  • @shubhamsni5428
    @shubhamsni5428 2 місяці тому

    from where to download ARCGIS map software .. can u please provide me link to download the software

  • @vijayendrapratap1234
    @vijayendrapratap1234 2 роки тому

    Is it necessary to do radiometric or atmospheric correction before the LST calculation? Please tell me sir

  • @azharudinwaza5831
    @azharudinwaza5831 2 роки тому +1

    Bahi 64 degree temp. is impossible.Till now the highest temp. record in the world is only 56.7 degree..
    I think your estimation is wrong. If not then plz do clear me.

  • @ayanghosh2481
    @ayanghosh2481 3 роки тому

    Very good.....

  • @36july24
    @36july24 2 роки тому +2

    You made mistake in basic math. that's why LST became 64 degree celcius. Human brain would come out through nose in 64 degree..

  • @vandanatomar1688
    @vandanatomar1688 4 роки тому +1

    Why can't we use both the bands i.e 10&11 for calculating LST from Landsat 8 data ??

    • @vikasghadamode
      @vikasghadamode  4 роки тому +1

      You can use band 11 also same process you can try on band 11 also

    • @vandanatomar1688
      @vandanatomar1688 4 роки тому +2

      @@vikasghadamode my concern was that is it ok to use both the bands or only single band will give us the desired results?
      Anyways your video is helpful though 👍

    • @vikasghadamode
      @vikasghadamode  4 роки тому +1

      @@vandanatomar1688 if you try from both band then it will better result

    • @porchelvananbarasu1697
      @porchelvananbarasu1697 3 роки тому +1

      @@vandanatomar1688 have u tried it form both bands? how was the result?

  • @sakshisudhakar1601
    @sakshisudhakar1601 7 місяців тому

    Hlo sir how to conversion value of reflection

  • @nayanchoudhary9629
    @nayanchoudhary9629 4 роки тому +1

    Thanq sir

  • @jahangirabbas8837
    @jahangirabbas8837 Рік тому

    THANK YOU SO MUCH

  • @abhishekr3505
    @abhishekr3505 3 роки тому

    Hi sir iam getting ndvi from -0.26 to 0.56 its ok

  • @balrajjamwal8876
    @balrajjamwal8876 2 роки тому

    What if the al is in negative

  • @dheerajsonkarswce5344
    @dheerajsonkarswce5344 2 роки тому

    sir landsat-9 (W) value????

  • @shatabdisinha6779
    @shatabdisinha6779 10 місяців тому

    My NDVI is not showing -1 to 1 range, it is showing some other integers.. is it okay to carry forward?

    • @vikasghadamode
      @vikasghadamode  10 місяців тому

      I think you didn't use float in formula

  • @intuitivepeace6470
    @intuitivepeace6470 2 роки тому

    How can I get arc gis software?

  • @shashidharan6492
    @shashidharan6492 3 роки тому

    bt in india will der be 64 degree temperature? mine is also showing like that so.. mine its showing 67 degrre high nd 37 degree low for bangalore urban? is it possible?

  • @mdgeomedia4647
    @mdgeomedia4647 3 роки тому

    sir, I have a problem when I am trying it in Landsat 5 image, the lower and upper temp.is calculated (-67 deg C) and 142 deg c. after clipping the AOI the temp. is measured 113.27 and 118.437 deg c approximately. Will the constant value change? If so, please tell me the constant values used in the case of Emissivity and LST, at the time of calculation.

    • @annrotich7508
      @annrotich7508 2 роки тому +1

      When using LANDSAT 4/5/7 use the single channel algorithm whilst LANDSAT 8/9 use the split method as there are two thermal bands(10 and 11).Different methods are used to calculate the LST.

    • @zainulabideen4728
      @zainulabideen4728 2 роки тому

      You have to use low reflectance value to calculate lst of landsat 5 band (low 0. High 150 aproximatly ). Then your lst is fine

    • @PoojaSharma-hs1dz
      @PoojaSharma-hs1dz Місяць тому

      @@annrotich7508 I am trying to calculate LST. But the algorithms are giving very high values of temperature while using Landsat 8 Level 2 data. Whereas L1 is giving correct results. So, which data (L1 or L2) should I use ?
      Which data is best to use ?

  • @codingchampians7268
    @codingchampians7268 2 роки тому +1

    Vikas Sir, My Study area temprature is 5.26 to 53.382
    So is it Right? Plz reply me Soon

  • @pradyutbera344
    @pradyutbera344 2 роки тому

    Sir, if you kindly tell me the conversion process of the Radiance Multiplicative value of band 10 (3.3420E - 04 = 0.0003342), I'll be grateful.
    Thank you in advance.

  • @gunneramsey2969
    @gunneramsey2969 2 роки тому

    could you please show me the reference for these formulas??

  • @Dineshkumar-u7v3e
    @Dineshkumar-u7v3e Рік тому

    thank you

  • @kirtichowdhury6060
    @kirtichowdhury6060 3 роки тому

    Sir video is awesome. Sir I would like to know how to do mapping of water turbidity?

  • @rahulnarayanthapa
    @rahulnarayanthapa 4 роки тому +2

    It is showing temperature more than 60+ that is impossible in real world, how can we correct it

    • @athlete265
      @athlete265 3 роки тому

      yeah beacause i think ndvi is caLCULATED WRONGS

    • @shashidharan6492
      @shashidharan6492 3 роки тому

      @@athlete265 even mine shoiwing 69 degree fr bangalore location.. what wrong we did in NDVi can u please explain me...

    • @athlete265
      @athlete265 3 роки тому +1

      @@shashidharan6492 ndvi must be calcaulated by refalnatce value not by radiance values

    • @athlete265
      @athlete265 3 роки тому +1

      Or check formula of everysteps

    • @shashidharan6492
      @shashidharan6492 3 роки тому

      @@athlete265 ya did it again again the temperature is raising and also it's showing negative temperature

  • @Safira6631
    @Safira6631 Рік тому

    Helo, can I get a journal?

  • @roshninetravalkar3866
    @roshninetravalkar3866 2 роки тому

    once I input the formula it's showing error 000539.

    • @vikasghadamode
      @vikasghadamode  2 роки тому

      This error could occur if the output filename is too long or if the "Spatial Analyst" extension is not enabled.

  • @shabiin
    @shabiin 3 місяці тому

    THE IS NEGATIVE SIGN IN BOTH SIDE OF THE FORMULA

  • @kiu258kiu
    @kiu258kiu 3 роки тому

    Why I got ERROR 000539 while calculating LST?

    • @shashidharan6492
      @shashidharan6492 3 роки тому +1

      Do it again. N don't change the output folder let it be the default one... Restart app n try...