Your videos are the best! I watched quite a few videos so I can say your contents are to the point and very descriptive. Thanks for uploading such an educational videos.
Sorry for the delayed response. There's no way to pull that string back in, but you could set a number in each job that would have to match. In other words, you could create an integer in your job that would return a specific ID of the job that's running. Verify based on that.
Hi Vlad -- love your training videos, Have you ever worked with Cognex Native Code? I've done it with Telnet and the Cognex SDK but for some reason I'm having trouble using it through the CompactLogix PLC. I've followed Cognex instruction sheet to the letter and it just doesn't work. Thought you might ve had experience with it?
Hi, thanks for that nice video. I'd like to know how much time it takes for the camera to change that Job? 30secs? Could it take more time if the job is bigger?
That's a good question. I'm not sure how long it takes, but I'm sure that you can figure it out with basic timers on the PLC. I would guess that it would take more time for a larger job to load, but once again, I don't know. I would recommend programming a routine that would check that the camera is back up and running once the job change is complete.
I haven't looked at the CLICK recently, but I believe that it wouldn't import the data as easily as the AB PLCs. I would probably just send digital Inputs/Outputs to the CLICK and use them for rejects. I don't think I'll be making a video on that anytime soon. Sorry.
Hi, I gave a look to your website, I would like to buy a subscription because I am interested in your vfd tutorials as well as poit IO and hardware. My question would be, do you also have more vision tutorials on your website than this one on UA-cam?
I've got a Cognex class posted on Udemy that's not on the main website yet. I'm working on migrating it. It's not overly advanced, I'm primarily focused on showing how to get the camera configured, how to read values from it and how to do simple image processing.
@@SolisPLC thanks for your fast response, I already found your course at udemy and I will suscribe. I have been working on some projects as a PLC programmer in Mexico since 2 years ago aprox, but there are some gaps that I would like to cover on my learning of PLC since I dont have too much experience with VFDs and vision.
Hello Solis, I was wondering if you can create the same video but using DATAMAN software. I'm working with a Dataman 260 and a CompacLogix PLC. I need to get the result string and figure out how to send the barcode number to validate it to the reader. Thanks
How about get a status Ok / Not oK result from the present and absent Cognex 5100 with Control Logix ? Currently i am using digital signal for Ok and Not Ok but it seems the signal a little bit delayed. I need it to connect by the ethernet. Could you please share the config of the camera ?
After setting offline and using message instruction, what do you do to put it back in online mode? I am new to Cognex and am working on an application to change jobs using Insight 2000 series camera within RS logix 5000. Any help is appreciated
I'm not sure how he does it but I run this program as a step sequence where it latches it offline at the beginning and unlatches it at the end. It works for me.
Hey Mitchell, can you send me more info on the error (v.romanov@solisplc.com)? The only thing that comes to mind is that either your arrays aren't the same or the instruction isn't pointing to the right element.
Your videos are the best! I watched quite a few videos so I can say your contents are to the point and very descriptive. Thanks for uploading such an educational videos.
Hello Vlad
Thanks for sharing. It is work to solve my issue on my machine.
Thanks a lot sir!
Thank you. I am just getting into in-sight, very helpful.
Thank you sir, I appreciate the feedback!
thanks for the video, is there any possiblity to see how to set the Camera to get that information?
te sigo desde argentina muy buenos videos felicitaciones
Awesome video!!! Could we use it to set jobs to Dataman also? Thanks!!!
Hi, it's amazing. It really helped me on my project. Is it possible to see which Cognex Job is running on the PLC?
Sorry for the delayed response. There's no way to pull that string back in, but you could set a number in each job that would have to match. In other words, you could create an integer in your job that would return a specific ID of the job that's running. Verify based on that.
Hi Vlad -- love your training videos, Have you ever worked with Cognex Native Code? I've done it with Telnet and the Cognex SDK but for some reason I'm having trouble using it through the CompactLogix PLC. I've followed Cognex instruction sheet to the letter and it just doesn't work. Thought you might ve had experience with it?
Hi, thanks for that nice video. I'd like to know how much time it takes for the camera to change that Job? 30secs? Could it take more time if the job is bigger?
That's a good question. I'm not sure how long it takes, but I'm sure that you can figure it out with basic timers on the PLC. I would guess that it would take more time for a larger job to load, but once again, I don't know. I would recommend programming a routine that would check that the camera is back up and running once the job change is complete.
Great stuff. Would it be possible that you do a job with the Cognex and a Click PLC?
I haven't looked at the CLICK recently, but I believe that it wouldn't import the data as easily as the AB PLCs. I would probably just send digital Inputs/Outputs to the CLICK and use them for rejects. I don't think I'll be making a video on that anytime soon. Sorry.
Hi, quick question. How I get those tags about index job and all that stuff...
Hi! Can you do the same video with plc Siemen or mitshu? Thanks so much because Rockwwell PLC is not popular in my country!
Hi, I gave a look to your website, I would like to buy a subscription because I am interested in your vfd tutorials as well as poit IO and hardware. My question would be, do you also have more vision tutorials on your website than this one on UA-cam?
I've got a Cognex class posted on Udemy that's not on the main website yet. I'm working on migrating it. It's not overly advanced, I'm primarily focused on showing how to get the camera configured, how to read values from it and how to do simple image processing.
@@SolisPLC thanks for your fast response, I already found your course at udemy and I will suscribe. I have been working on some projects as a PLC programmer in Mexico since 2 years ago aprox, but there are some gaps that I would like to cover on my learning of PLC since I dont have too much experience with VFDs and vision.
Nice video. Do you have anything for setting up ethernet i/o in cognex spreadsheet. i am new to this
Hello Solis,
I was wondering if you can create the same video but using DATAMAN software. I'm working with a Dataman 260 and a CompacLogix PLC. I need to get the result string and figure out how to send the barcode number to validate it to the reader.
Thanks
Hi Daniel, I haven't worked with the Dataman for a while. I'll add it to my list of content, but I wouldn't promise it to be released soon.
Does it work for Insight 2000 as well?
did you install the EDS file before you programmed it or you added the module as a generic ethernet module?
How about get a status Ok / Not oK result from the present and absent Cognex 5100 with Control Logix ? Currently i am using digital signal for Ok and Not Ok but it seems the signal a little bit delayed. I need it to connect by the ethernet. Could you please share the config of the camera ?
hi, very good video. Could you send me the manual? I´d like to do this kind of change of job in a machine in the company that i work.
Sure, send me an email to v.romanov@solisplc.com
Could you make more examples about it please?
Hi!
How can i job change program cognex insight 2000 with omron plc vic ethernet IP?
After setting offline and using message instruction, what do you do to put it back in online mode? I am new to Cognex and am working on an application to change jobs using Insight 2000 series camera within RS logix 5000. Any help is appreciated
I'm not sure how he does it but I run this program as a step sequence where it latches it offline at the beginning and unlatches it at the end. It works for me.
Vlad,
I keep getting this error on the rung where we move JobName[JobIndex].LEN ..... Error: Rung 17, MOV: MOV(JobName[JobIndex].LEN,JobData[0])
Hey Mitchell, can you send me more info on the error (v.romanov@solisplc.com)? The only thing that comes to mind is that either your arrays aren't the same or the instruction isn't pointing to the right element.
Can I address a few questions I have that you might be able to answer?
Sure, please email me at v.romanov@solisplc.com
I'm stuck using keyence plc