DESIGN OF SLAB TYPE COMBINED FOOTING/DRSS/17CV72/CLASS 23

Поділитися
Вставка
  • Опубліковано 28 жов 2024

КОМЕНТАРІ • 28

  • @shivakumarmathapati4080
    @shivakumarmathapati4080 Рік тому

    Sir is that load you are applying on THE column can it resists G+1 structure load we can go ahead with sir??? please clarify me sir the way of explanation is mind blowing 😊😊🙏🙏♥️sir VERY clear n distinct explanation..

  • @dipjyotibaglari
    @dipjyotibaglari 2 роки тому

    Nice explanation... Which book you are using Sir?

  • @Priya_1_1
    @Priya_1_1 3 роки тому +1

    Amazing teaching sir ❤️❤️👍👍

  • @yashrawal9028
    @yashrawal9028 2 роки тому

    Sir is there any lecture including full design of the raft foundation , I've searched all over the youtube but couldn't find it anywhere sir please upload a video on the design of raft foundation

  • @Rasool1214
    @Rasool1214 2 роки тому

    Sir
    In reinforcement along longitudinal direction
    Ast is 345.27
    Wat shld be done further

  • @sanhitasaha6556
    @sanhitasaha6556 3 роки тому +1

    Sir what will happen if 2nd column is circular. In one qstn paper it came like that?

    • @mitmysorecivil9178
      @mitmysorecivil9178  3 роки тому +1

      if column is is circular also, follow the same proceedure. because footing will be rectangular.

  • @civilconst
    @civilconst 3 роки тому

    Why didn't you checked for one-way shear sir ?

    • @punithn3782
      @punithn3782 3 роки тому

      You can do both one way shear and two way shear check.

    • @punithn3782
      @punithn3782 3 роки тому

      If one way check fails means you need to increase depth and redesign.

    • @punithn3782
      @punithn3782 3 роки тому

      Better to do both checks.

  • @aiman2562
    @aiman2562 3 роки тому +1

    Sir please start steel designing ie truss n gantry girder we have internal

    • @punithn3782
      @punithn3782 3 роки тому +1

      2 more class required to complete slab type combined footing. After that I will start with steel structures.

    • @aiman2562
      @aiman2562 3 роки тому +2

      Please start the steel structures design sir

    • @punithn3782
      @punithn3782 3 роки тому

      Sure I will do detailing part

  • @nehaankale6662
    @nehaankale6662 3 роки тому

    Sir in two way shear check for second coloumn the nominal shear stress is more than permissible shear stress.... What to do in this case

    • @mitmysorecivil9178
      @mitmysorecivil9178  3 роки тому

      actually its need to be redesigned by increasing the depth.

    • @nehaankale6662
      @nehaankale6662 3 роки тому

      @@mitmysorecivil9178 thank you sir🙏🏻

  • @aiman2562
    @aiman2562 3 роки тому

    Everyday we check for your new videos but you aren't uploading

    • @punithn3782
      @punithn3782 3 роки тому

      Today I will be uploading pa

  • @parvathymohanan9456
    @parvathymohanan9456 3 роки тому

    Sir calculation of area of critical section how you got 400 by 2

    • @punithn3782
      @punithn3782 3 роки тому

      Just go with the video again. I have explained. Still have doubts means you can contact me.

    • @parvathymohanan9456
      @parvathymohanan9456 3 роки тому

      @@punithn3782 yes i understood sir

    • @parvathymohanan9456
      @parvathymohanan9456 3 роки тому

      @@punithn3782 sir In calculation of reinforcement along longitudinal direction. For span BC portion how u got the BC max bending moment. Because If you are taking from Bending moment means both CD and BC will be same na