What to do if your Salt cell is not displaying any lights / How to repair it

Поділитися
Вставка
  • Опубліковано 7 жов 2024

КОМЕНТАРІ • 93

  • @Sunshinedolphn222
    @Sunshinedolphn222 5 місяців тому +2

    Awesome video! You saved me $600 plus dollars. I am a 62 yr old woman whi has a disable husband and can no longer help out with household repairs. I went to local auto part store; purchased a 30 amp fuse barrel and replace it with a 10 amp; opened my box, no green light; shut down all power and followed your video guidance …and WALA!!! Green light came on and my salt cell lite up. Thank you so much for making your video so user friendly! Sincerely, BJ Reece, USNavy Chief (Retired)

  • @lorettawalker8077
    @lorettawalker8077 8 місяців тому

    You saved me $1000.00 + I kept telling the pool guy I didn't think the salt cell was bad because I would have seen flashing lights indicating the unit wasn't operating properly. This time NO lights. After quite a bit of time troubleshooting getting no power, I came across your post. Replaced the old style fuse with your fix and all is working!!! Thank You, I can't wait to tell the pool guy I was right!

  • @johntimpanaro7640
    @johntimpanaro7640 3 роки тому +3

    Thank you so much! This video saved me $200 and a lot of headaches. I have the old model with the terrible design. The barrel fuse blew and part of it was stuck in the holder which cracked the holder. I got the new holder at an auto store and cut the wires just like the video. Works perfectly now. An electrician wanted $200 and the pool store said they don’t work on these.

  • @THESEGMENTPR
    @THESEGMENTPR 3 роки тому +3

    I did exactly what you said about getting the barrel fuse holder replaced and that did the trick!!! $3.99 cents and about 20min of my time vs a new box at $499. Thank you so much!!!!! Keep up with the amazing content!

  • @AllanRennie-ph6gg
    @AllanRennie-ph6gg 4 місяці тому

    Excellent video, I completed the fuse bypass because my older control unit fuse was oxidized out at the bottom. Works great now, you are awesome, thank you!

  • @kevinkesterson9891
    @kevinkesterson9891 2 роки тому +1

    So I replaced the entire fuse holder and fuse and that didn't work. Watched your video and the bypass you did towards 4 minutes had already been done. In essence, I replaced the old spot that wasn't even wired. There was already what you had done. Opened the fuse in the middle of wired and there was the blown fuse. Replaced the fuse and works like a charm. Way to go on a great video. Helped a lot.

  • @cjttaylor
    @cjttaylor 2 роки тому +1

    Thank you so much! I used the 30 amp barrel fuse holder with 10 amp fuse. It worked! Your video was so easy to follow. Thank you !!!

  • @1teamsynergy41
    @1teamsynergy41 3 роки тому +1

    Great frustration to Great Enthusiasm - thank you very much. It was recommended I buy another Pentair Intellichlor system. I refused to pay 8x what i paid for my 3 year old system. Then, somehow this video appears. I followed this gentleman's directions to the "T" doing this by myself, and my Pentair Intellichlor system is powered up operating perfectly! Thank you, thank you, thank you!

    • @craigwooster6646
      @craigwooster6646  3 роки тому +1

      Great to hear!

    • @susanmolina5007
      @susanmolina5007 3 роки тому +2

      Excellent video. Thank you so much. It was easy and very clear instructions

  • @NoahRenne-i2j
    @NoahRenne-i2j Рік тому

    Perfect video, I just moved into a house with a pool two weeks ago, Salt cell just shut off Sunday night...sure enough, it was the older barrel fuse...I would have never found it. Appreciate the expertise!

  • @chadrodrigue7469
    @chadrodrigue7469 3 роки тому +1

    Just like many others on here. I have to older system as well. Thought i was going to have to dish out quite a bit of cash because last year i went from an IC40 to an IC60 as i have a 48k Gallon pool and the IC40 died in 2 years. So you can imagine my worries as i see no green lights on the IC60. Changed out the barrel fuse connections just like the video and "MAGIC"!!! THANK YOU Craig!!

  • @SandraSwofford-fq9kq
    @SandraSwofford-fq9kq Рік тому

    Thank you so much for posting this video!!! We simply needed a barrel fuse holder for our older (2012) power box, but would not have known so without this content. Simple fix that worked like a charm. Our salt generator and pool are back up and running! :)

  • @thorkvande5192
    @thorkvande5192 3 роки тому +2

    Great video and very helpful! I followed your directions exactly and was able to bring the salt cell back online! Saved a lot of money!

  • @edkoller401
    @edkoller401 Рік тому

    Thank you so much for the fuse bypass trick. I had the old, gummed up, bottom mounted holder and I'll never have to mess with it again!

  • @allenskinner3067
    @allenskinner3067 Рік тому

    Thanks for the video and tips on checking the fuse. FYI old style fuse is a buss agc 10a 250v fuse. Found at Auto Zone with no problems.

  • @leephilmon6337
    @leephilmon6337 Рік тому

    Thank you for sharing this video. You saved me over $550.00 I thought I was going to buy a new power box..

  • @Sientz
    @Sientz 2 роки тому

    Thank you for this video! My fuse went bad and I replaced it with the 10 amp inline fuse holder. Cost me about $10.

  • @bkopper9112
    @bkopper9112 Рік тому

    Thank you!!! Replacing the fuse did the trick!!!

  • @AJJ-q9y
    @AJJ-q9y 2 місяці тому

    Awesome video, nice and detailed. Right to the point.

  • @bettymirza2801
    @bettymirza2801 2 роки тому +1

    OMG, This actually worked. Thanks for the help saved $$$$.

  • @MarkB-gi7tu
    @MarkB-gi7tu Рік тому

    Thanks for the Video, my solution was a little different. No lights on Cell, when you unplugged cell and cycled power to the box, green light was on. Once cell was connected it would go off so bad cell I thought, got a new one (the one we have is almost 13 years old) new cell had same issue. I thought "how can fuse be bad if light comes on?" Tested both ends of fuse connection, no power coming out of it so I took the old-style fuse out (that was a Challange, had to take holder out to get fuse out) fuse was good, I put it all back to together and it tested good, salt cell worked! Put old salt cell back on and it worked also. Maybe it was just loose, going to leave it alone since it is working, going to get a new fuse holder if issue returns. Maybe it was just not making good contact? May keep the new cell since our is so old.

  • @brettshaffer777
    @brettshaffer777 Рік тому

    Thanks for the Video and tips! My older power supply is popping fuses...I'm hoping my barrel fuse holder is just bad.

  • @ramjosyula8965
    @ramjosyula8965 2 роки тому +1

    Thank you. Saved me a bunch of head ache and expense!!

  • @neileschenbrenner4303
    @neileschenbrenner4303 3 роки тому +1

    perfect, did the trick! up and running again

  • @LouHernandez-o1j
    @LouHernandez-o1j 8 місяців тому

    Thank you Craig so much. Easy job thanks to you.👍🏻

  • @marvinbuente4609
    @marvinbuente4609 3 роки тому +2

    Glad you showed that video

  • @kthekeeper5117
    @kthekeeper5117 2 роки тому

    That muZic was really helpful.

  • @danielosorio9634
    @danielosorio9634 3 роки тому +1

    Thanks it help me a lot. Gracias Señor!

  • @johnhaaland1834
    @johnhaaland1834 Рік тому

    Thank you for this. I was following your directions and there was simply a loose connection in the fuse area. If it happens again then I will replace with a barrel fuse.

  • @RobRoy007
    @RobRoy007 6 місяців тому

    Outstanding! thank you Sir!

  • @c.m.b.598
    @c.m.b.598 2 місяці тому

    The fuse🙌🏾💯Thank you

  • @jamessoler
    @jamessoler 3 роки тому +1

    Nice job!! Helped a lot.

  • @johnpoelman6862
    @johnpoelman6862 2 роки тому

    Thanks very much! A 50 cent fuse is all it took!

  • @JoeDeLorenzoRIT
    @JoeDeLorenzoRIT 3 роки тому +1

    Great Video Thanks !

  • @HT-fp2wx
    @HT-fp2wx 3 роки тому

    Thank you Craig

  • @rotfan77
    @rotfan77 2 роки тому +3

    Just a quick question, if the fuse pops immediately that means the salt cell is shorting ? would cleaning the salt cell meaning what if there were some calcium between the grids will that cause it does short immediately or is it more likely something in the electronics on the cell itself? Since these things are so expensive I just wonder if there was anything that could possibly be repaired in the cell?

  • @indymustang1969
    @indymustang1969 2 роки тому +1

    Mine suddenly stopped working and no lights at all...which led me to this video. I did open up the power source and the green LED is on. So did the SWCG just spontaneously go bad? I don't get it. The only thing that has happened is that my pool company came out for weekly maintenance and then I saw the lights were out. What would have happened? Is my only remedy to go buy a new $1000 part?

  • @alejandrosantiago4596
    @alejandrosantiago4596 2 роки тому +1

    You rock 🎸 amigo

  • @andrewcozier
    @andrewcozier 3 роки тому +1

    Have you ever seen the transformer going bad? I am getting power to the transformer but no power from transformer to fuse. Thanks for the video.

  • @rcharger007
    @rcharger007 3 роки тому +2

    Hi! Great video. Had a quick question just to confirm. So here you basically bypassed the old fuse holder leaving it in place, and with clipping the ends on the wires putting in to the new barrel holder? And essentially leaving the old holder in place it looks like which would not be used going forward. I believe my fuse is stuck in there as when I pulled out the gray plastic at the bottom that is all that came out, no fuse or the metal holder that looks to be attached to that gray cap.

    • @craigwooster6646
      @craigwooster6646  3 роки тому +3

      That is common. I don't bother attempting to remove the fuse or the fuse holder, not worth my time and I don't want a hole in the bottom of the box. You could replace the original fuse holder, they are readily available, however it is cumbersome to do and the new one will also eventually fail. I just install a new barrel fuse holder and burry it in the power center

  • @agentxyz
    @agentxyz 27 днів тому

    i like you. il like your video.

  • @maryjokohn4703
    @maryjokohn4703 2 роки тому +3

    Quick Question I have a newer style with the 10 amp mini fuse I have replaced it and the little green light inside power supply still not on? Is this a power supply issue then?

    • @jonathanvictory82
      @jonathanvictory82 2 місяці тому

      Did you resolve your issue? I'm having the same issue when I replace the newer 10A fuse. No green light.

  • @donjaffe3650
    @donjaffe3650 2 роки тому +1

    I have a ichlor 30. Checked the fuse with multimeter and it's good. No green lights in transformer and still no power to the cell. Would you think it's the transformer. Transformer has power coming into it. Thanks

  • @carsonmwiley
    @carsonmwiley 2 роки тому

    Same symptoms, no power to control box. Barrel fuse is still good though. No green light on. Bad cell or bad control box? Thx

  • @ericdodge8227
    @ericdodge8227 2 роки тому

    I have the older power center model with the Buss fuse. It's fine. My problem is an intermittent connection. I have a new IC40 that worked fine for a year, but now I only get power to it if i press hard, up, on the connecter, after being sure I've got it fully inserted and secure. I'm assuming the female receptacle is bad? corroded? Would that be hard to replace?
    BTW, interesting that the new IC40 is upside down from the old one. To get the flow in the right direction I had to mount it "upside down".
    Thanks for any help

  • @Marlin365
    @Marlin365 2 роки тому

    Nice video! i have an iChlor-15 cell that Pentair replaced under warranty. But on the new iChlor-15, now I have no lights at all. I have checked 1) 240V coming into the Power Center, 2) Green Light is on. I took the red automotive fuse out and light went off, put it back in and green light is on. I kept my old iChlor-15, which was working but had 1 bad indicator light, so I just swapped that one in, but still no lights on the iChlor cell at all. Any other ideas to try? Thanks!

  • @bmack500
    @bmack500 Рік тому

    Do you have anything on how to tell if the transformer is working properly?

  • @dreamtheater_92
    @dreamtheater_92 4 місяці тому

    My unit is 6 years old and I can't locate a fuse anywhere. I do see the 4 small circuit breakers in the top panel, but none are tripped. Where else can I look?

  • @timwhaley8810
    @timwhaley8810 3 роки тому +1

    How do you change the barrel fuse sir?

  • @awmichaud
    @awmichaud 2 місяці тому

    Assuming the cell is bad If the fuse blows right when you turn the power on after replacing the fuse? Red light comes on after it blows the fuse.

  • @amandagallegos7381
    @amandagallegos7381 3 місяці тому

    I have power but the output side isn’t coming on. What do I do?

  • @MattFoushee
    @MattFoushee Рік тому

    What if the blade fuse continues to blow even if not attached to the power cell? How do you determine if it is the board or the transformer?

  • @kirangrewal6103
    @kirangrewal6103 2 роки тому +1

    My fuse keeps blowing. Any tips? or ideas as to why that's happening? The cell has been cleaned.

  • @okedoke1234
    @okedoke1234 3 роки тому

    Today , our IChlor 30 lights went out. Unit has 1,076 hours on it and is about 2 years old. Fuse is good and green light is on in the power box.

    • @JB-ie3vo
      @JB-ie3vo 3 роки тому +2

      You ever figure this out? Same thing here. First season. Only about 3 months old.

    • @okedoke1234
      @okedoke1234 3 роки тому

      @@JB-ie3vo James here is what I think happened. Our IChlor has to be installed "upside down" due to the configuration of our water lines. This is not a problem for the controls as you can flip them over and apply the new sticker. HOWEVER I noticed there is an opening for the power cord to go in, which normally would be on the bottom. Since ours was flipped it was on top, with a rather large opening around the cord, I think rain got into there and shorted it out.
      Just my theory. On our new unit I taped around that opening to keep out the rain.

    • @JB-ie3vo
      @JB-ie3vo 3 роки тому +1

      @@okedoke1234 Ahhh gotcha. I think we’re going to need a new cell. Fortunately it’s still under warranty.

    • @okedoke1234
      @okedoke1234 3 роки тому

      @@JB-ie3vo Yeah luckily ours was covered. Keep the serial number handy and track the hour meter.

  • @saintsandsin3885
    @saintsandsin3885 2 роки тому

    How do you test the easy touch? I had a fuse pop in the easy touch and when I pushed it back in the salt cell lit up for a few moments and then went out again.

  • @pablopicaso9735
    @pablopicaso9735 3 місяці тому

    My Pentair Ichlor 30 is showing an AC code. It's getting AC power instead of DC. I changed out the power supply and it's doing the same thing. Is my cell bad?

    • @craigwooster6646
      @craigwooster6646  3 місяці тому +1

      Your cell is bad, most times when you get an Ac code it is a bad cell and not a bad power center

  • @MichelleGoldfield
    @MichelleGoldfield Рік тому

    What do I do if I just replaced the salt cell today & replace the fuse just now. Power everything up, it runs for 2-3 minutes and then slowly burns through the fuse?

  • @mrgator1221
    @mrgator1221 Рік тому

    So what makes the cell go bad we did have a big lightning storm, but it didn’t even blow the fuse

  • @mapools777
    @mapools777 Рік тому

    What if the ichlor 30 cell display is not on but flow and cell lights are working?

  • @andrewbako9494
    @andrewbako9494 Рік тому

    I bought a new cell and a new power supply replaced both of them I still don't have any lights nothing's working and I don't have a green light on a brand new power supply

  • @jaimegarcia1613
    @jaimegarcia1613 Рік тому

    I have no lights on cell but fuse is good board have green light
    Cell is 4 years old 🎉
    Any suggestions?

  • @MrTravel4nutin
    @MrTravel4nutin Рік тому

    Naturally, as my luck would have it. I have a new set-up. I replaced the fuse and there's no light. This is the one thing not me tioned in the video or the comments.

  • @Sny190
    @Sny190 2 роки тому

    Its possible I missed this. I switched the fuse and without the salt generator connected, the green light stayed on indefinitely. I connected the salt generator and the light went off within seconds. What's going on here?

  • @jimcox7134
    @jimcox7134 2 роки тому +1

    My green light is on, but the salt cell has no lights at all. Ideas?

    • @craigwooster6646
      @craigwooster6646  2 роки тому

      It is almost certain that the salt cell has failed

    • @bennyb8809
      @bennyb8809 2 роки тому +1

      @@craigwooster6646 I had a bad generator cell (flow switch) as the metal tab broke off so flow showed red. I got a new flow switch and swapped it out and now the salt level indicators have no lights, but everything else is on and green. Any ideas?

  • @catsumrs
    @catsumrs Рік тому

    Is there a reset button?

  • @elcheapofl
    @elcheapofl Рік тому

    Wish my problem was just the fuse; it's close to the 10,000 hrs of cell life so its time to replace.

  • @Paul-yy8vp
    @Paul-yy8vp 3 роки тому

    Why use 30 amp for a 10 amp fuse can I use a 20 amp inline fuse holder

  • @mule5150
    @mule5150 3 роки тому

    If the 10 amp fuse is good and there is no light is the controller shot ??

    • @craigwooster6646
      @craigwooster6646  3 роки тому

      Which fuse do you have? If it is a on the circuit board with the green LED light, then replace the power center. If it is on the bottom of the power center and is a barrel fuse, then replace the fuse holder and then check it. 90% of the time that fuse holder goes bad

    • @swacord
      @swacord 2 роки тому +2

      @@craigwooster6646 how do you replace the power center? Mine is doing the same thing. Led is on but no lights on the cell

  • @somaliskinnypirate
    @somaliskinnypirate 3 місяці тому

    That's it. I'm out. This is the second 40k Pentair salt generator that failed in two years. I'm done. Going to chlorine tabs. Way cheaper than constantly shelling out $1,000. $1,000 item that cannot be repaired because Pentair doesn't subscribe to right to repair.

  • @tl8483
    @tl8483 Місяць тому

    These iChlor units are pure junk. They charge a ridiculous amount for these garbage units only to have them fail in a couple years. There should be a class action lawsuit against Pentair for pushing this junk on the public.

  • @mrgator1221
    @mrgator1221 Рік тому

    you can’t be serious the fuse is good the green light is on, but I have no power to the cell!!! well kiss, a wet puppies, buttt !!!! It’s only two years old !!! that is ridiculous.😡

  • @glenzee9083
    @glenzee9083 2 роки тому

    Plugging in or unplugging your cell with the power on will most likely fry your power supply or your cell. Thats rule 1 you just violated multiple times. Not very good information on this one sorry.

  • @jjoser3104
    @jjoser3104 7 місяців тому

    I just order my salt cell ! One quote form a poll place is IC40= 1550, y the other one 1750 🥹I will work on my cell mañana 🤪Thanks man !