Gauges every HVAC Technician Needs

Поділитися
Вставка
  • Опубліковано 7 сер 2024
  • For the best gauges go visit the website. Yellow Jacket gauges are the standard.
    yellowjacket.com/products/hva...
    This is the set I use.
    yellowjacket.com/product/tita...
    JOIN my channel if you want help in your career as a hvac technician or a hvac contractor..
    / @taddydigest
    ‪@RitchieYELLOWJACKET‬
    #gauges #yellowjacket #hvac #hvactipsfortechnicians

КОМЕНТАРІ • 35

  • @markmcelmeel7850
    @markmcelmeel7850 2 роки тому +4

    What I really like about digital gauges specifically my SMAN 380 manifold is that I am able to see if we have a small leak when doing pressure testing. It’s much easier to discern if we are losing pressure based upon seeing the very small measurements in a digital format. With a analog set, you have to wait a lot longer to tell. But that is about convenience. Superheat and sub cooling are easy enough to calculate but being able to see small pressure drops when the system is off is very helpful

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      Mark thank you for sharing this information this is a really good point yes most digital gauges show you the microns while pulling in a vacuum
      Thank you Mark

  • @tedpedraza6660
    @tedpedraza6660 2 місяці тому +1

    I bought the 46013 Brute 2 I paid $460. I'm proud that I made that investment. Very well built

  • @yorkrojas1452
    @yorkrojas1452 4 місяці тому +1

    Got my First Set of Gauges today, I think it's this same one!!!

  • @chizo5097
    @chizo5097 День тому

    Do you have a video of how to use those gauges ?

  • @aarongray503
    @aarongray503 10 місяців тому +1

    Great video
    I have a field piece charge and air probes but I I have a yellow jacket 3 port manifold gauge set that I have had for years and use when I am charging and evacuating.

  • @jaredmclaughlin7806
    @jaredmclaughlin7806 Рік тому +2

    Hey brotha. I'm a rookie and need a starter kit. Liking the first Yellow Jacket Titan gauge you showed. I want a hard case to protect it because I'm always breaking stuff. Can you recommend a good starter kit for me including Manifold, Scale, Vacuum Pump sufficient for residential heat pump installation to light commercial, valve core removal tool, leak detector, micron gauges, etc. Obviously I'll probably have to purchase some of those items separately. But I just want to start off right. Don't want to be breaking my stuff. And I don't want to be waiting all day to vacuum out my line sets on larger systems with longer lines. Thank you sir!

  • @user-gc3lc8uv8v
    @user-gc3lc8uv8v 5 місяців тому +1

    I join 💪

  • @ryanpowell2908
    @ryanpowell2908 Рік тому +1

    I joined! Hello I'm Ryan from Louisville ky. 22 yes of residential and commercial installations and service. Self employed independent contractor.

    • @TaddyDigest
      @TaddyDigest  Рік тому

      Thanks for Subscribing
      Click here to join
      ua-cam.com/channels/uMyjTVlkM4xZ5z_eSyoB1w.htmljoin

  • @stanleykania7184
    @stanleykania7184 Рік тому +1

    I bought a Testo digital manifold with a case. Haven't used it yet. Just starting up a new business. Electric -HVAC

    • @TaddyDigest
      @TaddyDigest  Рік тому

      Awesome congratulations Hoping you have much success

  • @conspiraciesexposed7760
    @conspiraciesexposed7760 5 місяців тому +1

    Gunna get sman

  • @viperrr6886
    @viperrr6886 Рік тому +1

    Just ordered some 146 bucks but its the cheaper more original version but hopefully they last for a long time.

  • @markbell6864
    @markbell6864 2 роки тому +1

    Thanks for the info on your channel. Question, on a Samsung DVM S VRF system, for a ducted indoor unit slim or MSP, where do you tie in safety switch’s for an auxiliary float switch and switch for an aftermarket condensate pump? I know unit has the option for one and there is a float switch on the board but I didn’t do this. I do know if you can or not I can’t find anything of this. Any help would be greatly appreciated.

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      Hey mark great question
      I have an answer for this question
      I did 2 videos on this.
      I will send the links to you
      Please consider becoming a member thank you

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      ua-cam.com/video/z-ZcXRG_iHI/v-deo.html

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      ua-cam.com/video/OECATN0ZfYY/v-deo.html this is part 2

  • @leesellars
    @leesellars 2 роки тому +1

    Hello Tad Have you Tried the YJ P51 870 Gauge set well worth the money. Oh Im in the UK

    • @TaddyDigest
      @TaddyDigest  2 роки тому +1

      I have not tried that set looks like a good one though

  • @APHVAC0913
    @APHVAC0913 Рік тому +1

    What length of hose is better for the manifold 36"/48"/60"/72"?

    • @TaddyDigest
      @TaddyDigest  Рік тому

      Just standard hose size
      Whatever comes with the manifold

    • @APHVAC0913
      @APHVAC0913 Рік тому +1

      Thanks Ted 🙏👍

  • @hamzamo95
    @hamzamo95 Рік тому +1

    Hello, I got one of these off Facebook Market really cheap but without hoses, how and where do I go to get all the hoses needed to just work on my cars? Thanks

    • @TaddyDigest
      @TaddyDigest  Рік тому +1

      Here is a set of hoses amzn.to/415KDtM

    • @TaddyDigest
      @TaddyDigest  Рік тому +1

      Here is a adapter for a car
      amzn.to/3Iowosy

  • @WallStreet749
    @WallStreet749 Рік тому +1

    GARY JOINED 5-20-23

    • @TaddyDigest
      @TaddyDigest  Рік тому

      I don't see your name on the membership Is list
      Here's the link to join
      Join this channel to get access to perks:
      ua-cam.com/channels/uMyjTVlkM4xZ5z_eSyoB1w.htmljoin
      Wanna learn more about hvac? Check out my hvac tips for technicians playlist.
      ua-cam.com/play/PLVjetZt5xgenmO76adHwb2ctyeBIFKUus.html

  • @channelcatchaser9426
    @channelcatchaser9426 2 роки тому +1

    Man if you haven't tried Testo 550 you should.

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      I have not tried them but I will check them out

  • @winkawak
    @winkawak 2 роки тому +1

    I have a yellow jacket manifold with knob on the side. So its clockwise to close and counter clockwise to open.For some reason when i open the low pressure side, refrigerant are not being added. Any ideas?

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      I would need pics of your setup and I could help you. I will need on get your number. Let me know if you need help. Click the Join button and email me after at tadfuller1@gmail.com

    • @TaddyDigest
      @TaddyDigest  2 роки тому

      the middle hose yellow should be connected to the tank and the blue hose should be connected to the low side service port valve then the tank must be open and the knob on the left side of the manifold gauge should be open

    • @winkawak
      @winkawak 2 роки тому +1

      @@TaddyDigest thats correct but the issue is its not adding in refrigerant