How To Select Right MCB and Over Load Relay Size For Motor

Поділитися
Вставка
  • Опубліковано 5 лют 2025
  • How To Select Right MCB and Over Load Relay Size For Motor
    selecting the right MCB (Miniature Circuit Breaker) and overload relay size is crucial for safety and optimal performance. Learn the key factors and calculations involved in choosing the appropriate ratings to protect your motor and electrical system effectively.
    👍 If you found this tutorial helpful, please don't forget to like, share, and subscribe for more valuable electrical insights!
    🌐 Related Links:
    Hindi Channel @Electrical Technician
    / @electricaltechnician
    2nd Channel @Electrical Wiring School
    / @electricalwiringschool
    Short Video @Electrical Technician Shorts
    / @electricaltechnician02
    Telegram
    Instagram @ElectricalTechnician02
    / electricaltechnician02
    📧 Contact:
    Email: Electricaltechnician02@gmail.com
    📺 More Tutorials:
    MCB Vs MCCB
    • Difference Between MCB...
    Difference Between MCB, RCCB & RCBO Circuit Breaker
    • Difference Between MCB...
    How to Check Motor with Insulation Tester
    • Learn Practically How ...
    dcdb box connection for solar panel
    • dcdb box connection fo...
    #mcb #olr #electrical #starter #motor
    olr selection
    full load current
    mcb selection
    electrician
    relay setting
    overload relay setting
    overload relay selection for motor
    motor protection
    overload relay size selection
    contactor
    Motor starter selection
    Motor protection devices
    Thermal overload relay
    Motor starting current
    Short circuit protection for motor
    Motor control circuit
    Motor starter sizing
    Electrical circuit protection
    Motor control panel
    Motor protection relay
    Motor overload protection
    Motor starter wiring
    Motor control center (MCC)
    Motor overload trip setting
    Motor starter troubleshooting
    Motor control circuit diagram
    Motor protection switch
    Motor overload relay function
    Motor starter components
    Motor protection coordination

КОМЕНТАРІ • 24

  • @noelburke6224
    @noelburke6224 21 день тому

    Thank you very much ,you are clear and precise

  • @danielteyehuago1633
    @danielteyehuago1633 10 місяців тому +1

    I'm here again, thanks for sharing this with us

  • @dineshprajapati-k7h
    @dineshprajapati-k7h 9 місяців тому

    Wohhhhh Nicely & clearly Explained without any doubt........mazaaa aa gya Bohhat hi achhi information Seekhi Well Done ✅ Sir .....💖💖💖💖💖👌👌👌👌👍👍👍

  • @danielteyehuago1633
    @danielteyehuago1633 10 місяців тому +1

    Please come with a video of how to read and understand motor nameplate

  • @rsmoond
    @rsmoond 10 місяців тому +1

    Nicely explained

  • @billylun9634
    @billylun9634 8 місяців тому

    Thankyou btother you are a real geniuses. ❤🙏

  • @ReubenmxolisiNkosi-qn3di
    @ReubenmxolisiNkosi-qn3di 7 місяців тому

    Thank you this very clear ❤

  • @MES6664
    @MES6664 10 місяців тому

    Thank you for this video. I follow you from Chad 🇷🇴

  • @AlexWilliamJohn
    @AlexWilliamJohn 10 місяців тому

    It helped. Many thanks 😊

  • @owolabiadeteye5919
    @owolabiadeteye5919 10 місяців тому

    Thanks for this lecture boss

  • @rashidchibvuri2036
    @rashidchibvuri2036 10 місяців тому

    Thank you so much sir .. keep up the good work.

  • @AnasAl-Dhafiri
    @AnasAl-Dhafiri 10 місяців тому

    Many thanks sir for this amazing video

  • @danielteyehuago1633
    @danielteyehuago1633 10 місяців тому +1

    Please do you have a video on how to calculate a cable size for a load (motor) and how to select a contact for a load

  • @danielteyehuago1633
    @danielteyehuago1633 10 місяців тому

    Please can you refer me to the type of circuit breaker in your playlist

  • @jeffreywescott494
    @jeffreywescott494 7 годин тому

    Why did you not multiply (5 by 746)÷1000 to get kw?

  • @danielteyehuago1633
    @danielteyehuago1633 10 місяців тому +2

    I think the converting is figure 746 when the unit is in watt and 0.746 when the unit is in KW and not 0.75

    • @rasras2263
      @rasras2263 10 місяців тому +1

      That's what I thought also😂😂😂, this is new to me,, but I won't use it

    • @danielteyehuago1633
      @danielteyehuago1633 10 місяців тому

      @@rasras2263 thanks

    • @TheElectricalGuy
      @TheElectricalGuy  10 місяців тому +2

      we can consider 0.746 to 0.75 because the value will be almost similar of the both so to make the calculation easy we have to do so, if u don't want use 0.746

  • @orukodiappu7607
    @orukodiappu7607 8 місяців тому +1

    1hp=746watts

  • @destroychannel4796
    @destroychannel4796 10 місяців тому

    25 amp mcb for each phase?

  • @Jabez4087
    @Jabez4087 7 місяців тому

    Thank you but you miss efficiency of motor to find FLC . The write formula is
    I=p/√3*V*P.F*efficiency

    • @cmrr3099
      @cmrr3099 Місяць тому

      I also same question