CT Accuracy class : 0.2 vs 0.2S | Explained | TheElectricalGuy

Поділитися
Вставка
  • Опубліковано 7 лют 2025
  • In this video you will understand the difference between 0.2 & 0.2S accuracy class of current transformer. 0.2 & 0.2S are the metering CT accuracy class. This video explains the difference between the two as given in IEC Standard.
    ➜ CT Playlist - • Current Transformer
    ===============================================
    📌 Join me on Social Media
    Facebook ➜ / iamtheelectricalguy
    Instagram ➜ / the_electricalguy
    Electrical courses ➜ courses.theelectricaalguy.in
    ===============================================

КОМЕНТАРІ •

  • @RolandnZA
    @RolandnZA 8 місяців тому +8

    our videos are addictive! It's always a pleasure to watch them and to learn from you. Thank you for sharing!

    • @GauravJ
      @GauravJ  8 місяців тому

      Glad it was helpful 😇

    • @Abhinav-dm4gc
      @Abhinav-dm4gc 8 місяців тому

      Please make a video on circuit breaker control wiring ​@@GauravJ

    • @GauravJ
      @GauravJ  8 місяців тому

      Hello. I have a dedicated course on that. Visit - courses.theelectricalguy.in

  • @schrodingerscat1863
    @schrodingerscat1863 8 місяців тому +1

    This takes me back to my first job out of university designing HV metering and protection transformers at GEC. Designed dozens of these transformers and for something seemingly so simple they can be quite tricky to design especially the metering transformers. Used to have great fun testing them though seeing plasma building up around the primary when doing secondary over voltage tests on 400kV variants.

  • @michaeledwardharris
    @michaeledwardharris 8 місяців тому +1

    Excellent channel! I'm enjoying binge watching your videos. I'm a CS guy with an amateur interest in EE. Ty again. Very quality videos.

    • @GauravJ
      @GauravJ  8 місяців тому +1

      Glad it helped!!

  • @Charmingbanana696
    @Charmingbanana696 8 місяців тому +1

    Timings of your video are just amazing. I have thought in my head about this topic and notification pops up😂

    • @GauravJ
      @GauravJ  8 місяців тому

      Glad it was on time 😁

  • @kom6935
    @kom6935 8 місяців тому +7

    'S' stands for Special. The 0.2S class CTs guarantee the declared accuracy of +/- 0.2%, even with 20% loading.

    • @Сергей-щ6т6у
      @Сергей-щ6т6у Місяць тому

      in which IEC can I find this transcript so that it is specifically indicated?

  • @tanvirahamedsiddiquee8767
    @tanvirahamedsiddiquee8767 4 місяці тому

    Very Good Explanation

  • @samratsarkar6708
    @samratsarkar6708 8 місяців тому +2

    Kindly make a video on traction sub station. And why they take only two phase supply amd also mentioned it's impact on grid. Coz the load is only on two phase not in theee phawe one phase load is totally zero.

  • @srinivasaraoguggilam7355
    @srinivasaraoguggilam7355 6 місяців тому

    Very nice explanation 🙏🙏🙏

  • @jmorbasayan1901
    @jmorbasayan1901 6 місяців тому

    Thank you a lot. I hope there's more video and playlist about electrical equipment for substation

  • @chinsiongho
    @chinsiongho 6 місяців тому

    Hi Gaurav, are you able to explain how to select the correct metering CT ratio

  • @mujeebeloor7113
    @mujeebeloor7113 8 місяців тому +1

    Great 👍

    • @mujeebeloor7113
      @mujeebeloor7113 8 місяців тому

      Sir..Any vedio available for accuracy class for protection CT

  • @L-ASHWAKMOHIDEENK
    @L-ASHWAKMOHIDEENK 3 місяці тому

    hai
    I have a dout
    in this video the calculation in class 0.2 at 20% = 0.2*(20/100) = 0.04
    but in this video 0.2 at 20 % = 0.2*(20/100)=0.35
    kindly Explain with Calculation i am little bit Confused

  • @SUNIL_Kumar_1906
    @SUNIL_Kumar_1906 8 місяців тому

    What are the ratio error, composite error, phase angle error.... etc in CTs?
    Can you please explain?

  • @AchmadHanif-i5t
    @AchmadHanif-i5t 5 місяців тому

    Can we use class 0.2 ct to class 0.5 meter ?

  • @kantamaniteja3949
    @kantamaniteja3949 Місяць тому

    S stands for special as per my knowledge Sir

    • @Сергей-щ6т6у
      @Сергей-щ6т6у Місяць тому

      in which IEC can I find this transcript so that it is specifically indicated?

  • @a.r.vganeshraja7955
    @a.r.vganeshraja7955 8 місяців тому

    In CT nomeculture P1, P2 what its meaning can u elaborate pls

    • @GauravJ
      @GauravJ  8 місяців тому

      It indicates the primary winding..

  • @ravikumarnunna2830
    @ravikumarnunna2830 8 місяців тому

    What Difference between 0.1 nd 0.2s ? Where this 0.1 is used ??

    • @GauravJ
      @GauravJ  8 місяців тому

      Difference is in the limits of error allowed.

  • @chandrasekhar1290
    @chandrasekhar1290 8 місяців тому

    0.2s class error- 0.25% or 0.2%.

  • @chandrasekhar1290
    @chandrasekhar1290 8 місяців тому

    Pleaseclarify 0.2s class error- 0.25% or 0.2%.