  • Testing this battery charge/discharge control module in battery charge mode.
    www.icstation.com/voltage-pro...
  • Наука та технологія

КОМЕНТАРІ • 40

  • @skoda110
    @skoda110 Рік тому +2

    Cool unit. Can be used yo modify old school battery chargers(proper ones with transformer) and run them as automatic. May need separating the board and connecting voltage measurement directly from battery but does the job

  • @davidv1289
    @davidv1289 Рік тому +4

    Hours Expired Already 😂 Probably "health" as you suggested, that would be a handy feature for charging a known battery pack. An interesting device with many possibilities, thank you for sharing it with us. Regards, David

  • @scarpaz
    @scarpaz Рік тому

    Very cool little circuit one can buy for less than $10!

  • @SinKillerJ
    @SinKillerJ Рік тому

    That backlit LCD has become ubiquitous, I have seen it on so many relay modules, and in fact I have a thermostat relay with it.

  • @mr.makeit4037
    @mr.makeit4037 Рік тому

    Is that m5433 regulator used to regulate voltage to the display circuitry?

  • @nln1515
    @nln1515 6 місяців тому

    XY-CD60 manual
    1.Function:
    1>.Module supports 2 working modes: Charging Control P-1 and Discharging Control P-2.
    2>.Charging Control P-1: This mode is used for charging control to prevent
    overcharging.Display symbol IN indicates charging mode.
    3>.Discharging Control P-2: This mode is used for battery discharge control to prevent
    battery over-discharge and delay battery life.Display symbol OUT indicates discharging mode.
    4>.Battery voltage percentage: It is value get from battery voltage V, Lower Limit Voltage
    Value dn and Upper Limit Voltage Value UP. Calculation formula: V/(UP-dn).
    5>.Automatic parameter check: Screen will display and flashing ERR if the Lower Limit
    Voltage Value dn is more than the Upper Limit Voltage Value UP.
    2.Charging Control P-1 Mode:
    1>.Input terminal connect DC 6V-60V charger which use for battery.
    2>.Output terminal connect 1pcs DC 6V-60V battery. It will display 0.00V and nbE if the
    battery does not meet the requirements.
    3>.Output turn ON and the input charger starts charging the battery if battery voltage is less
    than the Lower Limit Voltage Value dn.
    4>.Output turn OFF and the input charger stops charging the battery if battery voltage is
    more than the Upper Limit Voltage Value UP.
    5>.The symbol IN will flashing when charging.
    6>.Support set parameters:
    6.1>.Upper Limit Voltage Value UP: Maximum voltage of the battery. Stop charging the
    battery if it exceeds this value. It is also the overcharge protection voltage value.
    6.2>.Lower Limit Voltage Value dn: Battery allowed minimum voltage. Start charging the
    battery when the battery voltage is lower than this value.
    6.3>.Charging Time OP:
    6.3.1>.Set battery charging time.
    6.3.2>.Turn ON charging time control function when the OP parameter value is more
    then 00:00. Minimum set time value 1minute.
    6.3.3>.Turn OFF OP control if set 00:00.
    6.3.4>.Start the timer when turn on output to start charging.
    6.3.5>.Module turn OFF output to complete a charging process when timing is
    completed.
    6.3.6>.Module automatically turns OFF charging time control function if battery
    voltage is less than the Lower Limit Voltage Value dn and flashing H:ER that means the
    unreasonable time parameter setting. It means insufficient charging and needs to continue
    charging the battery. Press any key to stop flashing.
    6.3.7>.Record and display charging time if disabled Charging Time OP when short
    press button SET. Clear time if at next charging or exit charging time display interface.
    6.4>.Turn ON Delay Time dOP: Set the delay interval between the first and the second
    charging. The time range is 0~999second.
    3.Discharging Control P-2 Mode:
    1>.Input terminal connect 1pcs DC 6V-60V battery.
    2>.Output terminal connect suitable load. Note the output voltage is same to battery.
    3>.Output turn ON and the battery starts to discharging if battery voltage is more than the
    Upper Limit Voltage Value UP.
    4>.Output turn OFF and the battery stops to discharging if battery voltage is less then the
    Lower Limit Voltage Value dn.
    5>.The symbol OUT will flashing when discharging.
    6>.Support set parameters:
    6.1>.Upper Limit Voltage Value UP: Threshold value to allow battery discharge.
    6.2>.Lower Limit Voltage Value dn: Battery allowed minimum voltage. Stop discharging
    when the battery voltage is lower than this value. It is also the over-discharge protection voltage
    value.
    6.3>.Discharging Time OP:
    6.3.1>.Set battery discharging time.
    6.3.2>.Turn ON discharging time control function when the OP parameter value is
    more then 00:00. Minimum set time value 1minute.
    6.3.3>.Turn OFF OP control if set 00:00.
    6.3.4>.Start the timer when turn on output to start discharging.
    6.3.5>.Module turn OFF output to complete a discharging process when timing is
    completed.
    6.3.6>.Module automatically turns OFF discharging time control function if battery
    voltage is more than the Upper Limit Voltage Value UP and flashing H:ER that means the
    unreasonable time parameter setting. Press any key to stop flashing.
    6.3.7>.Record and display discharging time if disabled Discharging Time OP when
    short press button SET. Clear time if at next discharging or exit discharging time display
    interface.
    6.4>.Turn ON Delay Time dOP: Set the delay interval between the first and the second
    discharging. The time range is 0~999second.
    6.5>.Discharge Turn ON Forced Start Time FOP:
    6.5.1>.This function is used to prevent the device from starting instantly and reduce
    the battery voltage, so that it is lower than the Lower Limit Voltage Value dn and causing the
    module to automatically turn off the output and causing the battery can not discharge properly.
    6.5.2>.The module will check the battery voltage again if enabled Discharge Turn ON
    Forced Start Time function.
    4.Button Description:
    1>.Long press means need keep press for more than 5second.
    2>.UP button:
    2.1>.Short press to switch display charging/discharging time and battery voltage
    percentage.
    2.2>.Long press to switch work mode. IN is Charging mode and OUT is Discharging mode.
    2.3>.Short/Long press to increase parameter value at parameter set mode.
    3>.DOWN button:
    3.1>.Short press to turn ON/OFF output.
    3.2>.Long press to turn ON/OFF display status L-P (power saving mode):
    3.2.1>.ON: Turn ON power saving mode. The display screen will turn OFF after
    5~10minutes.Press any button to resume display.
    3.2.2>.OFF: Turn OFF power saving mode. The display screen will keep ON all the
    time.
    3.3>.Short/Long press to decrease parameter value at parameter set mode.
    4>.SET button:
    4.1>.Short press to automatically switch/query display parameters UP/dn/OP/DOP at
    charging mode and UP/dn/OP/DOP/FOP at discharging mode in normal display interface. Short
    press to switch select parameter set in parameter set mode.
    4.2>.Long press to enter into parameter set mode.
    4.3>.Keep press about 5second to save parameter values.
    5.Use steps:
    1>.Connect right input voltage at VIN+ and VIN-.
    2>.Long press button SET to select work mode.
    3>.Short press button SET to switch parameters.
    4>.Short/Long press UP/DOWN to increase/decrease parameter value.
    5>.Keep press about 5second to save parameter values.
    6>.Remove input and connect load.
    7>.Connect right input voltage at VIN+ and VIN- again.

  • @flagpoleeip
    @flagpoleeip Рік тому

    Clear as mud.

  • @paulrautenbach
    @paulrautenbach Рік тому +2

    Julian, did you notice that for down the 7-segment display shows an upside-down Up, ie, dn?

  • @jeffflowers5489
    @jeffflowers5489 Рік тому +1

    I find that those relays may handle the rated current but they can't handle the initial spark and it eventually welds the contacts together.

    • @nginmumbetse7894
      @nginmumbetse7894 9 місяців тому

      Does the module have back EMF diode / spark suppressor capacitor etc, wired across the relay contacts, if not, could something be retrofitted?

  • @Coolcarting
    @Coolcarting 11 місяців тому

    Can you tell me how I can find one of those current limited power supply units?

  • @trishguitard
    @trishguitard Рік тому

    This product looks promising, I can't wait to try it out myself.

  • @jamhough22
    @jamhough22 Рік тому +2

    I suspect it stands for “health” because the timer ran out before it reached the lower voltage limit.
    That flashing display is really quite annoying.

    • @nginmumbetse7894
      @nginmumbetse7894 9 місяців тому

      Flashing display after low voltage disconnect, is why I came here, hoping to find magic incantation to turn it off or at least have it stop flashing after a period

  • @mr.makeit4037
    @mr.makeit4037 Рік тому

    HEA acronym means Happily Ever After. End of charging. Lol

  • @johnspringer4055
    @johnspringer4055 Рік тому

    High Elapsed Accumulation? 😄

  • @3DSpearfishing
    @3DSpearfishing Рік тому

    Are there any with SSR relay.?

  • @fredflintstone1
    @fredflintstone1 Рік тому

    Hmm did you say we will have another video to watch 😞

    • @JulianIlett
      @JulianIlett  Рік тому

      You will have more videos to watch until I retire :)

    • @andymouse
      @andymouse Рік тому +1

      Squeak !!!!!!!

    • @fredflintstone1
      @fredflintstone1 Рік тому

      @@andymouse Cheese!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!

    • @fredflintstone1
      @fredflintstone1 Рік тому

      @@JulianIlett Damn I may die before that then🙂

  • @RambozoClown
    @RambozoClown Рік тому

    Happily Ever After?

  • @igorfomenko9189
    @igorfomenko9189 23 години тому

    everything is good, except the fact that any relay is very unreliable, contacts can weld together

  • @darkknight145
    @darkknight145 Рік тому

    NBE is No Battery Voltage where E represents Voltage. Although the website you linked says "No Battery Connected"

    • @JulianIlett
      @JulianIlett  Рік тому

      No Battery Electromotive force - maybe :)

  • @mahboisph
    @mahboisph Місяць тому

    nBE = No Battery Equipment

  • @fortemezzo
    @fortemezzo Рік тому +2

    6 ads in 13 minutes. I stopped watching after that.

    • @JulianIlett
      @JulianIlett  Рік тому

      Welcome to UA-cam :)

    • @markeh1971
      @markeh1971 Рік тому

      Hi, try watching a film!
      Take care M.

    • @clixium
      @clixium Рік тому +6

      Plenty of ways to block commercials, I haven't saw an add on yt for years. I feel sorry for creators but yt made me do it

    • @SimonCoates
      @SimonCoates Рік тому +3

      Brave Browser is your friend. Built-in ad blocker.

    • @JulianIlett
      @JulianIlett  Рік тому +2

      @@clixium I'd rather make these videos than work at Tesco, but I'll do whatever puts food on the table :)

  • @Deaf_Lion
    @Deaf_Lion 8 місяців тому

    very good explain, now i need look for when solar feed battery that day time (LDR Light Dependent Resistor) switch on feed any on, till dark time switch off dont feed any, save battery for use other. hope you know what i mean.