Yes most likely this will still fix the issue. In this case the actual screen is still good but the circuit board probably got wet and thus some or all of the buttons don’t work.
I have an Intelliflo VSF and when we have a power outage, it looses the date and time. If you reset the time and date it will work again until the power drops off again. But now it will not even allow me the set the time or date. all the keys on the pad seem to work. Is the the Control Panel? If so I will buy one from you.
If it loses the time when you lose power, it means the capacitor in the drive has gone bad. This is likely not a control panel issue, it sounds like it's the drive itself.
How can I purchase the keypads and drive unit?
I need the board for 356879Z, a drive unit. Latest model. Can I get one from you?
It was very helpful
Thank you so much for this!
If the light on the keypad still illuminates, but none of the buttons work, is this still the fix for the keypad?
Yes most likely this will still fix the issue. In this case the actual screen is still good but the circuit board probably got wet and thus some or all of the buttons don’t work.
I have an Intelliflo VSF and when we have a power outage, it looses the date and time. If you reset the time and date it will work again until the power drops off again. But now it will not even allow me the set the time or date. all the keys on the pad seem to work. Is the the Control Panel? If so I will buy one from you.
If it loses the time when you lose power, it means the capacitor in the drive has gone bad. This is likely not a control panel issue, it sounds like it's the drive itself.
@@nuklear08 thank you for the information. Do you sell the drives?
@@dcoxrytonright now I only have drives for Intelliflo VS, not VSF
Ordered the part from you it worked great. Thx
Hi. Do you also have the pad for the whisper flow?
I do not unfortunately; only for IntelliFlo