  • @RoofingFacts
    @RoofingFacts 2 роки тому +4

    I'm shocked no one wanted to point out the plates were put in the wrong spot in over half the scenes, both per Carlisle specification and ANSI/SPRI.
    Plates are never supposed to be within 3" of edges of the insulation (or rather, when they are that close they don't provide the proper uplift resistance and another plate must be added in those area)
    They even mention the fastener should be at least 6" back then not 4 scenes later show plates along the edge.