School emergency diesel generator and automatic transfer switch test with real power failure test

Поділитися
Вставка
  • Опубліковано 5 жов 2024

КОМЕНТАРІ • 48

  • @spykillergames8402
    @spykillergames8402 Рік тому +12

    wow...a 4 cyl perkins...made in the UK..funny to see it all the way over in canada esp mated to a generator head....over here they were a go-to for small minibuses and tractors

    • @RDC_Autosports
      @RDC_Autosports Рік тому +1

      caterpillar bought em

    • @boostaddict_
      @boostaddict_ Рік тому +1

      they were common over here for tractors from the 50s to the 70s too

  • @peterryan7340
    @peterryan7340 Рік тому +7

    I am a hospital engineer in Australia. The generators we use take between 10 and 20 seconds to start for a black start (zero grid connection). 305kw turbo diesel Yanmar.

    • @nics-systems-electric
      @nics-systems-electric  Рік тому +3

      That's not bad at our local hospital here we have 4 caterpillar diesels 1500 KW each which the original contractor hired had them starting within around 12 to 18 seconds but the hospital complained it was too slow and had the generator company we deal with at the school district come in and make some changes and has them all starting and synchronized within eight seconds which is pretty impressive only three of the generators are needed to run the building so after a period of time the fourth will shut down

    • @peterryan7340
      @peterryan7340 Рік тому +1

      @@nics-systems-electric so no load shedding with that much power on tap?

    • @nics-systems-electric
      @nics-systems-electric  Рік тому +1

      @@peterryan7340 not exactly sure how much they are running there but assume pretty much everything with that large of a emergency supply the UPS's I'm sure only do critical loads to cover the start up time but I would have to assume other loads are likely almost all on generator power I haven't had a detailed walk-through on their system though so I couldn't tell you exactly just from what I've seen and heard

    • @peterryan7340
      @peterryan7340 Рік тому +1

      @nics-systems-electric we load shed our chiller units, have 80kwh storage for UPS until generator supply initiates. The only AC we have during grid failure is Operating Theatres and Communications Rooms. Our total load is actually very low as energy efficiency is critical nowadays

    • @nics-systems-electric
      @nics-systems-electric  Рік тому +2

      @@peterryan7340 that's interesting I'm assuming we keep our HVAC system running as well as elevators which are another huge load and all lighting that leaves me wondering what actually isn't kept going not sure if the generators there are 1500 KW at 600 V or at 208 V but either way it's a large supply it is pretty impressive that they have them starting in around eight seconds now I'm not sure why the hospital complained that the 12 to 18 seconds before was too slow as the UPS's should be more than capable of covering that time other than you may lose your general lighting for a short period of time

  • @jimmyssnowremoval1075
    @jimmyssnowremoval1075 Рік тому +4

    The place where I do facility maintenance at with 5 other engineers, we have 6 generators. The oldest one have is diesel the rest are natural gas and I asked when I first started is if there’s a disaster they’ll probably turn off the natural gas but on grounds we have a 200 gallon diesel tank to fill equipment wouldn’t it be better to run off diesel.

  • @joaquinfernandesgarcia996
    @joaquinfernandesgarcia996 11 місяців тому +1

    7:55 The generator has now entered its cool-down period

  • @BeezyKing99
    @BeezyKing99 Рік тому +2

    you weren't sure about the year of that generator, it's right on the tag you were looking at @10:16 May 1996, is when it was built.

  • @billyfowler9423
    @billyfowler9423 8 місяців тому +1

    That generator will last for many more years, runs smoothly, could probably power a lot more of the building with it.

  • @hqgirl567
    @hqgirl567 Рік тому +1

    The way the generator came on, it sounded like a truck turning on. But nice video

  • @Granth_Man
    @Granth_Man Рік тому +1

    Loves the 60hz sound at the beginning by the way the video is school

  • @GaryBeltz
    @GaryBeltz Рік тому +2

    That generator looks like it will need to be fueled soon that fuel gauge looked like it was at half or maybe a little over.

    • @nics-systems-electric
      @nics-systems-electric  Рік тому +2

      If the gauges is true I wasn't paying attention I didn't see one who knows if it's accurate

  • @AtticusMinecraft123
    @AtticusMinecraft123 Рік тому +2

    The power generator looks like hooting the car engine

  • @petra7306
    @petra7306 3 місяці тому +1

    Why is the generator so rusty

  • @jcc3279
    @jcc3279 Рік тому +1

    Nic, what model is that simplex panel in the backround. i heard it's trouble alarm go nuts during the transfer to emergency power. is it still being used or is it getting replaced with a new system sometime. just curious and greetings from Orlando, Florida.

    • @nics-systems-electric
      @nics-systems-electric  Рік тому

      4100 plus. no replacement planned yet

    • @jcc3279
      @jcc3279 Рік тому

      @@nics-systems-electric Thanks nic, also about your generator situation at home. I also don't have natrual gas service where i live in Florida but i do have a whole house generator but mine runs on a big propane tank in the backyard. just a thought for you at home dude. Came in handy when Hurricane Ian and Nicole hit my area. Power went out and less then 2 minutes max i was back online. My whole house gen is a 20kw kohler. Runs everything including my well, pool pumps etc.

    • @nics-systems-electric
      @nics-systems-electric  Рік тому

      @@jcc3279 yes that is an option if you have propane however due to the cost and limitations on how it's allowed to be stored gasoline was my only option

    • @jcc3279
      @jcc3279 Рік тому

      @@nics-systems-electric oh i understand but you could have a tank put in depending on costs but i know about how it's stored etc. we had our tank put in when we bought this place. wasn't cheap but it was so worth it.

  • @jeremiahhively3025
    @jeremiahhively3025 Рік тому

    Love these videos

  • @petra7306
    @petra7306 3 місяці тому +1

    I love you nic

  • @GaryBeltz
    @GaryBeltz 9 місяців тому

    Why does that school have two Fire Alarm panels? I see a Simplex at the beginning of the video then when you turn the power off I can see the EST fireshield.

    • @nics-systems-electric
      @nics-systems-electric  9 місяців тому

      There's three panels in total the simplex 4100 Plus is the main panel and the EST fire shield is the theatre panel that opens the roof and there is another panel in the commercial kitchen for the suppression system

  • @marksmith-ew7ir
    @marksmith-ew7ir Рік тому

    I think the same engine is in narrow board here in the uk.

  • @bradwilmot5066
    @bradwilmot5066 Рік тому

    The ammeter on the transfer switch is definitely pooched, as it didn't even twitch when it transferred over. The one on the genset itself is also likely bad... I imagine the transformers alone account for 10 amps or so, so sitting at essentially zero is bollocks.

  • @ebelray6890
    @ebelray6890 Рік тому

    I need one of these

  • @leafmk
    @leafmk Рік тому

    Huh Interesting stuff.

  • @henrydoesstuff213
    @henrydoesstuff213 4 місяці тому

    3:01 startup (sounds like a propane bus)

  • @thestihladdict1743
    @thestihladdict1743 Рік тому +1

    Looks like it transfered power before if even got up to operating speed(60hz) . Definitely weird 😆

    • @nics-systems-electric
      @nics-systems-electric  Рік тому +1

      Yeah it was pretty fast if it wasn't below 60 it had barely just got there this one doesn't wait around to make sure things are stable it just throws load at it lol

    • @thestihladdict1743
      @thestihladdict1743 Рік тому

      @@nics-systems-electric yeah. It just wants to comply with nfpa110 😂😂😂😂😂😂😂😂

    • @nics-systems-electric
      @nics-systems-electric  Рік тому

      @@thestihladdict1743 yeah which it doesn't even need to as it's a school lol

  • @UKsystems
    @UKsystems Рік тому

    Do the generators also get serviced?