#25 DC Generator - Cumulative compound Generator #2 - Terminal Characteristic ( Compounding types )

Поділитися
Вставка
  • Опубліковано 18 гру 2024

КОМЕНТАРІ • 18

  • @oneinabillion654
    @oneinabillion654 3 роки тому

    You are the only lecturer that explains If* is for theoretical purposes, but is not factually correct. I swear to god I love u.

  • @laltusing7802
    @laltusing7802 6 років тому +2

    Thanku so much sir for this selfless service❤️

  • @BaseYourBtech
    @BaseYourBtech 2 роки тому

    👍👍
    Sir as DC shunt generator, are the compound generators Vt also a double valued function?

  • @mukeahsolanki2901
    @mukeahsolanki2901 4 роки тому +1

    Excellent sir

  • @pramodpalellu9511
    @pramodpalellu9511 Рік тому

    An over-compounded dc generator i-s supplying 800 A at full load on 500 V. The resistance of each conductor is 0.02 ohm. The percentage of compounding is?
    Please give ans with formula

  • @qewqe5757
    @qewqe5757 4 роки тому

    thank you, great way of explaining :)

  • @cditanand
    @cditanand 6 років тому

    What is the no load characteristics curve for cumulative compound Gen.

  • @pulkitjain1426
    @pulkitjain1426 5 років тому

    How can we write total mmf = Nf × If*....if it is toatl mmf then why only Nf why not Nse.??

  • @saurabhgupta3024
    @saurabhgupta3024 6 років тому +1

    Amazing. Please explain how the load current is increasing? How have you assumed that if load current increases then armature current increases and so on. Because load current is produced due to armature current.

    • @ElectricalisEasy
      @ElectricalisEasy  6 років тому +3

      Remember this is a generator..the increase in load current means a demand of load which means a decrease in resistance of load..so the armature current would have to increase to give the demand load current...so it is not an assumption that load current increases...

  • @TheCharlesT01
    @TheCharlesT01 5 років тому

    A load for a compound generator is located one mile from the generator. The voltage at the load is to maintain as load is increased. Which compound generator is used?
    a) flat
    b) over
    c) under
    d) differential
    Can someone help me with this question please

    • @nagadeep_2369
      @nagadeep_2369 4 роки тому

      Flat compound may be to maintain constant voltage

  • @leenaukey2065
    @leenaukey2065 5 років тому

    If Ia is increasing then Ia(Ra+Rse) will also increase,A.R increases,flux weakening increases,flux reduces hence Ea reduces...
    What abt this??👆

    • @justadreamerforgood69
      @justadreamerforgood69 5 років тому

      Well, since the number of windings on the field are more than the armature so an increase in Ia would lead in an increase of field flux more than the increase of armature flux; net flux increases