How to find a number of bars in column | column'ல் எத்தனை கம்பி போடுவது என்று கண்டுபிடிப்பது எப்படி?

Поділитися
Вставка
  • Опубліковано 21 лип 2024
  • As per Indian standard (ISCODE 456:2000)
    There are limitations and regulations for column design.
    Limitations
    1. A column must have 4 numbers of bars.
    2. Minimum 12mm bars should be used in column
    3. stirrups should follow the rules below
    a. Least lateral length of the column
    b. 16 times dia of smallest longitudinal bar
    c. 300mm
    4. stirrups dia should be 1/4 of the longitudinal bar.
    5. Minimum 5mm bar should be used as a stirrup.
    In this video we deal with column reinforcements
    To find number of bars in column, we need to know how much load acting on the column and dimension of the column.
    Source:
    • How to decide the numb...
    www.iitk.ac.in/ce/test/IS-cod...
    civilsite.in/reinforcement-de...
    Contact for Construction Related Services
    Our Dream construction:-
    Saran Mayilnathan : +91 8667653803
    Rathish : +91 8667253687
    Services:-
    1. Material contract ( Sq. Rate ).
    2. 2D plan.
    3. 3D plan.
    4. 3D Elevation.
    5. Structural Design.
    6: Estimation.
    7. Labor contract with consultancy.
    8. Renovation works.
    Join this channel to get access to perks:
    / @civilonlycivil
    Advance civil engineering products:-
    Marking:-
    Laser machine: amzn.to/3Th25b6
    Advance spirit level: amzn.to/3Fq1kGT
    Dumpy level: amzn.to/3LjLrpo
    Leveling staff: amzn.to/3JDlzDE
    Total station : amzn.to/3YOMArW
    Auto adjustable prism: amzn.to/3lfQTio
    Right angle marker: amzn.to/3TepfyU
    Digital measuring tape: amzn.to/3lfqX6t
    My youtube setup:-
    My mobile: amzn.to/3TfwyGu
    My mic : amzn.to/3YTbeYy
    My tripod : amzn.to/3JaTW3a
    Light:amzn.to/3LoD5wA
    My PC setup
    Processor: amzn.to/3l8Obvb
    Gpu: amzn.to/3Ji3FoC
    Motherboard: amzn.to/3lfoLvL
    Ram: amzn.to/3mMEDpT
    Power: amzn.to/3YQeoMy
    SSD: amzn.to/3ZN6aGv
    Monitor: amzn.to/3JIkMBv
    keyboard : amzn.to/3JHEmOj
    Code book: amzn.to/3ZLPO0X
    But my suggestion
    camera : amzn.to/42p2Kvo
    Mic: amzn.to/3TgAYgg
    Tripod: amzn.to/3LpiqbH
    Light: amzn.to/42emdi7
    Matte : amzn.to/3TjlesV
    Matte: amzn.to/3JjEXEh
    Pc: amzn.to/3lir8hy
    Facebook: CivilOnlyCiv...
    Web:civilonlycivil.blogspot.com
    Instagram: civilonlyci...
    Twitter: / civilonlycivil
    Telegram: t.me/civilonlycivil (Use VPN)
    Linked In: / civil-only-civil-coc-0...
    For JOBS: Telegram link: t.me/joinchat/C6rlxI3m_d8wYjJl (Use VPN)
    chapters
    00:00 - starting
    00:35 - purpose of the column
    00:48 - Load and its types
    02:29- Area of steel
    03:49 - Example
    04:29- Axial load
    04:59- Gross area
    06:09- Main reinforcement equations
    08:33- Limitations
    09:11- How to find area of one bar
    10:32- Number of bars
    12:36 - Distribution bars
    13:06 - Spacing of stirrups
    14:26 - Contact details

КОМЕНТАРІ • 78

  • @nottoday9014
    @nottoday9014 Рік тому +7

    Vera level la teach panringa sir.ivlo naal unga videos lam UA-cam la recommend eh pannala

  • @bharathrambabu
    @bharathrambabu Рік тому +1

    Supera solli kuduthinga gurunatha nee valga

  • @sharanr1569
    @sharanr1569 4 місяці тому

    💆‍♀️finally i got your videos

  • @samvignesh620
    @samvignesh620 6 місяців тому

    Super explain bro thank you so much

  • @ashoksethupathy2189
    @ashoksethupathy2189 Рік тому +1

    Great brother

  • @vigneshbalaji591
    @vigneshbalaji591 Рік тому +1

    Good explanation bro..oru building manual ah structural design panni podunga bro

  • @subramaniyanshanmugam6186
    @subramaniyanshanmugam6186 Місяць тому

    Thanks bro hru 🎉❤ kovilpatti garpender❤

  • @rathishb4849
    @rathishb4849 Рік тому +1

    Bro....Elevation low budget la super ah irukanum athuku ethuna tips video podunga

  • @ramaaravinth004
    @ramaaravinth004 Рік тому

    spr bro very useful keep posting these kind of quality contents

  • @SamuvelK
    @SamuvelK Рік тому +1

    Centre line method estimate video podunga bro

  • @nagendranradhakrishnan4764
    @nagendranradhakrishnan4764 Рік тому

    Storage of building roll in column pl explain.

  • @fgasathish288
    @fgasathish288 Рік тому +1

    Bro super bro

  • @rockyrajesh317
    @rockyrajesh317 Рік тому

    Bro complete structural design for residential building notes...pdf..book .... Ethachu iruka bro..?

  • @vijaycivil3987
    @vijaycivil3987 Рік тому

    Super teach

  • @spmanicivil001
    @spmanicivil001 Рік тому

    How to calculate p value

  • @risvanahamed9113
    @risvanahamed9113 9 місяців тому

    Oru slab oda dead load yeppudy calculate pandrathu athuku column yeppudy Design pandrathu

  • @Keerthi-nt2ko
    @Keerthi-nt2ko Рік тому

    Bro same steel design beam ku oru video podunga bro

  • @rameshmmr4848
    @rameshmmr4848 Рік тому +1

    Bro 800kn load eppudi one column ku varuthunu oru video podunga bro

  • @PradeepPradeeppitchai-xd9sh
    @PradeepPradeeppitchai-xd9sh 9 місяців тому

    Tq you bro.

  • @dhileepan8706
    @dhileepan8706 Рік тому +2

    Super bro
    Load calculation podunka

  • @mohana3983
    @mohana3983 8 місяців тому

    நன்றி தம்பி

  • @manigandan2016
    @manigandan2016 Рік тому

    Bro job vacancy eruntha solunga

  • @fgasathish288
    @fgasathish288 Рік тому +2

    Andha load calculation pathiyum podunga bro .........detail ah explain panni

  • @ashoksethupathy2189
    @ashoksethupathy2189 Рік тому +4

    Kindly do videos related to rebar drawings, like how to draw rebar in pile cap, pier, etc

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      Sure we will discuss about pile and pile cap soon☺

  • @sendilpadu5072
    @sendilpadu5072 Рік тому +1

    Very very useful vedio sir thanks how we can find the loud in the colum

  • @KumaranMuthaiya
    @KumaranMuthaiya Рік тому

    Clg la kuda ipdi explain pannala. 👏👏👏

  • @shalomp1861
    @shalomp1861 Рік тому

    One KN என்பது எத்தனை கிலோ

  • @saravananbe1830
    @saravananbe1830 Рік тому

    Super bro
    Footing design videos podunga

  • @Thamaraiselvan-jm2ze
    @Thamaraiselvan-jm2ze Рік тому

    Do more videos

  • @yasaramanisha6285
    @yasaramanisha6285 Рік тому

    Spacing for beam also same method bro????

    • @civilonlycivil
      @civilonlycivil  Рік тому

      column ly spacing kandupudika innum silla methods irruku heavy structures vera mathiri dhan spacing provide pannanum.

  • @laadulabakkudossmemes1360
    @laadulabakkudossmemes1360 Рік тому +1

    Roof concrete podrathu...Ready mix concrete(RMC) best'ah illa Hand mix concrete best'ah. Which is economical??? Video podunga bro...its usefull to everyone

    • @civilonlycivil
      @civilonlycivil  Рік тому

      Sure 🥰🥰

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому

      Bro both cost will be similar only 5k difference will come. Manual mixing is best from my view

  • @nisha536
    @nisha536 Рік тому +1

    Structural drawing epdi podanum nu A to Z fulla solli kuduga anna

  • @dhanushkodi7861
    @dhanushkodi7861 4 місяці тому

    Bro 12"×9" column la 15 feet distance vidalama..?

  • @ramasamyv7697
    @ramasamyv7697 Рік тому

    Bro main rod ahh column la entha direction la kudukanumnu sollunga bro..
    Example ahh ippo oru 1x.75 post kku 6number of 12 mm kudukuromna atha 0.75 pakkam kudukanuma illa.... 1 pakkam 3 rod kudukanuma sollunga bro... Plz

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      Perpendicular to Longer span (unsupported length). 4 side la entha side la support oda distance adhigamo athuku perpendicular ah Rebar vara mathiri pathukalam.

    • @ramasamyv7697
      @ramasamyv7697 Рік тому

      Bro atha pathiyum detailahh video podunga bro....

    • @civilonlycivil
      @civilonlycivil  Рік тому

      @@ramasamyv7697 sure sure

    • @ramasamyv7697
      @ramasamyv7697 Рік тому

      @@civilonlycivil thank u bro

  • @ramasamyv7697
    @ramasamyv7697 Рік тому

    Ninga use pannirukka formula axial loaded column kku mattum than use akuma

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      Apdi illa, ella column ku ore formula dhan, but corner illa side la vara column ku unga load la irrunthu some % of the amount load increase pannaum.
      4 corner column mella vara load kooda, athanodala irrunthu 15 to 20 % load oda add panikanum , side la vara column ku mella vara load kooda athanoda load la irrunthu 11 to 15% ungaloda load kooda add panni kanum. Then atha P (load) ah unga formula la use pannanum.

    • @vigneshbalaji591
      @vigneshbalaji591 Рік тому +1

      @@civilonlycivil bro center la vara columnku thana load athikam varum corner la irukara columnku kammiyathana varum?

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      @@vigneshbalaji591 most of the case la apdi la dhan, but water tank la vara apo corner column hum athigamana load ah handle panna vendi irrukum. Corner column ku moment aagra thamai athigama irrukum adhanala antha load oda antha percentage of loads ah addition pannanrom.

    • @vigneshbalaji591
      @vigneshbalaji591 Рік тому +1

      @@civilonlycivil nice explanation bro .. detailing ungala maari solla mudiyaathu..oru building manual ah load calculation panni video podunga bro

    • @civilonlycivil
      @civilonlycivil  Рік тому

      @@vigneshbalaji591 thank for the feedback bro i try my best. 🥳

  • @learncivilengineering2927
    @learncivilengineering2927 Рік тому +2

    bro estimation series video podunga bro neraiya bbs laam pathi solli kudunga bro

  • @rajavinothkumar1960
    @rajavinothkumar1960 Рік тому

    Sir teach column position

  • @Manidhan-om2ih
    @Manidhan-om2ih Рік тому +1

    Bro 6* 9* inches column podalamnu sollirukanga appadi podalama illa 6* 12 podalama 6 rod sollirukanga (4x12mm 2x10mm )
    Hollow bricks la katturom

    • @civilonlycivil
      @civilonlycivil  Рік тому

      Illa, puriyala..

    • @Manidhan-om2ih
      @Manidhan-om2ih Рік тому

      1/2 * 3/4 size column podalamnu mester solluranga appadi podala illa 3/4 * 1 feet podalama column la 4*12mm rod 2*10mm rod podalamnu sollirukanga

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому

      @@Manidhan-om2ih minimum column size 9"x 9" ithuku keela poga kudathu.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому

      @@Manidhan-om2ih athey maari column ku minimum vertical bar 12mm provide pananum.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому

      @@Manidhan-om2ih Mullion ku matum 10mm use panalam athu wall length 3m ku mela pogum pothu Mulion provide panuvanga. Athu column illa but appdi act aagum for additional support.

  • @Ravismadurai
    @Ravismadurai Рік тому

    Bro chat gpt la intha answer varuthu bro kongam clarification Pannu ga bro
    Steel reinforcement for column
    
    Calculate the diameter and number of steel reinforcement required for a column size 230 × 300mm carrying an ultimate axial load 800 kN and the great of the concrete is m20 and Fe550d
    To calculate the diameter and number of steel reinforcement required for the given column size and load, we need to perform the following steps:
    Step 1: Calculate the cross-sectional area of the column.
    The cross-sectional area of the column can be calculated as follows:
    Area = Width x Depth Area = 230 mm x 300 mm Area = 69,000 mm²
    Step 2: Determine the compressive strength of the concrete.
    The grade of concrete given is M20. According to the IS 456:2000, the characteristic compressive strength of M20 grade concrete is 20 N/mm².
    Step 3: Determine the yield strength of the steel reinforcement.
    The grade of steel reinforcement given is Fe550d. According to the IS 1786:2008, the characteristic yield strength of Fe550d grade steel reinforcement is 550 N/mm².
    Step 4: Calculate the area of steel required to resist the given axial load.
    The area of steel required to resist the given axial load can be calculated using the following formula:
    Ast = (Pu x 1000)/(0.87 x fy)
    Where,
    Ast = Area of steel required (mm²) Pu = Ultimate axial load (kN) fy = Characteristic yield strength of steel reinforcement (N/mm²)
    Plugging in the values, we get:
    Ast = (800 x 1000)/(0.87 x 550) Ast = 1687.29 mm²
    Step 5: Calculate the diameter and number of steel bars required.
    Assuming that we will use only one steel bar, we can calculate the diameter of the steel bar required as follows:
    Area of one steel bar = (π/4) x d²
    where d is the diameter of the steel bar.
    Plugging in the values, we get:
    Area of one steel bar = (π/4) x d² 1687.29 = (π/4) x d² d² = (4 x 1687.29)/π d² = 2151.05 d = 46.37 mm (approx.)
    Therefore, we can use a steel bar with a diameter of 46 mm.
    Now, we can calculate the number of such steel bars required as follows:
    Number of steel bars = Ast/Area of one steel bar
    Plugging in the values, we get:
    Number of steel bars = 1687.29/((π/4) x 46²) Number of steel bars = 3.52
    Since we cannot use fractional steel bars, we need to use 4 numbers of steel bars.
    Therefore, the diameter of steel reinforcement required for the given column size and load is 46 mm and the number of steel bars required is 4.
    
    Calculate the 12mm diameter and number of steel reinforcement required for a column size 230 × 300mm carrying an ultimate axial load 800 kN and the great of the concrete is m20 and Fe550Sd
    2 / 3
    To calculate the number of 12mm diameter steel reinforcement required for the given column size and load, we need to perform the following steps:
    Step 1: Calculate the cross-sectional area of the column.
    The cross-sectional area of the column can be calculated as follows:
    Area = Width x Depth Area = 230 mm x 300 mm Area = 69,000 mm²
    Step 2: Determine the compressive strength of the concrete.
    The grade of concrete given is M20. According to the IS 456:2000, the characteristic compressive strength of M20 grade concrete is 20 N/mm².
    Step 3: Determine the yield strength of the steel reinforcement.
    The grade of steel reinforcement given is Fe550Sd. According to the IS 1786:2008, the characteristic yield strength of Fe550Sd grade steel reinforcement is 550 N/mm².
    Step 4: Calculate the area of steel required to resist the given axial load.
    The area of steel required to resist the given axial load can be calculated using the following formula:
    Ast = (Pu x 1000)/(0.87 x fy)
    Where,
    Ast = Area of steel required (mm²) Pu = Ultimate axial load (kN) fy = Characteristic yield strength of steel reinforcement (N/mm²)
    Plugging in the values, we get:
    Ast = (800 x 1000)/(0.87 x 550) Ast = 1687.29 mm²
    Step 5: Calculate the number of 12mm diameter steel bars required.
    We can calculate the area of one 12mm diameter steel bar as follows:
    Area of one 12mm diameter steel bar = (π/4) x d² Area of one 12mm diameter steel bar = (π/4) x 12² Area of one 12mm diameter steel bar = 113.1 mm²
    Now, we can calculate the number of 12mm diameter steel bars required as follows:
    Number of 12mm diameter steel bars = Ast/Area of one 12mm diameter steel bar
    Plugging in the values, we get:
    Number of 12mm diameter steel bars = 1687.29/113.1 Number of 12mm diameter steel bars = 14.92
    Since we cannot use fractional steel bars, we need to use 15 numbers of 12mm diameter steel bars.
    Therefore, the number of 12mm diameter steel reinforcement required for the given column size and load is 15.

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      in video what did i explain sample the AI Repeats.
      1. The load acting on the column,
      2.Area of column
      you will get ast.
      with the help of ast
      3. area of bar using.
      proved the bar as per ast requirement

  • @manikandanmani-zb1tl
    @manikandanmani-zb1tl Рік тому +3

    ப்ரோ , காலத்தில் stirrups கொடுக்கும்போது நடுப்பகுதியில் அதிகமான spacing,கீழ் மற்றும் மேல் பகுதியில் குறைவான spacing ஏன் கொடுக்கிறார்கள்

    • @civilonlycivil
      @civilonlycivil  Рік тому +3

      Shear force supports la adhingavum, mid space la kammiyavum irrukum so apdi tharanga..

    • @manikandanmani-zb1tl
      @manikandanmani-zb1tl Рік тому

      Ok bro, அந்த stirrups இடைவெளியை எவ்வாறு கணக்கிடுவது?

    • @civilonlycivil
      @civilonlycivil  Рік тому +1

      13:06

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому +1

      @@manikandanmani-zb1tl roof height la irrunthu l/4 split pannikonga antha length ku mattum stirrups spacing 100mm maintain panunga both floor and roof L/4 la balance area la stirrups spacing maximum aa irukalam but not exceeding 200mm.

    • @SathishKumar-th3bl
      @SathishKumar-th3bl Рік тому +1

      Example floor to roof height 3m
      3/4 is 0.75metre
      So floor bottom to 0.75metre ku close spacing of stirrups provide pannanum.
      Same roof side also.

  • @fakrudinahmed5141
    @fakrudinahmed5141 Рік тому

    Boss i will pay ur fees can u teach me design

    • @civilonlycivil
      @civilonlycivil  Рік тому

      Actually I was making a course, soon I will announce. 💓