Power and Energy Monitor Plug

Поділитися
Вставка
  • Опубліковано 1 жов 2024
  • A typical power and energy monitor that can be used with any plug in appliance. The main features are kWh and elapsed time. Also shows voltage, current, watts, VA and power factor.
    Patreon: / jwflame
    Ko-Fi: ko-fi.com/jwflame
    Website: flameport.com/

КОМЕНТАРІ • 91

  • @aidan2535
    @aidan2535 Рік тому +30

    Good to have you back JW. From a computer/electrical engineering student your videos are always fascinating. Please keep up the great work.

  • @kw1984
    @kw1984 Рік тому +36

    A new JW video!!!!!

  • @sergiofernandez3725
    @sergiofernandez3725 Рік тому +15

    Great to have you back on UA-cam JW. You are by far one of the best educators around. I watch your old videos all the time and still learn something new.

  • @olly7673
    @olly7673 Рік тому +9

    Wow JW! It has been far too long since we've seen you on YT.... welocme back. I'm looking forward to watching this latest instalment.

  • @theirisheditor
    @theirisheditor Рік тому +7

    Although domestic customers are not charged for reactive power here in Ireland, the smart meter ESB Networks recently installed on our supply (Omnipower single-phase meter ST) shows separate positive and negative kvarh readings as well as the billed day / night (11pm-8am) / peak (5-7pm) kWh readings.

  • @IndependentHeathen
    @IndependentHeathen Рік тому +6

    Hello JW it's good to see you.

  • @jensschroder8214
    @jensschroder8214 Рік тому +1

    Today the load in houses is either power factor 1 when the electric stove is on
    or more capacitive with other consumers.
    So it makes no sense to add another capacitor to compensate.

  • @Xclub40X
    @Xclub40X Рік тому +2

    JW I missed you pal.... Good to see you again me ol' bright spark 🔆

  • @StuWilloughby
    @StuWilloughby Рік тому +5

    He lives!

  • @spankysmp
    @spankysmp Рік тому +2

    Blimey. Where have you been?
    Glad to see a new video JW

  • @Handlebar-MustDash
    @Handlebar-MustDash Рік тому +3

    I have the Maplin version, many years old now but still very functional.

  • @Xclub40X
    @Xclub40X Рік тому +3

    JW is back..... let's all PLUG this video and get more to watch it

  • @jensschroder8214
    @jensschroder8214 Рік тому +1

    Refrigerators can be tricky. When the compressor starts, they need a starting current of 1000W.
    It's a few hundred watts to run. And then they are switched off again for a long time.
    If you want to operate this on an island system, you need a powerful 2000W inverter or more.
    But overall the power consumption is not that high.
    Inverter fridges don't have such spikes

  • @joesmith-je3tq
    @joesmith-je3tq Рік тому

    Good to see you posting again.

  • @mauanderuk
    @mauanderuk Рік тому +4

    Good to see a new video.

  • @clivequinn8978
    @clivequinn8978 Рік тому +4

    Great to see you again JW.

  • @andrewstewart5972
    @andrewstewart5972 Рік тому +3

    Good to see you back John. Spot on as usual.

  • @wayneski9103
    @wayneski9103 Рік тому +3

    Great to see you back JW. Love the videos

  • @SiaVids
    @SiaVids Рік тому +1

    I like to use my very dubiously constructed HOPI meter as everything is displayed at once on it.

  • @colinreid7305
    @colinreid7305 Рік тому +2

    Great to see your return.Informative video as always.

  • @GaryB007
    @GaryB007 Рік тому +5

    Good to see you back. I use that exact monitor plug.

    • @owensmith7530
      @owensmith7530 Рік тому

      I also have exactly one of these.

    • @Berkeloid0
      @Berkeloid0 Рік тому

      I hope JW will return it to you then when he's done, if that's the exact one you use 😝

  • @HIDLad001
    @HIDLad001 Рік тому +2

    This particular model is also sold in the US with a NEMA 5-15 plug as the Kill-A-Watt EZ. (they are both made by Prodigit Electronics.)

  • @ovalwingnut
    @ovalwingnut Рік тому

    244 VAC❗ 😵‍💫 In the US I generally stay clear of our house 120 VAC. Our 220 (to select machines) is a NO GO ZONE. To think you "guys" have that on almost every wall in your homes is... ShOcK & AWE impressive. R.E.S.P.E.C.T. Just saying. By the way I have a Kill-a-Watt and I didn't appreciate the additonal features until now. Thank you. Cheers!

  • @Killerspieler0815
    @Killerspieler0815 Рік тому

    PowerFactor has a use to destingush Computer power supplies: without PFC ( = the worst cheapest ones = Danger!) & witth Passive-PFC (old/cheap ones) & Active-PFC ( better one/modern ones)

  • @2760ade
    @2760ade Рік тому +1

    It would be great to hear your take on EVs, and the problems and division of opinion that they are currently presenting.

  • @Honest_Reviewer.
    @Honest_Reviewer. Рік тому +1

    Thanks for coming back to UA-cam... I always enjoy your videos.

  • @cannamorecamping5029
    @cannamorecamping5029 Рік тому +3

    I have this meter. I think mine came from Maplin. £12.50 in the sale. The buttons on mine have a mind of their own. Frustrating thing is it has no memory so as soon as the powers off you lose your data.

    • @Graham_Langley
      @Graham_Langley Рік тому +1

      I can confirm the price - mine was bought from Maplin 4/4/04 for £12-49 and still works perfectly.
      I've got a later one from Lidl with a three-button interface which has a 2x LR44 cell backup but you have to remember to take them out when not in use as they don't last that long.

  • @andrewtitcombe8378
    @andrewtitcombe8378 10 місяців тому

    I have one of these . But I can't find a way to test a mains power bank. As once the power bank shuts down the meter loses the measured KWH.

  • @e5Group
    @e5Group Рік тому +1

    Big Fan. Love the books behind. 💪👍👋❤️

  • @JivanPal
    @JivanPal Рік тому +2

    Good to see you back and also on Odysee!

  • @aamontalto
    @aamontalto Рік тому +2

    I’ve been binge watching your YT videos these past 2-3 weeks as I needed to add to my intellectual baggage. They’re a wonderful source of information thank you. But I noticed that you hadn’t posted a video for a while and this made me wonder. Very glad to see that you’re back.

    • @Alex1M6
      @Alex1M6 Рік тому

      "Intellectual baggage" What a wonderful phrase.

  • @voltare2amstereo
    @voltare2amstereo Рік тому

    35p that's silly expensive.

  • @bobfry5267
    @bobfry5267 Рік тому

    Welcome back from a fan in your neighbourhood.

  • @IcenI_Koi
    @IcenI_Koi Рік тому +1

    Welcome back John, been a while. Hope you are well ?

  • @lordpitnolen2196
    @lordpitnolen2196 Рік тому +3

    It has been suggested that smart meters could be used so that bills are based on Power Factor rather than Watts and would be more expensive.

    • @jwflame
      @jwflame  Рік тому +3

      Smart meters do record VA and power factor, so billing based on that is certainly possible.

    • @Berkeloid0
      @Berkeloid0 Рік тому

      I mean it's fair enough in some ways - the electricity company has to provide thicker wires and larger transformers to power loads with poor power factor without getting any extra payment in return - I guess it's just that it might be seen as unfair since suddenly you get charged more for the same appliances you've had for years. At least in the EU I believe there are more and more requirements about appliances that must have power factor correcting circuitry in them, so it might go two ways - either they will start charging for VA but it won't matter by then because everyone will have PFC appliances so minimal impact on one's electricity bill, or they might decide once everyone has PFC appliances there's no need to bother changing to VA billing because it won't bring in anything extra. Of course if you live in a country without a PFC mandate then surely it's only a matter of time...

    • @patrickwigmore3462
      @patrickwigmore3462 Рік тому +1

      ​@@Berkeloid0 The cost of maintaining the wires and transformers is (in principle) already covered by the current billing system. So, it's not necessarily unfair to the power company if metering doesn't take into account power factor. They're getting paid for it either way. It *is* _technically_ unfair to the customers who have the best power factor, because they are effectively subsidising those with the worst, but I imagine most homes are pretty similar, so the subsidy is probably quite small in practice.

    • @Berkeloid0
      @Berkeloid0 Рік тому

      @@patrickwigmore3462 I suppose that's a fair point. Since the current energy price should factor in those extra grid expenses, I guess you can argue that if they do start charging for VA, the energy price should drop to recognise that the highest PF consumers will make the network more efficient. Then the final electricity bill should come out the same for those who hover around the "average" grid-wide power factor, and the price would only go up for those with truly poor PF. That would be the fairest way to do it in my opinion, and yes of course we all know it would never happen like that!

  • @akdenyer
    @akdenyer Рік тому +1

    Great to hear and see you again. All the best John I am coming to the Uk for a week in September.

  • @videomaster8580
    @videomaster8580 Рік тому +1

    And on the third day JW rose again! Glad to see you back.

  • @grayrabbit2211
    @grayrabbit2211 Рік тому +1

    I've had a Kill-a-watt meter for ages... I also have an ancient monitor on the main panelboard which wirelessly transmits current kWh usage to a display box which also keeps historical usage stats. Very useful. Not sure what's available for that now.

  • @Swwils
    @Swwils Рік тому +5

    This man has the four volume Stubbs Waverly electrical encyclopedia on his bookcase and he means business.

  • @descultualexandru4022
    @descultualexandru4022 Рік тому

    Hello! welcome back! keep up the good work!

  • @NewWorldHoarder
    @NewWorldHoarder Рік тому

    I have both 230v and 110v power tools which are used in a non-regulated setting, not a building site etc. I consider the trade off in terms of safety vs convenience to be equal. However with rising and ridiculous energy costs, can I confirm that the 230v tool will be more efficient and thus less costly to operate than the 110v model?

    • @jwflame
      @jwflame  Рік тому

      The losses will mainly be in the 230-110V transformer. However even with that, any difference will be insignificant.

  • @IbrahimHalil-l9x
    @IbrahimHalil-l9x Рік тому +1

    We missed you, welcome back sir

  • @alanwhite4427
    @alanwhite4427 Рік тому +1

    It’s great to see you back, please keep up the good work

  • @steviecandtheplace2b
    @steviecandtheplace2b Рік тому

    I got mine from Maplin 😂

  • @2Sorts
    @2Sorts Рік тому +1

    The smart meter ‘in home’ monitor gives a whole house running total of course but not individual appliances.

    • @2760ade
      @2760ade Рік тому

      I use mine sometimes to work out the cost of say a washing machine cycle, or boiling a kettle. If you have little else running at the same time, as I do, it still gives you a rough idea!

  • @gbelectricks
    @gbelectricks Рік тому +8

    Nice to have you back JW👏
    That’s a good little product there. It makes you wonder if a bigger version of one of these (relatively cheap devices), is available to hard wire into the consumer unit, to monitor everything connected at the consumer unit. It certainly would make determining “maximum demand” a bit more accurate.
    How can they manufacture this for £20 then a power logger is up in the £3K range🤔

    • @jwflame
      @jwflame  Рік тому +3

      There are things like this for permanent installation: shellystore.co.uk/product/shelly-pro-4pm/
      4 channels, power monitoring and remote on/off control.

    • @ruben_balea
      @ruben_balea Рік тому +3

      There's also a really cheap DIN rail meter called D52-2066 that displays V, W, A, Hz, PF & kWh at the same time. It probably has the same precision as the cheap plug-in ones.
      It uses a current transformer that can be built in or external, but with any of them you have to disconnect the main live lead to feed it through the current transformer.
      These with current transformers are safer if they fail, other types are wired in series with the load and can melt or catch fire if the internal construction is shoddy, I would only trust one of that type if it's from a reputable brand.

  • @LoftInsulation-pj9dj
    @LoftInsulation-pj9dj Рік тому +1

    Wow a new video.
    Can you do a new video on tt systems?

    • @jwflame
      @jwflame  Рік тому +3

      What information did you want that isn't in the video from September 2021 on TT systems?

    • @LoftInsulation-pj9dj
      @LoftInsulation-pj9dj Рік тому

      @@jwflame oh right ill refer to that video cheers man.
      Also would it mean if im on a tt system would my neighbours be also tt aswell?

    • @jwflame
      @jwflame  Рік тому +1

      @@LoftInsulation-pj9dj Adjacent buildings should be on the same earthing system particularly if supplied from the same transformer or where there are conductive parts shared between them such as water pipes.
      Doesn't mean they always are, as plenty of installations are wrong. Some of that covered here ua-cam.com/video/S5OtLg6voZY/v-deo.html

    • @LoftInsulation-pj9dj
      @LoftInsulation-pj9dj Рік тому

      @@jwflame man your a good dude. $$$

  • @jaessak3463
    @jaessak3463 Рік тому

    Knowledgeable video.
    Where can I buy this Energy Monitor please.
    Thank you.

  • @Mike_5
    @Mike_5 Рік тому

    Nice bookshelf JW and jolly good PEM review

  • @thomasw6169
    @thomasw6169 Рік тому +1

    Great you are back. !

  • @UnstableVolt
    @UnstableVolt Рік тому +1

    JW is back! 💡

  • @roberthuntley1090
    @roberthuntley1090 Рік тому

    Any idea as to how accurate these are when fed with 'dirty' power supplies. I use a solar PV diverter (effectively an automatic 3 kW dimmer switch) to feed a 3 KW array of electric convector heaters, and used one of these to check on the diverter's own reported savings.
    If this meter is accurate, then the diverter display overreads by circa 13%. Just trying to see if that is a fair reflection when working on a highly distorted, 'dimmed' waveform.

  • @davepusey
    @davepusey Рік тому

    Still got one of these. Original from Maplin. Very handy.

  • @cainweber1978
    @cainweber1978 Рік тому

    John, please please take this to solar and wind power. Will Prowse is huge in USA doing this. Need a good UK equivalent.

  • @andygardiner6526
    @andygardiner6526 Рік тому

    Welcome back John. Keep up the good work.

  • @fje1948
    @fje1948 Рік тому

    It’s been a while John and I hope you are well. Good to see you are back!

  • @jon_273
    @jon_273 Рік тому

    A very useful device. Mine has even been used to help set the voltage and frequency on an oil platform amongst other things.

  • @easonwuc
    @easonwuc Рік тому

    Great to see you back.

  • @kye903
    @kye903 Рік тому

    Was very handy for making a spreadsheet to show my usage.
    The only issue is the cooker of course, since it doesn't have a plug. Does anyone make a device that can be fitted "in-line" between the twin & earth and the wall socket to show the usage of the cooker...?
    Or can a plug be temporarily fitted to the end of the twin & earth cable just for this purpose?

    • @merlin5476
      @merlin5476 Рік тому

      @Kye903 i personally wouldnt put a 13A plug on your twin & earth. I doubt you would get a 6mm cable in the plug & you can only draw 3000watts from your 13A plug ( it msy get warm over a period of time too.
      You may however be able to use either 1 hot plate or 2 at once or just the oven, but not more than 3000watts.

    • @Berkeloid0
      @Berkeloid0 Рік тому

      For those ones a more fiddly option could be to buy one of those cheap Chinese DIN rail mount power meters and a DIN rail enclosure to mount it in. They are available up to around 100 amps. Then you could put a 32A plug and socket on it and use it for measuring higher current devices like ovens. Not sure what the rules are over there but if you need a small 32 amp socket for permanent use you could consider buying an Australian domestic 32 A plug and socket, which are around the same physical size as the UK 13 A plug (with a different pin configuration of course). Then you could at least plug the oven into the wall without the power meter when you're done. Search for "as/nzs 3112" and pick the Wikipedia result if you want to see photos of how the different amperage sockets work.

  • @G1ZQCArtwork
    @G1ZQCArtwork Рік тому +1

    Welcome back after a long break, hope you are well. I was hoping you might mention SMART Meters, which it is rumoured will be shifting to charging for VA power factor soon, as a way of charging the customer more. This needs thrashing out down to basics.
    Cheers David in Lincolnshire.

  • @GM-dc8vr
    @GM-dc8vr Рік тому +1

    The incorrect capitalisation of kWh disturbs me.

    • @Berkeloid0
      @Berkeloid0 Рік тому

      Clearly it's measuring the Kelvin-Watt-Henry (KWH) of the load, giving you the temperature, rate of power consumption and inductance all in one convenient number!

    • @GM-dc8vr
      @GM-dc8vr Рік тому +1

      @@Berkeloid0 😂😂😂

  • @dollarama8652
    @dollarama8652 Рік тому +3

    🔦🔌💡⚡ Yay! a J.W video

  • @lawnmower1066
    @lawnmower1066 Рік тому

    Your video upload timing was excellent and came just in time.
    I was being talked into watching EastEnders!

  • @sedsberg77
    @sedsberg77 Рік тому

    Be careful with these on very high loads for very long times. Like EV-charging.

    • @cannamorecamping5029
      @cannamorecamping5029 Рік тому

      This one claims to be rated for 15amp I think. It also has an alarm if you overload it.

    • @sedsberg77
      @sedsberg77 Рік тому

      @@cannamorecamping5029 Even if the rating is adequate it can overheat over time because of bad quality or corrosion, pitting, dirt etc. on the plug contacts. And you lose one of the safety measures. The temperature sensor in the plug since you now basicly have two plugs. The charger/equipment and the meter. Here in Norway it's not even legal to charge with a plug at 5 amps on a 16A circuit. It has to be hard wired to a separate circuit.

    • @cannamorecamping5029
      @cannamorecamping5029 Рік тому

      @@sedsberg77 I'm actually using one to charge my ev. My ev is not a car though and the charger only draws about 500 Watts.

    • @rossthompson1635
      @rossthompson1635 Рік тому

      I have one that looks the same as this - the contact pressure on the pins of the plug is very poor and yes they do heat up quickly (or even flickers on and off). I keep meaning to take it apart and see if the sockets can be squeezed up a bit.