Dallas Fire-Rescue Engine Pump Test Procedures

Поділитися
Вставка
  • Опубліковано 21 жов 2024

КОМЕНТАРІ • 4

  • @stephenpoe2037
    @stephenpoe2037 Рік тому

    City of Santa Ana. ca. We did it all !

  • @AWDAuto
    @AWDAuto 3 роки тому

    Well, that's not correct.
    165psi over-run test is 10% over apparatus rated flow at 150. The 165 test should be immediately following the 150psi test, as it is to ensure the pump capacity is not at the "breaking point" during the 150 test.
    The 150 and 90 psi governor tests should be performed at their working pressures.

    • @kareemallmotor
      @kareemallmotor 11 місяців тому

      I was saying the same thing too after the 150 psi test should be 165 psi test 😅

  • @johnnysbricks483
    @johnnysbricks483 Рік тому

    They put a Pierce intake cap on a Spartan. 😂