Це відео не доступне.
Перепрошуємо.

Honda EU7000is Inverter Generator Running a 5 Ton AC

Поділитися
Вставка
  • Опубліковано 16 сер 2024
  • The Honda EU7000IS
    Amazon Link amzn.to/3rBwiVh
    is a super-quiet, fuel-efficient, long-running portable power solution. Equipped with Honda inverter technology to safely power computers and other sensitive electronic equipment. Low 52 to 58dB noise level is as quiet as normal conversation. CO Minder provides essential protection from harmful carbon monoxide. Bluetooth connectivity lets you monitor the generator from your smartphone. Covered outlets protect against the elements. Plus, the iMonitor digital display shows hours of use, performance data, battery charging status
    Features + Benefits
    Low 52dB @ 1/4 load and 58dB @ rated load
    iMonitor digital display shows hours of use, performance data, battery charging status and other on-board diagnostics
    Runs up to 6 hours @ rated load and up to 18 hours @ 1/4 load
    Eco-Throttle™ reduces noise and fuel consumption
    Oil Alert® protects the engine
    Includes battery, wheel kit with large semi-pneumatic tires and folding handles
    CO Minder provides essential protection from harmful carbon monoxide
    Covered outlets protect against the elements
    Bluetooth connectivity lets you monitor generator from smartphone
    Four 20 Amp GFCI outlets meet ETL and NEC standards
    Key Specs
    Item# 100557
    Brand Honda Power Equipment
    Manufacturer's Warranty 3 year limited warranty
    Ship Weight 262.0 lbs
    Surge Watts 7000
    Rated Watts 5500
    Fuel Type Gasoline
    Engine Model GX390T2
    Engine Honda GX390T2
    Engine Displacement 389
    Noise Level (dB) 52 at 1/4 load; 58 at rated load
    Start Type Electric
    Fuel Capacity (gal.) 5.1
    Run Time 18 hrs. at 1/4 load; 6.4 hrs. at rated load
    Receptacles (qty.)
    (4) 20A 120V, (1) 30A 120V locking plug, (1) 30A 120/240V locking plug
    Low Oil Shutdown Yes
    CARB Compliant No
    Product Weight 262 lb
    Dimensions L x W x H (in.) 33 1/2 x 27 5/8 x 28 1/2

КОМЕНТАРІ • 59

  • @jvazquez53
    @jvazquez53 Рік тому +9

    I bet Honda is coming up soon with something even better, they have only done a few improvements on the EU7000is in the last 5-6 years. The competition is getting stiff but no one has gone 100% to the Honda level. One thing that none has and Honda does: reliability.

  • @rebellucy6200
    @rebellucy6200 Рік тому +8

    Pound per pound the Honda EU7000 is the best generator of all time.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      Hey RebelLucy
      👍🏾👊🏾😎💯

    • @TheBry_Guy
      @TheBry_Guy Рік тому +2

      I have to agree. I have one and it started my 2.5Ton AC without a softstarter with no issues. I installed one anyway and there is barely a hiccup when it kicks on. I use it with the "Generlink" connector to the house. I tried a buddy's standard 8000W generator and my LEDs had a flicker to them and my Battery backup UPS for my office (computers/router etc) kept beeping if the AC kicked on, or the stove element kicked on. The Honda had none of these issues. And the Honda can run in my driveway or backyard and I can't hear it with the windows closed (A/C running). Hardest part with the Honda is getting one as they are hard to find in my area (Ontario Canada).

  • @heep34987yt
    @heep34987yt 11 місяців тому +1

    You know Honda is the best when you hear competitors say theirs is just as good or better than the Honda. Seems Honda is the bench mark. If Honda is too expensive then simply don’t buy one.. but you must admit the quality is there. For those that probably won’t regularly use a generator, a less expensive brand is a wise choice.

  • @johnclyne6350
    @johnclyne6350 Рік тому +1

    Thanks for posting Gavin, 👍🏻👊🏻👏🏻
    You might see my comments on others that create videos on the same generator. I personally have the same generator. Just an older model. Mine doesn’t have the blue tooth capability nor the CO minder. Mine runs full rail all the time with the eco throttle off. I don’t need the CO minder because mine is permanently outside my house in it’s own “house” if you will.
    I had an electrician install an interlock in my circuit breaker panel like your set up. Instead of an inlet on the side of your house? I have my inlet inside the generator house. That way no one can tamper with the generator or the cord. Mine is grounded to a ground grid. Something you might consider if you plan on leaving your generator on for long periods of time. (There is a ground lug on the frame below the control panel on the right hand side). Generators can create static electricity & if let to run for extended periods of time could shock whoever touches the metal part of the generator. Hence the ground lug. Consult an electrician about grounding your chassis.
    I’m a firm believer that the Honda EU 7000 is is THE BEST generator on the market! Lots of folks like to compare their generators to the Honda but Honda continues to be the innovator. I currently have a hard start capacitor that I had installed for my older Trane 2-1/2 ton condenser. I have heard great things about the soft start. Next time my A/C mechanic is at my house I’ll have them swap that out.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      Thanks John thanks for watching
      The Hondas are great generator pretty much you buy one for life

  • @Marcus2750-u1t
    @Marcus2750-u1t Рік тому +5

    As usual great content Gavin! Hondas are always the king IF you can afford one! But if you can swing it they are great! Thanks as always! 💪🏿👍🏿

  • @Tom-In-Ga
    @Tom-In-Ga Рік тому +2

    Nice demo. I wish all generators were that quiet. I've got to invest in one of those soft starts for my RV. It would be nice to run one of my A/Cs with my little generator. But, prices are going higher and my income isn't. I'll have to add it to my Christmas wish list for now.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +2

      Hopefully the AC manufacturer just start incorporating the soft start to their units

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +2

      Thanks Tom👍🏾💯

  • @robertrussell1141
    @robertrussell1141 Рік тому +1

    Honda products are absolutely awesome but you pay the price for quality!!!!!

  • @Rockrewls
    @Rockrewls Рік тому +1

    The Honda is impressive, and it did do it better then the Yamaha although the Yamaha was impressive considering its a bit smaller inverter.

  • @KevinRedmondWA
    @KevinRedmondWA Рік тому +4

    This video shows you just how good the Genmax 6000 is to be honest. Fraction of the price, 240V output, and running watts of 5250 which is just shy of this Honda. The Genmax also weights a lot less and just as silent. The only bad part is probably the reliability, if it breaks I’ll just buy another one because it’s cheap. Oh, the Genmax 6000 is also dual fuel.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +6

      Just wait till you see what Genmax has coming out!! ohhh it’s Awesome I can’t wait!!!

    • @KevinRedmondWA
      @KevinRedmondWA Рік тому

      @@GeneratorReviews I know right. Another point for Genmax's price. When the new sposely 7000IED comes out, if the weight is about the same, and selling the 6000 would be super easy because of the low price point.

    • @josesantiago9287
      @josesantiago9287 Рік тому

      @@GeneratorReviews You don't know when is coming the new genmax?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      @@josesantiago9287 I don’t have an exact date but hopefully it’s pretty soon maybe next month

  • @mikesheridan2
    @mikesheridan2 Рік тому

    Surprisingly, My Honda 7000 can handle one of my two ac units at a time... There is a surge when it kicks on but then settles down and runs... When our power is out we run the downstairs AC during the day, and the upstairs AC during the night... This is without a soft start on either unit... I don't understand how or why it works but I'm thankful it does...
    Obviously your mileage may vary...

    • @briangarza7273
      @briangarza7273 4 дні тому

      What size are your ac units? I have a 5 ton down and 2 ton up Carrier and considering soft starts with a Honda EU7000.

  • @douglasmontgomery6315
    @douglasmontgomery6315 Рік тому +2

    David, nice video. We talked about fuel efficiency at different loads. Maybe future testing could incorporate GPH estimate powering loads ?
    Thanks again

  • @Rockrewls
    @Rockrewls Рік тому

    Gavin, I would love to see you load test this on your RV and throwing as much at it as it can take.

  • @browsedeweb8834
    @browsedeweb8834 Рік тому

    I'm glad you redid this video. Still not sure if I should try my EU7000is with my 4-ton with EasyStart 368. The bluetooth app shows my startup as 55A with the easy start, but running is about 14A. This means the Honda would have to surge to about 11kw to meet the inrush.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      The 55 A is coming from the soft start capacitor whatever the Honda gives it will make up the difference

    • @browsedeweb8834
      @browsedeweb8834 Рік тому

      @@GeneratorReviews Well, I hooked up the generator today and tried to start the 4-ton HVAC with the EasyStart and it didn't work. The EasyStart errored out. I was using gasoline with eco mode off and all breakers off except the air handler and the condensing unit. I set the fan to on instead of auto and it was drawing about 300W per leg. Then I set the thermostat lower and the AC tried to kick in but only the fan on the condensing unit ran. The compressor wouldn't run. I tried it twice with the same effect. After unhooking the generator and putting utility power back, the HVAC worked fine, with last startup on the EasyStart app showing 50A. Just too much for the Honda.

    • @GeneratorReviews
      @GeneratorReviews  Рік тому +1

      @@browsedeweb8834 you’re probably gonna have to let your EasyStart learn for a while before trying again

  • @christurner5473
    @christurner5473 Рік тому

    Great video Gavin please keep them coming I learn something new every video you post

  • @MJF40
    @MJF40 Рік тому +2

    Which generator at any price range in this segment feels like a tank in build quality beside this one ?

  • @jonlee5642
    @jonlee5642 Рік тому +2

    Holy quiet. I thought my duromax 9000 inverter was quiet. But damn

  • @briangarza7273
    @briangarza7273 4 дні тому

    What is your ac RLA and LRA nameplate values? I have a 5 ton Carrier with 26.4 and 134. I am considering a setup like yours but not sure if it will work.

  • @troy3456789
    @troy3456789 Рік тому

    I am looking for someone on youtube observing the energy that comes from this Honda with an oscilloscope to see just how nice the output waveform really is. I tried calling Honda early yesterday to ask about the Honda EM6500SX, and their help line employees do not have a clue if it is a modified sine wave or a pure sine wave output. Honda does not prominently display the type of output on their boxes or in their literature (modified sine wave or pure sine wave). I do not know why they keep it a secret.

  • @SNeal5966
    @SNeal5966 Рік тому

    This is a nice Generator, but man this thing is Spendy. I could not justify this price but would love to have it.

  • @MarvSomera
    @MarvSomera 7 місяців тому

    I came across your video which I found very helpful in installing my own EasyStart for my 4 ton AC unit. My next step is to figure out which generator to get. Can you let me know what is the InRush reading of your 5 ton AC unit that Honda EU7000is was able to run? Thanks in advance!

    • @GeneratorReviews
      @GeneratorReviews  7 місяців тому

      I don’t think the 7k will be enough to get the job done but a 9000w or 10500w works perfectly.
      My inrush for the 5ton was 132 before the soft start.

    • @MarvSomera
      @MarvSomera 7 місяців тому

      @@GeneratorReviews My 4 ton was at 130 before the EasyStart. After installing the EasyStart, it's been consistently pulling 42 start peak amps. I was hoping that the EU7000is could work.

  • @jacquelinelinville-brown3221
    @jacquelinelinville-brown3221 Місяць тому

    Hello Gavin, I am trying to find a inverter generator 220/240 watts and 50hz as I will be using it in Jamaica, please help me to find one

  • @allencar5212
    @allencar5212 Рік тому

    Is your AC a 2-stage compressor? That makes a big difference. My 4-ton Goodman is 2 stage. It pulls 10.1/12.8 amp for 1st and 2nd stage but the inrush current is normally 122 amps measured with a clamp-on meter. But adding a hard start kit reduced the inrush to 63 amps. At that level my generator which can produce 6850 watts on Nat.Gas could start the AC compressor if the inside fan was already running and nothing else was on in the house.

  • @jortega222
    @jortega222 Рік тому

    Galvin, great video! Thank you! I like to know if you will be reviewing the DuroMax 12000 Watt / Max 15000 Watt Portable Generator Dual Fuel Hybrid Electric Start | XP15000EH? Or if you have, please paste a link. Also, I wonder if you've looked at the Generator Zombie Box. This product looks great but wanted your thoughts or review on this product. Thank you so much!

  • @davemacy-cm2st
    @davemacy-cm2st Рік тому

    Can I wire this to the new eu32 also so that I have a full 10K I can send to the panel? I'm going to put my interlock kit on later this week. Wanted to wait for an electrician but they charge too much so am following youtubes. thanks

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      I don’t know if one being only 120 V and the other one being 240 V that might be a problem.

  • @carlosreyes6448
    @carlosreyes6448 Рік тому

    Do you turn your breaker switch off before you turn. You're generator off? Or after?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      Just the large loads I make sure the central air is off since it’s the largest one

    • @carlosreyes6448
      @carlosreyes6448 Рік тому

      @@GeneratorReviews oh okay so I've been, trying to figure out why my eu7000is. Would overload when I turn my 3.5 ton ac on. Sometimes it works and sometimes it doesn't. So I need to have the circuit protector off when I turn. My ac on?

  • @Big-Rouge
    @Big-Rouge Рік тому

    Hey Gavin, do you think the Honda could run your 5 ton AC & blower for hours without overloading? Thanks for all your testing videos!

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      I think the 9000 watts does a better job when it comes to powering the 5 ton ac for long periods of time

  • @ZahoorAhmadyadoo-zf4wx
    @ZahoorAhmadyadoo-zf4wx 9 місяців тому

    Can we run 5hp electric moter
    On hydralik meachen

  • @chg2799
    @chg2799 Рік тому

    Do you think the EU7000 will run a 3.5 ton AC without a soft start…?

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      No, I don’t think it will won’t have enough amps to start the AC compressor

  • @jonlee5642
    @jonlee5642 Рік тому

    Why does this sound quieter then my duromax 9000xp but it's the same DB

    • @GeneratorReviews
      @GeneratorReviews  Рік тому

      🤔ahhh Because it’s quieter than the Duromax the Honda and the powerhorse are crazy quiet

  • @JaasenJones
    @JaasenJones Рік тому

    Will it run your oven, or dryer?

  • @Sleepvroffical
    @Sleepvroffical Рік тому

    Mine only gives me trouble. Im about to chunk it!!!