How to Install a Double Switch for a Bath Light and Fan

Поділитися
Вставка
  • Опубліковано 30 вер 2024
  • Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Amazon Prime Video Channel Free Trial: amzn.to/3mwgUEW
    Fluke -A1-II Volt-Alert AC Non-Contact Voltage Tester: Amazon.com: amzn.to/13Tw7CY
    IDEAL 61-534 Digital Circuit Breaker Finder with Digital Receiver and GFCI Circuit Tester: Amazon.com: amzn.to/2ql9yYz
    Wago (100) 221-412 (50) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2WxqHxC
    Wago (25) 221-412 (25) 221-413 (25) 221-415 Lever-Nut Assortment Pack: Amazon: amzn.to/2HR6rDY
    Wago 221-413 LEVER-NUTS 3 Conductor Compact Splicing Connectors Qty 50: Amazon: amzn.to/2HMeYIr
    Wago 221-412 2-Conductor Compact Splicing Connectors (Pack of 100): Amazon: amzn.to/2Oy3Qzm
    Wago 221-415 LEVER-NUTS 5 Conductor Compact Splicing Connectors Qty 25: Amazon: amzn.to/2JSqNP9
    Knipex Tools 13 88 8 US Electrical Installation Pliers: Amazon: amzn.to/2H2rxxm
    Wiha 30747 Insulated SlimLine Xeno Driver #2, 6.0mm Blade Diameter: Amazon: amzn.to/2ILWlUn
    Wiha 32092 Slotted And Phillips Insulated Screwdriver Set, 1000 Volt, 6 Piece: Amazon: amzn.to/2GRRfF7
    Leviton 5634-W 15 Amp, 120/277 Volt, Decora Single-Pole, AC Double Switch, Commercial Grade, Grounding, White: Amazon: amzn.to/2DBB50v
    Ideal Grounding Pigtails with Ground Screws (Pack of 50): Amazon.com: amzn.to/2asJXUV
    Shown in the video: Leviton 5691-2W 15 Amp, 120/277 Volt, Decora Plus Rocker Single-Pole AC Quiet Switch, Commercial Grade, White: Amazon: amzn.to/2GNfTq5
    Leviton GFTR1-W SmarTest Self-Test SmartlockPro Slim GFCI Tamper-Resistant Receptacle with LED Indicator, 15-Amp, White: Amazon: amzn.to/2Uvzm7c
    Leviton T5325-WMP M22-Straight Blade Tamper Resistant Duplex Receptacle, 125 V, 15 A, 2 Pole, 3 Wire, 10-Pack White Piece: Amazon: amzn.to/2Xrnyjn
    Fluke 117 Electricians True RMS Multimeter: Amazon.com: amzn.to/2s0aa70
    DEWALT DCK278C2 ATOMIC 20-Volt MAX Lithium-Ion Brushless Cordless Compact Drill/Impact Combo Kit: Amazon: amzn.to/2ZJeHf9
    DEWALT DCF887B 20V MAX XR Li-Ion Brushless 0.25" 3-Speed Impact Driver: Amazon: amzn.to/2HOkWbs
    DEWALT DCV581H 18/20-Volt MAX Cordless/Corded Wet-Dry Vacuum: Amazon: amzn.to/2IiCJrz
    Leviton T5832-W USB Charger/Tamper-Resistant Duplex Receptacle, 20-Amp, White: Amazon: amzn.to/2IFOIix
    Leviton 16342-W 20-Amp, 125-Volt, Decora Plus Duplex Receptacle, Straight Blade, Commercial Grade, Self Grounding, White: Amazon: amzn.to/2XqVUD9
    IDEAL Industries 61-164 SureTest Circuit Analyzer: Amazon: amzn.to/2Da3TwM
    Ideal Industries 61-183 Alligator Clip Adapter for SureTest Circuit Analyzers: Amazon: amzn.to/2PjywVn
    Shipping, Entertainment, Music etc. Discounts:
    Amazon Prime Student 6 month Free Trial: amzn.to/2J4txZw
    Prime Video Channel Free Trial: amzn.to/3mwgUEW
    Amazon Prime 30 Day Free Trial: amzn.to/3mqTcdq
    Amazon Music Unlimited Free Trial: amzn.to/35IlgC6
    Discount on Amazon Prime: amzn.to/37ZJmLN
    Audible Gift Membership: amzn.to/31Oxb08
    Try Audible and Get Two Free Audiobooks: amzn.to/37NMydc
    Amazon Business Account: amzn.to/31NGgGw
    Amazon Kids+ : amzn.to/2J6xFIt
    Exclusive benefits on Twitch: amzn.to/2HCWNpN
    Amazon Home Services: amzn.to/3jxIFez
    Kindle Membership Plans: amzn.to/31O9Pro
    Amazon Prime as a Gift: amzn.to/3jxxF0U
    Create an Amazon Wedding Registry: amzn.to/3jyHL1m
    Create an Amazon Baby Registry: amzn.to/35CGa5K
    My Gear and Software:
    The video was taken with the: PANASONIC LUMIX GH5 Body 4K Mirrorless Camera, 20.3 Megapixels, Dual I.S. 2.0, 4K 422 10-bit, Full Size HDMI Out, 3 Inch Touch LCD, DC-GH5KBODY (USA Black): Amazon: amzn.to/2VvWVcV and the PANASONIC LUMIX Professional 8-18mm Camera Lens, G LEICA DG VARIO-ELMARIT, F2.8-4.0 ASPH, Mirrorless Micro Four Thirds, H-E08018 (Black): Amazon: amzn.to/2Yem0JO
    This video was made using the: Transcend 64GB Class 10 SDXC Flash Memory Card (TS64GSDXC10E): amzn.to/1w02Oxn
    Bill and sparkychannel.com are participants in the Amazon Services LLC Associates Program, an affiliate advertising program designed to provide a means for sites to earn advertising fees by advertising and linking to Amazon.com

КОМЕНТАРІ • 94

  • @garydudgeon
    @garydudgeon 3 роки тому +4

    Great explanation Sparky.

  • @pointbreak8293
    @pointbreak8293 3 роки тому +4

    Bill, seems as if you always get the older generation switches to replace and get up to code... you’re the man... awesome video as usual sir.. have a great rest of your week and stay safe...👍👍👍

  • @Eddy63
    @Eddy63 3 роки тому +2

    Hey Wild Bill , which is more exciting to work on ? Paint filled slotted screws or really short wires ? Lol ... And yes Knipex are very proud of their tools ... Great vid as usual ...

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      LOL! Well this box had both a short wire and paint filled screws so it was extra fun! Thanks Eddy!

  • @kenbrown2808
    @kenbrown2808 3 роки тому +2

    the best trick I've found for getting paint out of a device screw slot is to first find the slot by chipping off the outer layers with your electrician's chisel (flathead screwdriver) and then line up the screwdriver at the end of the slot, against the paint filling the slot, and then drive it sideways through the slot with your electrician's hammer (9" lineman's pliers)
    this will usually pop the paint free of the slot and take it out cleanly. it also frequently breaks the rust on the screw loose from the rust on the box and makes it easier to back the screw out. if it is still tight, it can sometimes be started easier by seating the driver in the slot, and gently rapping on the handle while you turn the screwdriver.

  • @bananaaaa3428
    @bananaaaa3428 3 роки тому +2

    Hey guys I noticed a lot of link spam in the comments close to a time stamp link, don’t click it. I know some of u guys are probs old so uh just wanted to watch out for u

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Thanks, I always remove such links when I see them.

  • @njsongwriter
    @njsongwriter 3 роки тому +1

    I just installed one of these a few days ago.
    Instead of just replacing two old switches I also moved the switch location by connecting #14 3wire w/ground. Black wire taking power to the new switch and red and white wires bringing power back to the old switch location and connecting power to the light and the fan. (I painted the ends of the white wire black with a permanent magic marker.)

    • @kenbrown2808
      @kenbrown2808 3 роки тому +1

      by code, you're no longer allowed to do that, because of the requirement for a neutral in the switch box. also, while it is allowable yo use a white wire for a hot conductor under certain circumstances, it is not permitted to use it for a switched conductor.

    • @njsongwriter
      @njsongwriter 3 роки тому

      @@kenbrown2808
      So what exactly would I connect a neutral to in the switch box when the only thing in the SWITCH box is the switch. There is no terminal on the switch to connect a neutral to... Makes no sense!
      Anyway this home was built to manufactured home requirements as they were in 1996.
      If you're not allowed to use a white wire for a switch conductor are you saying that the three wire w/ground needed to have black, red and some other color than white which wouldn't have been any different in reality but would have likely cost more money. (Do they even sell that?)

    • @njsongwriter
      @njsongwriter 3 роки тому

      @@kenbrown2808
      Okay so what I should have done was bought 4-wire w/ground and simply capped off the neutral in the switch box (to meet most current code). Ugh. Guess I'll just pretend that this was done before 2011 when the old rule was still in effect. 😉
      The switch box is in a location where no one should ever need to (or want to) tap onto it to install a receptacle or anything else. The switches in it simply operate a ceiling light and exhaust fan in the M bath. There is a double duplex receptacle at the vanity. But if someone wanted to then they could replace the 3 wire w/ground with a 4 wire w/ground without too much trouble but it would be easier to tap off an outlet in the adjoining master bedroom which is still the same circuit.
      m.ua-cam.com/video/pnlHCiRN_RU/v-deo.html

    • @kenbrown2808
      @kenbrown2808 3 роки тому

      @@njsongwriter it is so that when you decide to replace the stack switch with a dimmer for the light and a digital timer for the fan, there will be a neutral to connect the timer to. and the reason for having the white either hot or neutral but not switched is so nobody in the future mistakes it for a neutral because the switch is off, and connects it to the neutrals.

  • @keytothegate68
    @keytothegate68 8 місяців тому +2

    Can you do this split ( with new pigtails) if you have only a hot and neutral going to the switch?

  • @Pallidus_Rider
    @Pallidus_Rider 3 роки тому +1

    Would be nice to have link to Instagram account on your About section.
    That way you can share photos of work, tools, etc. 👍

  • @IsshmanGarcia
    @IsshmanGarcia 3 роки тому

    @Sparky Channel Could you please do a practical demo of multiwire circuits and dangers of lifting the neutral wire, as it applies to Residential receptacles.

  • @xelaju8
    @xelaju8 3 роки тому +1

    Sparky is the best. Thank you. I love this channel.

  • @colinstu
    @colinstu 3 роки тому +1

    ouch, a pushmatic panel. that needs to go!

  • @johnham7422
    @johnham7422 Рік тому

    Hello sparky.,thank you for great video , I learned lot of information from your video. Do you have a video for two single pole switches with GFCI, if you have a video could you please share with me . Thank you

  • @Jann-IanHouston-Graham
    @Jann-IanHouston-Graham Рік тому

    Hi Sparky,
    Your video on replacing the double switch ("Double Switch Test and Replacement for Bath Fan and Light in a 1960 House") was helpful, but I have encountered a problem that I hope you (or someone) can advise me on.
    My mother has an old double switch that controls two lights (one on each switch). One side of the old switch stopped working (it controlled a light in the bathroom), while the other side continued to work (it controlled a light in the laundry room). I replaced the switch, but I can't quite get it to operate the two lights entirely separately. The bathroom light is fine. I can turn the switch that controls the light there on and off and the bathroom lights go on and off. Great. However, the second switch, which is supposed to control the light in the laundry room, only works when I have the bathroom light on (i.e., the switch for it is on). If I have the switch for the bathroom light off, the switch that controls the laundry room light doesn't do anything. The laundry room light remains off. When I turn on the bathroom light (using the adjacent switch), the switch for the laundry room light turns the laundry room light on an off. I'm puzzled. At first I thought that the switch might be faulty, but I've now tried 3 switches and each time I had the same result. I've changed around the wiring, but that has only made things worse.
    There are two cables coming into the box. The one that controls the bathroom light has power (one black wire as well as a white wire that I have attached to the opposite side of the switch). There is no power in the other cable, which runs to the laundry room light. I currently have the black hot wire fastened to a black screw on one side of the switch and the white wire from that cable, as well as the black wire from the 2nd cable fastened to the brass screws on the other side of the switch. I realize that no one may respond, but I am hoping to figure out what I need to do to correct the arrangement (my Mom says she's OK with having to turn on the bathroom light in order to use the switch for the laundry room, but some Moms will forgive anything!).
    Cheers, Ian

  • @illestofdemall13
    @illestofdemall13 3 роки тому +1

    In this video, you said that you can recognize that the older original wire is for the light, and the newer add on is the fan. Another easy way for someone to recognize each load on a double switch is to take note ahead of time of the orientation before removing the old wires. In this case, the top switch is the light and the bottom is the fan.

  • @mikeherndon1281
    @mikeherndon1281 Рік тому

    Great video and I’m a novice at wiring. Question please. You said in the video that you connected the Neutral wires. Where did these come from seeing that the only Romex is to the fan? Again, I’m new to this, so may get some laughs from everyone!

  • @JD-ch1wo
    @JD-ch1wo Місяць тому

    What happened if I hooked it up like that and nothing worked?Its an old house and we added wire

  • @MAGSJok3r
    @MAGSJok3r 3 роки тому

    We installed this switch on a bathroom circuit downstreamed from a AF/GFCI - one switch controlling vanity lights plus shower lights, one controling 480 CFM fan. Switch grounded. Nice space saver. Great Video

  • @ccadama
    @ccadama 3 роки тому

    @Sparky Channel. Thank Bill for another educational video. Seeing old wiring with fabric insulation brings back memories to the home I grew up in that had it and I'm pretty sure all the circuits were run in conduit. If that's the case, does that make it easier to rewire back to the main panel? At least the fuse box was replaced with a circuit breaker panel.
    Hope you and your family stay safe and well.

    • @SparkyChannel
      @SparkyChannel  3 роки тому +1

      Yes, re-wiring is greatly simplified if the wires are in conduit. Thanks and you guys stay safe as well!

  • @Jeff-Lawrence
    @Jeff-Lawrence 3 роки тому

    Hi Bill from Sparky channel
    Great explanation
    What a mess inside that box, yuk
    Keep up the great work

  • @nickanthony90
    @nickanthony90 4 місяці тому

    Why does my double switch have 6 wires and yours has 3?

  • @tedlahm5740
    @tedlahm5740 3 роки тому

    Ground wire in a switch box, decades before required by NEC? Much prefer
    a window in a bathroom.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      I was surprised to see the ground wire there but I put a Wago on it to extend it because it was so short and hooked it up. :)

  • @CHCMATT1
    @CHCMATT1 3 роки тому

    This is super helpful Sparky! I am planning to do this soon, so I really appreciate these videos. Keep up the awesome content :)

  • @Deafjustin
    @Deafjustin 3 роки тому

    1960 house had two wires and no ground mean older house had clothes with wires.

  • @Lyrisik
    @Lyrisik 3 роки тому

    Thanks for the sub!!!! I've been binge watching ur vids and it was cool to get that notification from you.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      That's great! Thanks! No problem on the sub.

  • @GBGardnerBender
    @GBGardnerBender 3 роки тому

    How can I contact? I'd like to explore a possible partnership.

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Hi! I love your products! wpm44@yahoo.com

  • @josianrodriguez1249
    @josianrodriguez1249 3 роки тому

    SALUDOS SPARKY FROM CLIFTON N.J ANOTHER GREAT VIDEO. G.B.Y.

  • @warronfrench8163
    @warronfrench8163 3 роки тому

    Fantastic video as always Sparky. Your videos have reminded me and helped me to save tons of money on electricians fees.. Thank you.

  • @Lyrisik
    @Lyrisik 3 роки тому

    I've actually switched to Wago lever nuts after seeing them in ur video

  • @mugg1841
    @mugg1841 3 роки тому +1

    Do you have a video for a switch with a light on the other end so it lights when turned on?

    • @JasonW.
      @JasonW. 3 роки тому

      A pilot light switch is what you are looking for.
      Leviton 5628-2w or for more fun, 3 way version 5638-2w

    • @mugg1841
      @mugg1841 3 роки тому

      @@JasonW. I bought a Eaton light switch with a pilot light. Want to replace my attic light switch with that so I know when the lights are on from the switch. When I took down the current switch the white wires are twisted and capped with a wire nut. The black wires are on the switch. The new switch has 2 black screws on one side for “line” and the other side has one brass and one silver screw. Do I need to put a pigtail on the whites and attach it to the silver screw on the new switch? Trying to wire it properly thanks.

    • @JasonW.
      @JasonW. 3 роки тому

      @@mugg1841 Yes, add a pigtail to the white wires and attach to the silver screw on the switch. Edit: incoming line black wire goes to the black screw, and load black wire to the brass colored screw.
      And then be thankful the original installer brought power to the switch, then to the light, or you likely wouldn't have the white wires.

    • @JasonW.
      @JasonW. 3 роки тому

      @@mugg1841 You'll know if you have black wires on wrong screws, the pilot light will be on all the time.

    • @mugg1841
      @mugg1841 3 роки тому

      @@JasonW. thanks for the reply. I thought that’s what needed to be done but wanted to be sure before tapping into the whites to add to the switch.

  • @itsali654
    @itsali654 3 роки тому

    Why don’t we use this more often ? People like the individual switches more ? Or is it more expensive?

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Individual switches are preferable but sometimes there isn't enough room for a 2 gang box.

  • @aliso-pv7ll
    @aliso-pv7ll 3 роки тому

    Sparky, In passing I saw an Ideal product that is used instead of electrical tape to wrap around the duplex outlet. Now I cannot seem to locate the product name. Do you know about what I ask? Sparky, Thanks!

    • @SparkyChannel
      @SparkyChannel  3 роки тому

      Hi! Check out my video: IDEAL ArmourBand Insulating Wraps 47-100 ua-cam.com/video/ySQ6zgV_o1Q/v-deo.html
      The link for the product will be in the video description if you're interested.

    • @aliso-pv7ll
      @aliso-pv7ll 3 роки тому

      Sparky, thanks for the correct response. The ArmourBand was what I was looking for.

  • @jeffscomp
    @jeffscomp 3 роки тому

    I replaced one of those switches but it was for a bedroom ceiling light and a closet light. I didn’t know what wire went to what but after so many tries the closet light stayed off with the switch for it off and they both work the way they’re supposed to.

    • @SparkyChannel
      @SparkyChannel  3 роки тому +1

      Hi Jeff! Great to hear from you!

    • @jeffscomp
      @jeffscomp 3 роки тому

      @@SparkyChannel thanks Bill it’s good to hear from you too and watch your awesome videos. I hope everything is good. 🙂

  • @Sally-nd5pc
    @Sally-nd5pc 3 роки тому

    Hi,how can i contact you?

  • @maggiegonzalez7117
    @maggiegonzalez7117 3 місяці тому

    My landlord came and replaced mine. He couldn’t get the fan to work!!

    • @SparkyChannel
      @SparkyChannel  3 місяці тому

      Uh-oh.

    • @maggiegonzalez7117
      @maggiegonzalez7117 3 місяці тому

      @@SparkyChannelI’m going to try it myself because at first he couldn’t get the light to work then when he switched the wires he couldn’t get the fan to turn off!

  • @dakotbeastj
    @dakotbeastj 3 роки тому

    Pretty handy device!

  • @hilariohernandez340
    @hilariohernandez340 3 роки тому

    Hey sparky. Let me know if you can see my comment.

  • @konamanstudio2447
    @konamanstudio2447 3 роки тому

    😆🍻🍺😊

  • @jerryjohnson2421
    @jerryjohnson2421 10 місяців тому

    thank u cut the power ....the breaker boxx

  • @MrTooTechnical
    @MrTooTechnical 3 роки тому

    great

  • @blohnnie7395
    @blohnnie7395 3 роки тому

    Very simple explanation. Learned a lot.

  • @mathman0101
    @mathman0101 3 роки тому

    Hope you and your family are well Bill. When you get an old 1960s house with it’s no ground wire would you always recommend to the homeowner that grounds are run to all switches receptacles or better still re-wire the house which might be easier.
    I suppose when cost is an issue all you can do is at a minimum make it as safe as possible.

    • @kenbrown2808
      @kenbrown2808 3 роки тому +1

      that is always a difficult question. optimally, you would do a full rewire, to being everything up to current standards, less because of the lack of grounding than because the wire is old, and because modern living uses a lot more electricity than the 60s.
      the next best would be to protect every general use circuit (code calls it general lighting) and specific purpose receptacle circuit with a dual function arc fault/ground fault circuit breaker - and if the panel board is not new enough for those breakers, (I'm looking at you Zinsco, Federal Pacific and Pushmatic) then you should upgrade the panelboard, anyway, because the breakers are functionally obsolete. they only trip from overheating, so a hard short (what electricians refer to as a bolted fault - the worst short you can get) the breaker will take extra time to open - leaving an opportunity for the short to start a fire.

    • @mathman0101
      @mathman0101 3 роки тому

      @@kenbrown2808 Thanks Ken I know in the UK it would have to be a full rewire and panel replacement. Just wondering if a customer/client is old and doesn’t have the resources I guess you try to make it safe as possible, recommending rewire and panel upgrade but leave to the client to decide.

    • @kenbrown2808
      @kenbrown2808 3 роки тому

      @@mathman0101 there have been a few projects I've put my foot down and told them if they wanted me to fix it, it needed a full rewire. I've had a few where the customer couldn't afford the repair and I basically told them my conscience wouldn't allow me to leave the problem unfixed, even though they couldn't pay. on the good side, wire from the 60s, here is usually still reasonably sound, and wood frame houses usually need refurbished before the wiring gets dangerously bad.

    • @mathman0101
      @mathman0101 3 роки тому

      @@kenbrown2808 god bless you for doing the right thing and helping those in need.

    • @kenbrown2808
      @kenbrown2808 3 роки тому

      @@mathman0101 as a local bumper sticker says, "we're all going to die, and we know it. you'd think we'd be nicer to each other"

  • @marlonhernandez8411
    @marlonhernandez8411 3 місяці тому +1

    3:58 you don't need to turn it off, I changed mine live