Progressive Addition Lens (Part IV) - How to Troubleshoot a Progressive Addition Lens

Поділитися
Вставка
  • Опубліковано 5 лют 2025
  • In this video, we go through the troubleshoot commonly faced while dispensing a progressive addition lens, What are the causes behind them and how to solve it systematically.

КОМЕНТАРІ • 41

  • @kaminikhadse7376
    @kaminikhadse7376 7 місяців тому

    Very Very well explanation by you sir ji good practical examples

  • @MrAmeerpt
    @MrAmeerpt 5 місяців тому

    All videos are excellent. Is it good slight over correction of ADD power in progressive?

  • @wcdwiw
    @wcdwiw 3 роки тому +1

    Very informative and useful. I am to get my progressive next week.

  • @RahulKumar-ve9ys
    @RahulKumar-ve9ys 4 роки тому +2

    Let’s make it simple..!!!
    great work, keep going up 👍👍👍

  • @ravisarangsahu2073
    @ravisarangsahu2073 8 місяців тому +1

    Good information

  • @janakadasanayaka4701
    @janakadasanayaka4701 Рік тому

    Wow it’s really help me a lot ,, thanks a lot , could you explain me this trouble also ,, when customers look at the image like phone or book they see some angle not actually image ,, thanks

  • @krishnachaitanya1511
    @krishnachaitanya1511 Місяць тому

    Will the unwanted cylinder in belended zone increase with the increase in cylinders in distance or it will be the same as plano /add lenses design

  • @zebasiddiqui1722
    @zebasiddiqui1722 4 роки тому +2

    Very well explained sir 👍

  • @sarojkhushboo588
    @sarojkhushboo588 4 роки тому +1

    Nice explanation 👌
    Very helpful video sir 👍

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  4 роки тому +1

      Thank you for your compliment keep watching more videos to come

  • @arindommaji1921
    @arindommaji1921 4 роки тому +2

    Best explain 🙏

  • @ganrajhake7827
    @ganrajhake7827 4 роки тому

    Sir your explanation is best ..thanks for this session..it's very useful

  • @nanik9690
    @nanik9690 Рік тому

    Sir small doubt if thd patient is using shell frame how can we adjust the nose pads area ... Means need to do frame up or down based on the patient complain on these conditions
    Can we do pantoscopic tilt or temple adjustment for better results..?

  • @navyaj94
    @navyaj94 2 роки тому

    PD can be corrected by wrap angle??

  • @amitkumarsingh7546
    @amitkumarsingh7546 3 роки тому

    very informative talk.

  • @thukkaiappankarki1701
    @thukkaiappankarki1701 3 роки тому +1

    Please give me some idea to how to calculate the corrider size prior to order the lenses ...

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  3 роки тому +1

      When you calculate the corridor size simply measure from pupilary center marking to the lower rim
      Now ideally I would say go for short corridor that is 16 mm that has lesser problem because as you take ultra short like 14 then the peripheral aberrations ar more

    • @thukkaiappankarki1701
      @thukkaiappankarki1701 3 роки тому

      As u said this corrider size as 16 mm is suitable for all design ?..thank u so much for ur reply sir

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  3 роки тому

      Mostly but it would change in some cases like depending on B size for frame but till now in my practice I found 16 as the most suitable

  • @navyaj94
    @navyaj94 2 роки тому

    What if CX selected shell frame without nose pad??

  • @thukkaiappankarki1701
    @thukkaiappankarki1701 3 роки тому +1

    Bro...pls do one vedio for complete refraction for the patient...

  • @endersgame7277
    @endersgame7277 4 роки тому

    can we change faceform to correct pd? how does face form affect the vision of our patient in progressive lenses

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  4 роки тому

      By changing face form it will it will result in tilt induced power and it won't help much in case where pd is more in or out

  • @akandondaelly6205
    @akandondaelly6205 2 роки тому

    This is good clap

  • @indrajitpaul2931
    @indrajitpaul2931 3 роки тому

    If someone following curve object in near vision then what would be the possible cause?

  • @shahebazsheikh424
    @shahebazsheikh424 4 роки тому +2

    👍👍

  • @amitkumarsingh7546
    @amitkumarsingh7546 3 роки тому

    one problem I have faced that my patient's PGP was -5.57/-2.00 *20(6/9) & -5.57/-2.00*180 (6/6p).New RX : -7.0/-1.75*05(6/6) &-7.00/-1.25*180(6/6) add.+1.25DS(N6), 1st time user. Now patient used to up his chin to see distance, intermediate & near as well.What is the problem ? Did I overcorrected?or his fiitting height is too small? remedy plz?

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  3 роки тому +1

      I would recommend check the centeration first also check the refraction once just to rule out overcorrection as I see old prescription was 5.75-2 and patient was 6/6p so how come almost 1.25 D change
      The idea of troubleshooting is recheck all your step in a sequence n see where is it wrong and correct that part
      Hope it helps

  • @Sunnyprashar921
    @Sunnyprashar921 3 роки тому +1

    Hello Sir,, agar aap hindi mai video banaya to hame achhe se samajh ayegi,, mai or mere jaise bhaiyo ko English achhe se nahi aati,, sir aap se 🙏request hai

    • @Sunnyprashar921
      @Sunnyprashar921 3 роки тому

      Sir,, aap ke English ke bani hui videos hame samjhe nahi aati

    • @OPTOMETRYWITHTARIK
      @OPTOMETRYWITHTARIK  3 роки тому

      Jo bhi videos banayi gayi hai unke hindi version apko hindi videos namak playlist mein mil jayengay ye video bhi hindi mein available hai link ye raha
      ua-cam.com/video/XH0zVLJRrZQ/v-deo.html

  • @ajitkumar-fe6ko
    @ajitkumar-fe6ko 3 роки тому

    CAN YOU PROVIDE YOUR LECTURE IN A PENDRIVE