You may expend even more than 20 but you have to provide down beam. Whereas if your column span is minimum 18 feet you may apply hidden beam for resisting above load.
the beam size and steel spec changes according to the design there is no thumb rule for beam size and steel req. also the span affects the depth of the beam
I having a existing home 10x45=450 sqft single story. I want to construct one more floor. But there's no any existing column in ground floor. What should I do; either make new column in ground floor or not ?
What be the reinforcement(bar) for each column, for residential building G+2 story, each floor area 34*26(920) sft approx. Which size of column be best as per your opinion. SBC is very good of our area.
Till 3 floor reinforcement details. Column Size should b minimum 9×12 and maximum 12×15. Vertical we should place 4 bar of 16 mm and 2 supported bar of Dia 12 mm. Ring should b 8mm Dia. Spacing between two ring should b 150mm to 200 mm. Hook length of ring should b 10 D. Hook should b bend in 135 degree. Bar should be cut in such a manner that lapping will be at L/2. Concrete grade should b 1:1.5:3 but you want to get good workability along with strength use 1:2:3 Ratio of concrete. Use opc cement for rcc work. Use secondary steel bar for cutting material cost.
As per IS 13920 colunm size 9" not allowed. Minimum size 12". Misguiding wrong video. you should need to learn structural design before uploading wrong information.
Nice details bro.. i m software developer but getting point very well... i have self design my house plan.
Super design
Sir Beam placing kase karte hai please video banaye
Bhayya me bahut dino se dekh raha hu videos,column kaisa rakhna he , aur dival ka uper column banana ye jaruri hai kya bathaiye
Sir 3d modelling ke liye best software konsa ge
3ds Studio Max
And
SketchUp Pro
Revit
Floor planner
AutoCAD
For 4flour construction details of same please
thanks
Best expln by brilliant strl engr bhushan ji
Can we expand span between column above 15ft by using flat beams. If so how much and what are the specifications for beams
You may expend even more than 20 but you have to provide down beam. Whereas if your column span is minimum 18 feet you may apply hidden beam for resisting above load.
J
the beam size and steel spec changes according to the design there is no thumb rule for beam size and steel req.
also the span affects the depth of the beam
Column vertical ya horizontal position lena o batao sir
Very good information
I having a existing home 10x45=450 sqft single story. I want to construct one more floor. But there's no any existing column in ground floor. What should I do; either make new column in ground floor or not ?
You can construct by adding column from ground floor, or construct wall over existing wall , so that load will transfer through the wall to ground
Good expln acha batayiye baiya
What be the reinforcement(bar) for each column, for residential building G+2 story, each floor area 34*26(920) sft approx.
Which size of column be best as per your opinion. SBC is very good of our area.
Tatadurashine roof top ki liye colomn strength kiya hoga please bataye.
What about partition wall for bathrooms... Is there no beam underneath it??
Plinth beam is there
Plinth beam is there
Thankyou so much 👏
Is it for 2 storey or 1 storey
Sir Beam placing in plan kase karte hai please video banaye
Sir
How to fix beam size & depth including bars
It's very confusing to me
Please help me sir
Please make a video on beam position on this plan.... ❤❤
Thank you
Very good sir👏
Sir 40*55 k ghrr plan mai kitni colum or beam aana chahiye..
Very good
Bhai ye zroori h ki ik line honi chahiye colum m
Which is this application u used for 3D plan?
Sir bas ye bta do 3floors ke liye ye reinforcement kafi h kya
Till 3 floor reinforcement details.
Column Size should b minimum 9×12 and maximum 12×15.
Vertical we should place 4 bar of 16 mm and 2 supported bar of Dia 12 mm.
Ring should b 8mm Dia.
Spacing between two ring should b 150mm to 200 mm.
Hook length of ring should b 10 D.
Hook should b bend in 135 degree.
Bar should be cut in such a manner that lapping will be at L/2.
Concrete grade should b 1:1.5:3 but you want to get good workability along with strength use 1:2:3 Ratio of concrete.
Use opc cement for rcc work.
Use secondary steel bar for cutting material cost.
Thank-you sir
Keep watching
Thank u sir...
Ak video slab beam par bi banao.... please
Beam ka top bar 10 mm???
So amazing
Minimum size 12mm
Misguiding vedeo do not follow.
Boss any software regarding cad which works in mobile
Sir ji coloumn horizontal rake kisi vertical rahke
Pillar 9"/9" or slab 4" to 4.5" usme mai bar 12mm, lod maximum hoga.4.5" slab main bar 10 mm is not ok?
Sir
Ekhe ghar ka map ( room sizes & columns, beams)
Kaise fixe karthe he ekh jaagha pe
Please kindly help me sir
Plan save kese kre. ?
Sir..Stairs par support ke liye 1 column diya he..Only first flight par..Will it be ok..
0k
G+2 ka colum size kya hona chahiye and beam size kya hona chahiye agar room uska andar 2 room 18feet long 12feet width rahega to kese karna padega
Map ka exp kya hoga kaise aap se mile
email id hai contact kare
Tq so much
Thanks a lot sir
Pooja room ka slab beam to bahar kharab dikhega 4' wall ke kinaare
9/12 column mai 6 12mm rod diya hai. Base 5/5/5 hai.. 14 pillar in 1050 area. Kitne manjil bana sakte hai ispe ?
G+2.
Good information sir
Sir flyover se related vdo banaiye plz Sir
I will
@@Civiconcepts
Thank-you sir mai flyover me Abhi kaam karane aya hu but mujhe jyada jankari nahi hai
@@Civiconcepts
Mujhe aap ki aur aap ke vdo se help chahiye
Sir agr size jyada ho living room ya bedroom ka to kitne ka column bnaaye
Till ground floor 9×9
Very informative.
Misguiding wrong video.
Thanks sir
Sir u r video's so helpful to me in site
Super explaining & clarifying
20by 20 qualms position and beem please
Bhai ye jo r c c book ap k sat hai ya jos page pr r c c design hia hai wo book ap email kr skte hai
yes sir email me
Sir इस तरह हम कितने मंजिल ले जा सकते हैं , 3 मंजिल जा सकता है क्या
18y 19 ka hole ka colam size
47x24 House plan bhej o
Book name
I was thinking why can't he use red colour to show columns, then he suddenly changed his marker to red colour. So ossom.
Kitne bathroom hai kitne kitchen aur toilet kitne hain vah sab likhkar bataen Karen
2×40
क्या इसमे एक कलम से दूसरे कॉलम के लिये बीम देना जरूरी है
Very important.
sir you may kindly clearlly teach
Nice video, but one problem u repeted one sentence 4 to 5 times, it is waste of time
👌💯 mobile apps 3D house map banane ka achcha app kaun sa hai
You are using stirrups bars on slab 🙅♂️
As per IS 13920 colunm size 9" not allowed. Minimum size 12". Misguiding wrong video. you should need to learn structural design before uploading wrong information.
shotte structure mein chl jata hai
masons chla dete hai
Woh suggest kiye hain 9×12
Bhai to tu video bna kr right information dede comments kr chale jana aasan h
LIKE
👍#
I didn’t understand a word he said😭
You can see now how rebellion towards God hurts life. It brings confusion between the people.
Nonsense video. Can some one design colum without engineering logic? Becaise you gave the gyam?
Bhai video ka title kya hai aur tum video me bata kis chiz ko re ho
अपना नम्बर भेज दो
Thank you
Thankyou sir
Thank you sir