Thanks zahid, but one extra coil is also connected on the top of both coil named RL1 in this type ABB VD4 breaker. Tommorow i will take photo then explaine.
Ni. Coil supply Kabhi bhi continue ni jayegi .. Jb bhi fault ya command relay se aayega to Master trip ki pulse continue jayegi or Master trip breaker ke coil ko bus ek pulse dega... Jb tak relay reset ni hoga tab tk mastrip bhi reset ni hoga.
Abb breaker Mai spring charge hone ke baad bhi spring ka contact close nhi ho rha hai,issue Mera breaker close nhi ho pa rha hai,Kya kroo please bataye
Thanks friend
You are welcome❤
Very neat and simple explanation. Similarly please share the video of replacing of spring charging motor
Thank youMr. Raja,Sure ! soon i will make a video
Very useful for electrical engineers
Thank you sir
You are welcome bro !!
Very Helpful video Sir....
Thank you...
Thank you dear
Want More videos from You.. great Job
Yeah sure...
Nice explanation 😊😊😊very useful
Thank you for your comment
Very helpful video zahid Hussain sir
Sir please ,provides vd4 indoor ki drawing with relay wiring
Yeah sure...please share your mail id
Thank you for your valuable comments
Hi i am sonjoy
From Bangladesh
Your video good
Thank you dear
Informative, thanks for sharing.
Thank you
Can you share a video for same breaker's bush replacement (plastic part)
Thanks मित्र 👍
i really like your attitude
o bhai,,,,,, thank you yaar
Thank you so much. Very helpful
Thank you for your valuable comment
Excellent sir thank you
Thank you dear...
Sir same ABB ka outdoor breaker hai jo ki remotely our manually close nahi ho raha hai. Mechanically close hota hai. Kya problem ho Sakta hai.
Good job. Possible to upload How to replace -AU unit (contactor assembly feeder)
Thank you dear
Very nice 👌 sir
Thank you dear
Great Effort Bro..
Thank you bro
Nice sir vidio
Thank you Mr Kumar
Nice explanation..!
Thank you bro
Thanks zahid, but one extra coil is also connected on the top of both coil named RL1 in this type ABB VD4 breaker. Tommorow i will take photo then explaine.
Yea, you are right ,
1- close coil
2-open, shunt, trip,off
3- Undervoltage
Yes three types coil also use in L&T Breaker
Pls tell me, agar CB me tripping coil Or closing coil fail hota hai to kya krna Chahiye , Ye mereko interview me question kiya tha
Immediate Replacement
Nice video
Thanks
Simply Nice...
Thank you
How much value hona sir ....for its perfect working ke liye....
Depends on coil
Excellent g
Thanks G
Sir plzz explained this video with closing and tripping of abb drawing
Sure dear
Sir what are u pulling out at the 3:04
VCB ki coils nikali thi maine...
Why are you Testing the resistance at the 4:03?
Thanks and make vedio how to measure HT and LT Breakers Contact resistance and what is Max and Min value of Contact resistance🙂🙂
Sure, Bro
this good but how system magnet coil open & repairing please tutorial video
Thank you , its so simple, you can remove one screw and all coil in your hand
Thanks sir 👍
Most welcome
I am new , how to easily learn and maintenance of the Abb 11kv sf6 mv please tell me if you have time
you can learn from youtube
But closing and tripping circuit ki windings resistance 150 se 225 ohm tak hota hai sir
Depends on coil ratings
Sir vcb ki control wiering ko kaise check kare diagram dwara 🙏
You can go with ferul number...
Sir, kiya tripping aur closing coil ka supply continue jaiye gi ya ek bar jakr fir off ho jaiye gi. Pls ans me.
Ni. Coil supply Kabhi bhi continue ni jayegi .. Jb bhi fault ya command relay se aayega to Master trip ki pulse continue jayegi or Master trip breaker ke coil ko bus ek pulse dega... Jb tak relay reset ni hoga tab tk mastrip bhi reset ni hoga.
@@ZahidHussain-wk1zl sukria sir,,, master trip kiya L.T Line ke acb mai v hota hai.
साहेब बाडी आथ व बिटवीन अथ 5000v. मेगरने किती.पाहीजे
5KV are enough
❤️
GOOD
Sir by mistake the ON OFF button got broken due to manual handle, how to repair this
Please share site details, we will send team, amcsupport@aepl.co
Nice
Thank you dear
Make a ABB ht motor feeder pm
Sure
Ok
pls guide me sparing charging continue charge ho raha hai hold nahi ho raha hai kya kare
Spring charge motor cutoff limit switch damage ya misplace Hui hogi
Please share status of your issues
Thank you
Thanks to you
Sir, please plug me jo pin ha uski working & function explain kariye
Sure
Sir please a complet controlling circuit of vcb. Or acb
Sure, As soon as possible
Abb breaker Mai spring charge hone ke baad bhi spring ka contact close nhi ho rha hai,issue Mera breaker close nhi ho pa rha hai,Kya kroo please bataye
Check Close coil healthiness, Check proper supply voltage reaches to the Close coil ...
Trip coil ok tnc operat coil get DC but feeder not trip remotely or manually for abb breaker
Check trip coil strikker, listen coil sounds and adjust gap
Sir I need wiring diagram of cv mechanical life
Thanks
Thank you
شكر لك من فضلك هل يمكن شرح بالعربية او الفرنسية
Allah Kareem
Sir actually...spring is charged but on or off is not working..
Vcb is not in home position, check either it on test mode or in service
Nice sir
Thank you
Sir video very nice but pic clin please
Thank you, we will definitely improve our quality.
Ye dono coil tripping vali he......closing coil uper lgi hui he
Coil same he hoti h but location ke hisaab se trip close bolte h
Brekar close karne par trip ho raha what problam
In acb or Vcb ?
@@ZahidHussain-wk1zl vcb
Yg bahasa indonesia ada tidak?
No, that is Hindi
Induction motor ka overhauling ka video upload kijiye sir
Ji, Zarur
Is breaker me mai kam kiya hu sir
Great
camera quality very poor
487
Video is not clear sir
Yeah... We also noticed, we are improving our video quality.
Thank you for your point.
100% boro teacher ko nehi pata
Video name is in English then the video is in hindi!!!
I am so sorry brother,
Please share your requirement or Problem. We will definitely try to help you...
zahid.hussain44@gmail.com