Delta DPS-150TB repair

Поділитися
Вставка
  • Опубліковано 19 лис 2024

КОМЕНТАРІ • 8

  • @coloradowilderness3139
    @coloradowilderness3139 Рік тому

    Always wait for your excellent troubleshooting for PSU.
    Thanks

  • @orlypalomar
    @orlypalomar 21 день тому

    Thanks for the video. Have the same PSU for a HP Microserver N40L... it's dead. The chip you replaced seems good on mine (0.5V on the diode test). There's also 340V across the bulk cap so I think the HV primary is ok. None of the transistors appear to be shorted. The DC outputs aren't shorted either. I haven't figured out what is wrong with it. Btw, is the green wire the power good signal? Doesl jumping it to ground turn on the PSU?

    • @electronicshaverightstolive
      @electronicshaverightstolive  20 днів тому

      @@orlypalomar green wire is PS on wire. Jumping it to the ground should turn on the PS. If not check capacitors. They may be the reason.

  • @matrixcrew
    @matrixcrew 8 місяців тому

    This power supply (Delta DPS-150TB) is used in a HP ProLiant MicroServer N40L. These MicroServers are used as a home/office NAS.
    The power supply in my server has just failed. So it might be a similar fix to get mine going again.

  • @kaml966
    @kaml966 8 місяців тому

    My power supply was also damaged.
    IC901(TNY268P) seems to be fine, but I will replace it to be sure.
    In my case, the R902 resistor was damaged (burned). Does anyone know what resistance it should have?