Це відео не доступне.
Перепрошуємо.
DIY'ers WATCH THIS - Easy Solution for Overheating 5kw Grid Tie Solar Inverter
Вставка
- Опубліковано 28 кві 2021
- 5KW Solar Inverter Overheating and shutting down Problem.
I just want to share on this Video my experience with my 5KW do it yourself grid tie setup with my 5 KW solis inverter model: SOLIS-1P5K-4G.
My Inverter Overheats and Shuts down. For DIY'ers, watch this video before you start your project to avoid same mistake that I make and Incase you encounter the same problem watch how I solved the problem.
If you like my video Please:
SUBSCRIBE, LIKE & SHARE and DON'T FORGET to turn ON the Notification Bell.
The 6kw version has the same thermal threshold where it will throttle back. I get about 5mins at 6kw then it will throttle back. I can see it because I have monitors on each panel so I can see what it being generated vs what is getting inverted. I installed AC Infinity fan and controller to keep it from going beyond 50c. Now it’s performing as it should.
Chief Thank for Info balak ko Din Mag DIY marami akong natotonan Sa Vedeo mo sa Barko Nag Trabaho.
Salamat
Pagkanindot kaau s emuhang vedio sir masabtan ug masundan jud sa mga baguhan ba.. Gbu sir,, tca
Hello sir. New follower mo po ako. Thank you for this tutorial. Keep it up and godbless po.
Very helpful. Salamat po
Thanks for sharing...
Maraming kau Mtutulongan sa idea na yan sit..👍👍👍👍👍
You're welcome at salamat din sa pag appreciate ng video...
Nice bro,keep it up we will support you just continue your content..
Your simple words Bro, really inspires me... thanks for your support... and keep your positivity to other people... Mabuhay ka...
Very informative video content
Glad you think so! thank you
Salamat Sir sa npakainformative na video! More solar video pa po sana 😊
Sir pwede po malaman ano po pinangedit nyo ng video? Ang galing e 👏👏👏
Thank you Sir... mix ang ginamit ko na pang edit, adobe photoshop at adobe after effects.
Salamat sir for additional knowledge. Tanong ko lang kung saan nyo nabili ang fan, thermostat at ibang materials. Tanong ko rin kung saan gawa ang inverter at solar panel mo. Salamat po. Stay safe and god bless.
ang thermostat at fan sa Lazada or Shopee ko lang nabili, ang panel at inverter made in china sa One Point System ko nabili.
Salamat kaayo ug dako sir. Actually duna sad koy 3.3kw sa Philergy Germany, with net metering. Balak kong gawing 4.8kw ang solar dahil sabi ng Philergy allowed daw ng 20% higher ng inverter ko which is 4kw. Kaya gusto nakong lagyan din ng controlled fan gaya sayo.
Yan talaga ang maganda Sir, na palagi ma maintain na mababa ang temperature ng inverter para tumagal.
Sir, good day po. Baka may na share ka regarding pros and cons sa Solis 5kw Hybrid or Deye 5kw Hybrid inverter. Salamat po.
Sir, Ano magandang single phase inverter? Solis or sunways? Ived read mas maganda heat dissipation ng sunways? Thank you.
Sir...ung set-up 1hp na submersible pump, ask ko lng kung ilang pane at battery ang kailangan. Thanks
Hello sir kung mag in power ko ug refrigerator lng mga pila kahay budget ana? Inverter ang reff namo
Sir, inig 5pm onwards ang voltage sa panel mo ubos mn siya noh, imo na e off solis inverter? Or automatic ra siya mo detect na if lower na ang voltage supply sa panel ig gabie e cut off ra niya automatically ang supply sa solar panel?
Subscriber here, please share the link where to buy thermostat
Idol kabaro how much ung set up mo yan??? Tgaks god bless po
thanks for sharing sir anu palaga gamit nyu sa pag edit sir yung ganyan set up animation
Your welcome Sir, Pang Edit ko ay Adobe Photoshop and Adobe After Effects 2020
Ginawa ko rin po yung cooling system using STC-1000 sa grid tie inverter. Pinadaan ko sya sa RCBO. Kapag nagturnoff na yung thermostat ay nag tri trip yung RCBO. Kapag XH-W3001 na temp controller ang ginamit ko ay di naman nag tri trip yumg RCBO. What is the reason po?
Sir pwd ba solis kahit minsan low voltage ang grid 210 volts po tia
Sir ung wire ng sensor, pwedi pong magkadikit? Dalawa po kc ung terminal. Salamat po
Sir most of the grid tie inverter may come which fault
at what temperature does your inverter start to cut/trip power?
60 degC...
Sir good day Asa ta ka Palit ug mga materyales ana .. gosto unta nga magtaud sa amoa balay.. thnk you sir
naa ray mga tindahan sa cebu sir... or sa mga online store...
link where u buy sir
Hello po sir salamat po sa video mo sir ... mwron po sana ko tanong ...baket po kaya yung sakin hindi nag add yung watts... example po yung isang string pv1 na may 2500 watts panel 1800 ang nacosume. Ganun din sa isang string pv2... dapat po +-3200 watts po yung total ...pero sa inverter po n solis +-800 lng yung na lalabas nya
Jhamz hindi ko masyadong na gets, 5kw total ng panel mo? (2.5kw+2.5Kw). then ask ko lang ilang yung total harvest mo daily?
Sir, baka pede yung view ng wifi monitor sa Solis. May grid vs energy monitor ba sya? Salamat
Yung sa apps nila meron yata Sir Ram... Actually hindi kasi ako gumagamit ng wifi monitoring apps, personal reason ko lang. isip ko lang baka kasi pweding ma hack ang setup ng inverter, kapag may mga hacker na walang magawa hehehe... sa akin lang naman yun :-)
Set-up ko naman timer lang na MCB din rail maliit lang naman ang konsumo ng fan kaya naka-on na lang siya the whole day tapos auto-off sa gabi.
Very informative Sir. Ask ko Lang baka pwede makuha Yung link sa Lazada at shopee Ng mga items. Thank you and God Bless.
i search mo nalang Sir marami naman mga supplier sa Lazada at Shopee. Check mo lang ang review ngproduct at ng store at para compare mo na rin ang mga prices para makapili ka.
Ilang watts solar panel mo sir?
English please.
I have 10kw system and interested in your videos.
English subtitles are available for this video and they're actually good.
Anyway, his presentation is clear enough that can be followed without speaking the language.
Basically, he used his 220VAC home supply to power both the STC-1000 thermostat-controller and the fan (which was 220VAC as well).
The wiring schematics couldn't be clearer, just take a screenshot or pause the video at 6:20
Lines in parallel and neutrals in parallel, probe goes to 3 and 4.
As for the fan, if you want to use several instead of just the one, buy a bunch of 220VAC fans and connect them all in parallel, making sure that their combined amperage requirement is below 10 amps.
Sir new subcriber po , , tanong lng po, grid tie pala hndi xia gagana sa gabi? Tama po sir? Kung ganon po wala tayong ilaw sa gabi ? , nalito lng ako sir pasinxia na,
Yes ang grid tie ay gagana lang sya sa daytime, pero dahil naka tie siya sa grid or connected din sya sa supply ng electric company, kung wala ng araw or even makulimlim ang panahon na mahina ang harvest ng solar, tinutulungan ito ng kuryente galing sa grid at sa gabi na wala na talagang harvest, yung kuryente na na galing sa grid ang fully mag su supply sa bahay so continous pa rin ang kuryente.
Hello po..tumatanggap po kau ng kontrata to Batangas city
Dis a ka ka palit anang Solis inverter sir?
Sa Cebu Lang sir sa ONE POINT SYSTEM...
3kw Solis inverter po ung gamit ko sir
Magandang araw po sir.posible po kya n ganyan ung kaso ko sir.pag mainit po kc ang panahon tapos binuksan ko ung aircon nag sisignal s’ya ng alarm tapos pag pinatay ko na po ung aircon nagiging normal na po ulit s’ya.salamat po sir
Posibli po, pero para malaman talaga kung ano ang alarm, kapag nag alarm tingnan niyo po kung anong nakasulat sa display like if over temperature OV-TEM ang nakasulat sa display, if over voltage naman OV-G-V01. sa akin kasi na experience ko yan noong bagong install ang setup ko, kapag mainit ang panahon nag over voltage siya at mag trip din.
24/7 naka on imo inverter o naka timer o manual imo i-off inig wala nay adlaw?
automatic mag off ang inverter kung wala nay harvest ang panel, then automatic nasad mag on igka buntag.
@@rodBACON Ilang months po bago ma approve yung net metering nyo from complete submission po ng docs?
Sir meron ako solis gridtie inverter 1000 watts. Ilang wattage po ba ng pv solar panel need ko para gumana ang inverter ko. Bumili ako kaso dina na demo sa akin. Pero nung ma installed ko na pagbukas ko sa dc switch dipo siya gumana. Tnx po
Sa manual ng inverter may nakasulat dyan kung ilan yung maximum power (watts) at maximum input current (Amps) ng MPPT ng inverter, dyan ka mag base. at meron din yang operating voltage range... hindi po gagana ang inverter kapag hindi maabot ng panel ang operating voltage na kailangan ng inverter.
@@rodBACON salamat po sir. New ako sa ongrid diy. Pero alam ko ang offgrid kaya di ako mahihiyang magtanung sa kahit sino.para hindi ako magkamali
Dc po ba yung fan?
No Sir Jan Dong AC Po 220V
Hi,Sir,,
Ang ako nga Deye 5kw,,naka Net Metering,,,Max Solar Power 6500 Watt 13 panel Trina nga tag 500 watts..
Ang akong pangotana Sir, pila ka watts ang safety Max Sell Power sa Grid..kay ng basa ko sa Manual wala man ge sulat sa Manual..
Salamat,,,maayong pag laweg sa kadgatan... 🙏🙏🙏
Wala may maximum limit sir, basta walay load ang imo inverter all harvested power ma export na to the Grid. Naa koy mga nabasa nag gina Limit daw sa DU ang ma export, like ginaprogram sa meter para ma limitahan ang export power, storya rapud rapod lagi wala joy ebidensya. As per sa akoa setup wala may problema sa export adn wala say limit or maximum.
@@rodBACON Sir,,,Daghang Salamat sa emong pag tubag kanako...in my vacant time sige ko og rewinding sa emong mga presentation Video.
More power to you,and your Family..
Salamat 🙏🙏🙏
Sir pwede po bang patulong sana po mabasa nyo ito yung solis 4G namin nag error ng OV-G-V01 patulong po thank you.
Grid overvoltage po yan, baguhin niyo yung setting huwag niyo ilagay sa Philippine standard, gawin niyo lang User Define at taasan niyo ng kunti ang setting ng OV-G-V1. Check niyo sa manual ng inverter paano gawin.
@@rodBACON may video po ba kayo paano gawin ito sir hindi ko po kase alam yung setting ng user define , patulong po
hmm I have 8KW 5G solis inverter...its 5.4 kw grid tie but it rarely reaches 5wk+
lot of factors that affects solar harvest, like panel efficiency, panel orientation and it's normal that you cannot get 100 % from panel. With my setup the maximum I observed is only 90% of the capacity.
@@rodBACON thank u sir nako dami pa ko tanong haha
Sir Ilan Ang average production Ng 5 kw grid tie set up ?
If i average ko ang monthly harvest, nasa around 22-23 kWH per day. Ang maximum ko na EXPORT in one month nasa 550kWH.
@@rodBACON salamat sa quick reply Sir! Tanong ko lang Sir Yung Solis 5 kw dalawa Ang rating nya isang max input Amp. 11/11 tapos Yung Isa 17.2/17.2 amps alin doon Ang dapat I consider sa pag pili Ng panel?
@@lipazon8430 ang 11amps kasi yan yung max usable input current per MPPT, ang 17.2 Amps kasi max. short circuit input current yan.
@@rodBACON ok Sir thanks!!! More power sayo 💪👌 and sa channel 👌
@@rodBACON bisag sa mga buwan na ting uwan, kaabot gihapon ug 20 kWH?
Sa akin electric fan naka tapat
Mahina clasi ang inverter mo sir subukan mo senergy
salamat sa feed back sir Marlowe... mag 3 years na ang inverter ko hanggang ngayon ok naman wala ng problema, noong una lang talaga pero after nalagyan ko ng cooling fan ok na sya still running... 27 months zero electric bill na ako...
Sir paano kung 24v may kailangan bang iset? at parehas din ba ang diagram?
Parehas lang din po ang diagram Pero dapat yung bilhin niyo na controller ay pang 24v din.
@@rodBACON may kailangan pa bang iset device para maging compatible sa 24v?