Interview Question on RCBO| RCCB vs RCBO| How to Read Rating of RCBO| Hindi

Поділитися
Вставка
  • Опубліковано 6 січ 2025

КОМЕНТАРІ • 39

  • @karmpatel4784
    @karmpatel4784 2 роки тому

    Great video Abhishek, keep up the good work. Cleared all doubts. Thank you.

  • @junemondal4011
    @junemondal4011 2 роки тому

    Single phase 3hp motor ka lia konsa appear and konsa mili am lagana chaia

  • @OMGCircle247
    @OMGCircle247 2 роки тому +1

    Sir, DTC vs Vector control in vfd par video bnaiye please basic difference atleast bta dijiye 🙏

  • @harshithaj2762
    @harshithaj2762 2 роки тому

    Excellent information about
    Rccb and Rcbo

  • @zahoorrehman6837
    @zahoorrehman6837 2 роки тому

    Sir, pleas, rolling mill k 600 kw DC motor ka load laite time RPM down hota hai. What is the reason.

  • @Technicalcobra
    @Technicalcobra 2 роки тому

    Sir,
    you explain with example of 30mA, and you say if leakage current cross the nominal ratting (30mA) then it will trip, in case of leakage current.
    But in this application maximum acceptable range is nominal ratting (in this case 30mA) as per industrial regulations.

  • @safvan1996
    @safvan1996 2 роки тому +2

    Hello Sir, Please IMCC BASIC KNOWLEDGE & IMCC WORK FUNCTION Related video banawo... Aaj ke jamane me Auto plant me IMCC jyada Use hota hai...

  • @mayanksoni8465
    @mayanksoni8465 2 роки тому

    Single pole main rcbo 10 Amp B Type milta hai ki nahin.

  • @booktubershivani3302
    @booktubershivani3302 2 роки тому

    Very helpful video keep uploading video sir

  • @rakesh_maurya_
    @rakesh_maurya_ 2 роки тому +1

    Sir,
    PMCC aur MCC pr ek video banaiye..please.

  • @jky6697
    @jky6697 2 роки тому

    Sir 7SJ600 relay me o/c and E/ c fault ki setting kaise check karte h please sir explain

  • @PrakashKumar-ug5tk
    @PrakashKumar-ug5tk 9 місяців тому

    Good knowledge sir

  • @rashmiranjandalai9054
    @rashmiranjandalai9054 2 роки тому

    B.D.V test kitna kv aana chahia, easka koi calculation he kya

  • @fahadmukhtar1124
    @fahadmukhtar1124 2 роки тому

    Abhishek Joshi bahi i need your advise , in an industry due to huge welding machines (inductive load) there is voltage fluctuation due to which solar inverter has synchronizing issues , please suggest how can we avoid this voltage fluctuation ?

  • @sefatullah441
    @sefatullah441 2 роки тому

    well done, keep it up

  • @akku_yt2987
    @akku_yt2987 2 роки тому

    Sir, video ache h bhot but mera ek alag doubt h agr hm kise motor ke winding ke continue live circuit me le to kya multi metre me kuch interlock hota h ya direct blast ho jayga

  • @ikfans707
    @ikfans707 2 роки тому

    From Pakistan
    Helpful topic

  • @arifpathan7787
    @arifpathan7787 2 роки тому

    Sirji, please change over scheme auto n manually pe ek video banaa dijiye 11kv / 0.433 kv pe plz sirji

  • @mayureshrana3504
    @mayureshrana3504 2 роки тому

    Sir IMCC Panel knowledge required to all industry

  • @manishyadav-bi2tf
    @manishyadav-bi2tf 2 роки тому

    Sir please make a video on regenerative braking of railways system

  • @arpitdhiman4021
    @arpitdhiman4021 2 роки тому

    Great video sir.

  • @ashoksharma-vu8nm
    @ashoksharma-vu8nm 2 роки тому

    Sir ek video live fault finding via load to panel testing.it will be very helpful.

  • @kashiftutorial9513
    @kashiftutorial9513 2 роки тому

    Sir distance relay ka Bata den please

  • @mayureshrana3504
    @mayureshrana3504 2 роки тому

    Please share some knowledge of Imcc panel

  • @nitindhangar8762
    @nitindhangar8762 2 роки тому

    Sir flote switch with timer ke sath drawing ka video banavo na

  • @anilsahooofficial8054
    @anilsahooofficial8054 2 роки тому

    Very informative

  • @maanrock2657
    @maanrock2657 2 роки тому

    Sir plz make video on Converter duty transformer

  • @jmelectrical13
    @jmelectrical13 2 роки тому

    अगर कहीं RCBO लगा हुआ है और वह बार-बार ट्रिप होता है तो कैसे पता करें कि अर्थ फॉल्ट से ट्रिप हो रहा है या शार्ट सर्किट की वजह से

  • @phoolsingh3658
    @phoolsingh3658 2 роки тому

    Excellent.

  • @ambalalnagda3282
    @ambalalnagda3282 2 роки тому

    Thanks 👍 sir

  • @sagarkumbar2173
    @sagarkumbar2173 2 роки тому

    Sir one video for rem 610 really

  • @amitbhimani6037
    @amitbhimani6037 2 роки тому

    Please make imcc related vidio

  • @prakashsharma0986
    @prakashsharma0986 2 роки тому

    Dangerous limit current for body is 200 MA not 30MA shriman

  • @madhuvanprajapati1722
    @madhuvanprajapati1722 2 роки тому +1

    sir not say that RCBO also provide short circuit protection.

    • @electricalwithabhishekjoshi
      @electricalwithabhishekjoshi  2 роки тому

      RCBO is a combination of MCB and RCCB. It provides all the protection provided by mcb and rccb.

  • @dipankarnath6324
    @dipankarnath6324 2 роки тому

    Sir dg working upar video please

  • @miplutclplanning1010
    @miplutclplanning1010 2 роки тому