Kuch months pehly hmary plant pay bhi esa incident hua tha , yahn bhi 5 mega watt ki synchronous motor thi jis ka load compressor tha or us pay maintenance chal rhi thi . (remote) sy operator NY motor run ki or jb off krna chaha to motor bnd nh hue , to emergency main motor ko SGR main present MV panel ka door khol k mechanicaly trip kraya gya tha , reason us ka yehi tha k trip coil stuck ho gae thi.
Sir ek VFD hai jo new install Hui thi 250KW ki motor k liye ACS80 model hai Usme ye problem hai ki jab local mai chla rha tha to sahi chal rahi hai jese hi remote mai daal rha hoon to vo automatically 48 hz tak frequency pe chali Jaa Rahi hai . Aur refrence nahi utha Rahi hai
Sir capacitor apni rating se high current le rahe hain power factor panel mein aur vah bahut haming kar rahe hain iska kya reason hai aur is per video chahie
Very good question Brother Obviously CT step down current and step up's voltage because current and voltage both are inverse..... primary side of CT High current and low voltage and secondary side current is very low in order of 1A or 5A and Voltage is very high which is in order of several KV or MV..... I think your doubt is solved...
Sir make a video for Tap changer of 66/11kv TR with winding (taping) and explain what is normal Tap position.
Much needed video.
Sir kisi bhi motor ya breakers me hipot test kese karte h aur q karte h iss pe ek vidoe banaa dijiye PLZ🙏🙏
Sir, please make videos on electrical troubleshooting. These are very interesting topics.
Sir transformer ka maintenance me keya keya measure karte hay?
Great explanation sir
Please make video on that sometimes in CCR motor is not showing available but from feeder side it is ok or normal so what we want to check first ..
Please explain plc and relay
How they work in control and relay panel for switchyard
Sir how to calculate tempreture in thermocouple and rtd. With calculation
Kuch months pehly hmary plant pay bhi esa incident hua tha , yahn bhi 5 mega watt ki synchronous motor thi jis ka load compressor tha or us pay maintenance chal rhi thi . (remote) sy operator NY motor run ki or jb off krna chaha to motor bnd nh hue , to emergency main motor ko SGR main present MV panel ka door khol k mechanicaly trip kraya gya tha , reason us ka yehi tha k trip coil stuck ho gae thi.
Dri sponge iron wet feeder somporke video banale help hoto and esp bareme
Sir pls make a practical video on racking in & out of CB, TOTAL PROCEDURE
Check my chanel I m uploaded vcb breaker rack in rack out process
Sir breaker mai electrically TNC switch se close nahi ho raha ho toh kya kare?
Sir ek VFD hai jo new install Hui thi 250KW ki motor k liye ACS80 model hai
Usme ye problem hai ki jab local mai chla rha tha to sahi chal rahi hai jese hi remote mai daal rha hoon to vo automatically 48 hz tak frequency pe chali Jaa Rahi hai .
Aur refrence nahi utha Rahi hai
Nicely explained. 👍
Sir capacitor apni rating se high current le rahe hain power factor panel mein aur vah bahut haming kar rahe hain iska kya reason hai aur is per video chahie
Sir please make a video of Excitation system of generator by AVR.brushless AC excitor And discuss about PMG typ
Thanks, Sir for keeping my request. I work as GET in Vedanta Alumina.
MOST welcome Pratyush..
Sir load mode, frequency mode, island mode ko lekar video banaiye
Sir plz make a vdo about why CT is a step up transformer.
Very good question Brother
Obviously CT step down current and step up's voltage because current and voltage both are inverse..... primary side of CT High current and low voltage and secondary side current is very low in order of 1A or 5A and Voltage is very high which is in order of several KV or MV..... I think your doubt is solved...
@@manjunathhosamani2059 thanku sir
Trouble shooting par motor & transformer ACB VCB par video banavo
Sir pls make video for dwarinig electrical wiring
Jayesh,
I have made a whole Playlist for electrical Drawing.
Kindly watch that Playlist.
@@electricalwithabhishekjoshi sir penal ya breaker ki schematic wiring diagram kese read karna or solve problems penal ya breaker
Sir please make video on HT panels protection schemes
Sir vfd ka DO DI & AO AI KO LEKE EK VIDEO BANAYIYE
Why we put CT before CB in 33KV capacitor bank at 132KV GSS.
In general CT put after CB in 33KV outgoing feeders.
Sir please make video on relay PSM and TSM in percentage.... from Hyderabad Telangana.
Sir l can't understand about vfd
Sir g electrical drawing bhi read kena seekhaye please
Sir please make a dedicated video on PSM & TSM of relay
Yes i also want this relay topic
सर हमारे साथ cement मील की मोटर के साथ ऐसा ही हुआ है breaker मैनुअल ही बंद करना पड़ा
Okay.. 👍
Thanks sir
Sir EOT crane one video
Apni retired current se bahut jyada current le raha hai capacitor aur hunting kar raha hai
🙏🙏👍
Electrical Engineer Daily routine work
Shift Engineer Daily routine work
For Interview me pesa jata he
Sir plz explain all these things also in English so that it is easy for preparation point of view
सर हमको लग रहा है कि आप एक ही क्वेश्चन को लेकर गुमराह कर रहे हैं हम लोगों अगर मेकेनिकल स्विच भी कम ना किया तो
सर इस बात से आप आगे नहीं जा रहे हैं एक ही बात को दो वीडियो बनाकर और गोल गोल घुमा रहे हैं
sir pls make a practical video on racking in & out of CB(VCB)total procedure.......
Apni retired current se bahut jyada current le raha hai capacitor aur hunting kar raha hai
Apni retired current se bahut jyada current le raha hai capacitor aur hunting kar raha hai