Introduction to using a scan mode damp meter

Поділитися
Вставка
  • Опубліковано 7 вер 2024
  • Geoff Hunt demonstrates a damp meter with a scan mode including how it works, how to interpret readings and the limitations.
    Geoff is using a protimeter surveymaster www.protimeter...
    Geoff Hunt on Linked in - Reporting and managing defects / 12729458
    Geoffs commisioned Surveyors bone china mugs geoffrey-hunt....

КОМЕНТАРІ • 3

  • @bobrebera494
    @bobrebera494 10 місяців тому +1

    In Florida doing surveys(assessments) and I find that most surveyors(inspectors) need more education and training. Keep up the good work👍

  • @ronangillespie5813
    @ronangillespie5813 Рік тому

    Hi Geoff, thanks for this information. Could you provide some information regarding the render detailing and when it is possible to render over the DPC without causing internal damp penetration? Thanks.

    • @geoffhunt6646
      @geoffhunt6646  Рік тому +1

      Hi. Thanks for watching. In terms of the wall I only used it for demonstration purposes. I happen to know I have a higher spot on that wall as its a single skin garage wall with no DPC. Technically speaking you can put render on a cavity wall because the inner should be separated by the outer. That's not everyone's point of view and lots of people quote the 150mm minimum clear brick to ground level because it is thought that covering the dpc with render creates a bridge. In my experience it does bridge but it takes a long time to become manifest. It's different for solid walls where keeping the dpc as clear as possible is the best plan. Water is a complex chemical so if it can get in it will. Check out NHBC details as they are generally accepted as industry standard even if they don't care to check its built like that!