Slump Test - Which one is Correct as per IS Code | Crystal Clear Concept | Learning Civil Technology
Вставка
- Опубліковано 15 чер 2022
- ✔ Civil Engineer Mukesh Sah YT Channel: / civilengineermukeshsah1
✔Join Us on Telegram: t.me/LearningCivilTechnology
✔Instagram: / learningciviltechnology
✔ IS 1199 - 2018 : drive.google.com/file/d/1EnfQ...
Slump Test - Which one is Correct as per IS Code | Crystal Clear Concept | Civil Engineer Mukesh Sah #learningciviltechnology #civilengineermukeshsah #InterviewTips
✔ Official Website in English
www.learningtechnologyofficia...
✔ Official Website in Hindi
www.civilofficial.com
****************************************************************
ABOUT CHANNEL
✔L & T - Learning Technology: This channel contains Technical Lectures on "Civil Engineering Topics like BBS (Bar Bending Schedule), Quantity Estimate, Rate Analysis, Surveying, Billing Estimate, House Construction, Civil Engineering Interview Question and Answer, Civil Site Related Videos, How to Read Civil Engineering Drawing, Building Estimate, Metro Rail Construction, Basic Civil Engineering Knowledge, Civil Engineering Softwares " from Personal Field Experience by Civil Engineer Mukesh Sah.
CONTACT DETAILS
✔Email Id for Business Enquiry - civilengineeringofficial@gmail.com
✔Twitter: / themukeshsah
✔Facebook Page: / learningtechnologyoffi...
✔ Linkedin: / civilengineermukeshsah
✔Pinterest: / learningtechnologyoffi...
✔Tumblr: / civilengineermukeshsah
Disclaimer:-
Copyright Disclaimer under section 107 of the Copyright Act of 1976, allowance is made for “fair use” for purposes such as criticism, comment, news reporting, teaching, scholarship, education and research. Fair use is a use permitted by copyright statute that might otherwise be infringing.
Thanku sir ji
Very nice sir thank you, finally apne doubt clear kr diya
Thank you sir
Sir apka vidio bahut achha lagta hai
Iske liye bahut bahut dhanyabaad
Simple and good
Make video of flakiness & elongation index limit of CA
Frustum thickness 1.6 mm
Thickness of slump cone 1.6 mm
❤❤❤❤
Sir cube specimen ka dimensions tolerance limit 2mm app ka video ma maina dekha tha oh kon sa is code ma specified hai, is 516 & is 10086 dono ma dhunda nahi mila mujha can you help me? Cube mould ka is 10086 mai hai but muja specimen ka dimensions tolerance limit chaiha during compressive strength checking.
4layer
Informative video sir ji.
Share jarur karna bhai ji.. sabko help mil sake..aur ye confusion dur ho
@@LearningCivilTechnology ok sir ji.
1.6mm sir ji
1.6thickness
Brother, have u pdf about the basic of construction of five stored residential building
building by shallow Foundation. I from Bangladesh. I enjoy ur video even repeatedly.
Oho oho paye gachi
1.6 mm
how many cu.m of concrete may pour per day as per is code ?
Sir, for building we filled cone in 03 layers but for pavement it is advisable to filled cone in 04 layers.
Can you make a video on slab reinforcement as per code in detail ? Thank you
Fourth year
Sir, 6mm
Sir
1.6 mm thickness atleast.
Kya IS 1199:2018 me
Only slump ke liye modification hai
1.6mm
1.6mm thick
1.6mm sir
3 mm
6mm
Thickness of 1.6mm
10mm
Sir thumb rul par bhi video banao
ok
Sir 🙏🙏. Sir why 3 layer?
Thickness of tamping rod Kitna hota hey
16 mm dia
Brick ki compressive strength test ke liye frog me sand fill karna sahi h yaa mortar fill karke test karna sahi h
as per availability but use mortar for accuracy because mortar unit weight 21kn/m3 and brick unit weight 19-20 kn/m3
Jada acha mortor rahega.... Lekin site pe sand se hi kaam chala lete hain jata tar...
@@LearningCivilTechnology ok
@@LearningCivilTechnology flate 🪵
Atleast 0.16cm
IS 1199 part 2 Code ka link nahi mila sir.
Thanks ... Yaad dilane ke kiye.. main bhul gaya tha... Av check kijiye... Mil jayega...update kar dia maine ..
Sir cube specimen ka dimensions tolerance limit 2mm app ka video ma maina dekha tha oh kon sa is code ma specified hai, is 516 & is 10086 dono ma dhunda nahi mila mujha can you help me? Cube mould ka is 10086 mai hai but muja specimen ka dimensions tolerance limit chaiha during compressive strength checking.
atleast 1.6 mm thik
Apke manes kohi hota nahi Sab IS ke manse hota hai
श्री मान आप इतना बारीकि से कैसे पढ़ते हो।
Thanks sir
1.6mm
1.6 mm