RC Beam Design Procedures - Singly Reinforced - Tagalog Tutorial

Поділитися
Вставка
  • Опубліковано 6 лют 2025
  • This video will guide you how to design reinforced concrete beam using flexure formula. The following are the topics:
    Load Calculation
    Steel Reinforcement Ratio
    How to determine beam depth "d"
    Sizing of reinforcing bars
    Difference between singly-reinforced and doubly-reinforced beam

КОМЕНТАРІ • 87

  • @VansEspiritu-cg5vc
    @VansEspiritu-cg5vc Місяць тому +1

    salamat po sir sa tiyaga po nyo para matulungan kami.

  • @Dodroble
    @Dodroble 2 роки тому +2

    salamat po sir sa mga videos mo. malaking tulong po lalo na sa pag refresh sa amin na may konting kalawang na sa pag dedesign.

  • @oceanblue4818
    @oceanblue4818 3 роки тому +1

    Dadami ang subscribers nyo Sir dahil maganda at magaling kayong magpaliwanag!

  • @ajiriltomas9026
    @ajiriltomas9026 3 місяці тому +1

    Im licensed engineer last 2017, pero nagrefresh ako dis 2024.hehe narecall ko naman lahat sa explaination mo sir. Malinaw

  • @alnashierrubio7223
    @alnashierrubio7223 2 роки тому +1

    Panalo sir yung explanation mo po. ❤️❤️❤️ Bug help. Wishing u more blessings and good health. Thank u po

  • @febryugalde4671
    @febryugalde4671 Рік тому

    Madaming Learnings sir, Salamat sa Maliwanag na Explanation sir.
    Sir May simplified Books na Po Kayo sa lahat ng Content nyo na pwedeng Bilhin..Na Pwdeng Pag aralan.....Exciting Pag aralan mga content nyo sir. Subcriber nyo ako sir.

  • @GlennAceret-uv9mx
    @GlennAceret-uv9mx Рік тому

    Engr nakaka refresh ang video mo. Salamat

  • @bamdela6362
    @bamdela6362 2 роки тому

    Maraming salamat po. Laking tulong nito ngayon sa aming mga estudyante. Di gaano nagtuturo mga prof dahil onli r class pa rin.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 роки тому

      Your welcome, I'll make more design related videos to come. Please share it to your classmates. Thanks

  • @jairusfabregas2210
    @jairusfabregas2210 2 роки тому +2

    I really appreciate your content, very helpful po. More videos like this po.

  • @cesarbernardo9961
    @cesarbernardo9961 Рік тому

    Very clear and precise explanation. Thank u

  • @dalegopez4824
    @dalegopez4824 2 роки тому +1

    Thanks po muli...more power po....

  • @jonathanlacayanga5475
    @jonathanlacayanga5475 2 роки тому +1

    Salamat po sa paliwanag. Ang galing.

  • @DRCE777
    @DRCE777 3 роки тому +2

    27:46 Looking forward to this topic also, about T-beams. 🙂

  • @mursiomens1673
    @mursiomens1673 Рік тому

    Malinaw pa sa liwanag thankyou engr :)

  • @lizardo1444
    @lizardo1444 2 роки тому +1

    Thank you po sir. Galing niyo po. God bless

  • @sharmaineantonetteramos2965
    @sharmaineantonetteramos2965 3 роки тому

    Sir thank you so much po sobrang laking tulong. 🤗

  • @jamesardinez9923
    @jamesardinez9923 3 роки тому +1

    Great lecture... More power..

  • @leroy9614
    @leroy9614 2 роки тому

    ang galing nu sir...

  • @ntbnadapa6209
    @ntbnadapa6209 3 роки тому

    sana po Sir, sample din how to compute the shear and moment acting on the beam.
    More power po and thanks for your unselfish sharing of knowledge.

  • @oceanblue4818
    @oceanblue4818 3 роки тому

    Very informative Sir! Thank you!

  • @alexandermunasque2584
    @alexandermunasque2584 2 роки тому

    Maganda yong structural analysis topic Sir.

  • @DRCE777
    @DRCE777 3 роки тому +1

    4:00 I am also hoping for a separate topic for Structural Analysis, I'm sure it will be very useful to tie up the content in this video with Load Calculations.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому +2

      Sure, I will try to make a video about analysis of continuous beam, please stay tune to this channel. Thanks

  • @roneltongco6006
    @roneltongco6006 3 роки тому

    nice explanation sir!

  • @raymondomuk4806
    @raymondomuk4806 3 роки тому

    Tnx sa lecture sir.

  • @jrequilman7497
    @jrequilman7497 5 місяців тому

    Can we adjust the base

  • @pauloprado9487
    @pauloprado9487 2 роки тому +1

    Baka po pwedeng load analysis, 3span na frame, paano po kumuha ng design moment and shear ng roof beams and 2nd floor beams

  • @jhephayudini9275
    @jhephayudini9275 3 роки тому +1

    Sana po meron ding double reinforced beam na explanation sir, mas naiintindihan yung explanation nyo

  • @oliverpalafox5913
    @oliverpalafox5913 3 роки тому

    sana po kayo ang Prof ko nung college

  • @gnidnoeled786
    @gnidnoeled786 2 роки тому

    Sir, ang T = Asfs. Ginawa niyong T = Asfy dahil ang fs naging equals fy due to balanced design? Sa balanced design, steel and concrete yields at the same time?

  • @domza8905
    @domza8905 3 роки тому +1

    Thank you sir

  • @Not_a_Youtuber_
    @Not_a_Youtuber_ 2 роки тому +1

    Sir san po galing yung d= cube root of 130.62?

  • @segundoargota-tu1eo
    @segundoargota-tu1eo Рік тому

    🎉good day sir! Requesting po for catch-up plan if granted. Thanks a lot.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  Рік тому

      Sure. For the mean time, I suggest to visit my channel's playlist "Project Management". It might help a bit.
      Thanks

  • @DRCE777
    @DRCE777 3 роки тому

    16:28 Sir I watched the video, on this part can I ask if this is also applicable to NSCP 2015?

  • @pixelstudio3700
    @pixelstudio3700 3 роки тому +1

    ❤️

  • @kylearkin9924
    @kylearkin9924 2 роки тому

    Good day sir, tanong kulang po sana if pwede po ba magamit yung mga internal forces na nakuha gamit ang portal method sa pag design ng beam?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 роки тому

      If you can perform analysis considering the whole frame, that will give you the cheapest design result instead of treating individually.
      I suggest use any 3D model analysis software then pick-up stress results for sizing of members. Thanks

  • @raymartdelacruz3821
    @raymartdelacruz3821 2 роки тому

    Good day sir . Asked ko lang ganyan po ba kataas balue ng moment sa computation ko ng moment sa beam is 17kn/m2 lang sa dinedesign ko na 2 storey residential house

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 роки тому

      No, follow your assumptions,
      mine is just an example in order to explain design procedures. Thanks

  • @moisesliwanag8602
    @moisesliwanag8602 3 роки тому +2

    Sir can make complete sample calculation for thin walled vessel. Thank you

    • @moisesliwanag8602
      @moisesliwanag8602 3 роки тому +1

      Complete presentation calculation of thin-walled pressure vessel.

  • @francialucido400
    @francialucido400 Рік тому

    Sir bakit po sa factored load ang ginamit niyo po is 1.4DL+1.7LL?
    Di po ba 1.2DL+1.6LL?
    Thank you po.

  • @emilbongbonga9149
    @emilbongbonga9149 2 роки тому +1

    Sir gusto ko po sana makita mga values na ginamit mo sa DL and LL sa first part po ng video, thank you po! God bless!

  • @kebzkebz6437
    @kebzkebz6437 3 роки тому

    16:49 sir, anung ACI code po at anung section ng code? Hindi na po pala Magdedeflect pag nasatisfy na ang steel ratio.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому +1

      Thank you for your comment sir.
      I can't remember the exact section, you can google it. Hindi natin sinasabi na walang maging deflection, what I have said is we are in control of the deflection. Fyi

    • @kebzkebz6437
      @kebzkebz6437 3 роки тому

      @@jsdesign_engineeringtv3633 ok sir. Ang alam ko po kasi kaya natin chinecheck ang steel ratio ay para madetermine natin ang Tamang requirement ng bakal para hindi magkaroon ng brittle failure ang concrete beams. Thank you sir for the new knowledge.

    • @bienramos7587
      @bienramos7587 3 роки тому

      Kung ordinary reinforced concrete po..mag de- deflect po yan Wala po sa code nakalagay na hindi mag deflect ang beam.. except Prestressed/post tension beam pag sobra ang tendon..ang tendency ay mag camber..and that will affect ang floor finishing like tiles..marbles..etc..

  • @reneotejr.3622
    @reneotejr.3622 2 роки тому

    Ano po ba talaga ginagamit sa nscp 2015, 1.2DL + 1.6LL or ung sainyo po?

  • @bonnakid.
    @bonnakid. Рік тому

    sir do you have an excel template for singly reinforced beam

  • @kebzkebz6437
    @kebzkebz6437 3 роки тому

    1:28 sir linawin ko lang po. Pag 1 story po ba na roof deck, Palagi po pala Pinned ang boundary condition ng 4 na beams?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому

      Discretion ng designer yan, some may have treated it as fixed-ended but to me it is safer to let them(beams) free-ended to get the maximum moment at the center. Besides, I don't think column has a complete bending resistance on its free-end. Mag provide ka nalang ng extra top bar on both ends if you wish, use L/5

    • @kebzkebz6437
      @kebzkebz6437 3 роки тому

      @@jsdesign_engineeringtv3633 ok sir. Share ko lang din po sa inyo, pag ang 1 story concrete structure nyo ay nasa seismic or typhoon prone areas, Malakas ang Lateral load at kailangan kontrolin ang Drift. Kung pinned ang boundary conditions ng lahat ng beam hindi po kaya unstable ang structure?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому

      Thanks

    • @generalengineerph3574
      @generalengineerph3574 3 роки тому

      @@kebzkebz6437 in theory.😆Hindi Yan sa totoong buhay.

    • @kebzkebz6437
      @kebzkebz6437 3 роки тому +1

      @@generalengineerph3574 🤣🤣 Hindi Talaga totoong nangyayari sa totoong buhay, bakit? Ilang porsyento ng Mga Structures sa Pilipinas ang Dinisenyo ng isang Structural Engineer?🤔 Dahil Hindi Daw kaya ng Nakararami ang Magbayad ng isang Structural Designer. Kaya Ang mga Contractor satin, kahit hindi capable at wala experience sa structural design ay "Katulad" ng Sinabi mo ang Sinasabi 😉

  • @habitnprofession6088
    @habitnprofession6088 3 роки тому

    May least minimum dimension din po ba ang beam size tulad ng sa column.?

  • @francisbanez6849
    @francisbanez6849 3 роки тому

    Sir tanong ko lang po sa isang frame ng multi storey building pwede po ba gamitin yung pinaka mataas na loads sa structural analysis para sa design ng beams kung typical lengths and section naman po para hindi ko na idesign individually kada beam. thanks po in advance.

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому +1

      Yes especially kung isang type lang ng occupancy. Except dancing hall ang storage rooms, but kung offices, residential, multi purpose with fixed partitions you can assume similar loadings. Liveload lang naman ang variable.

    • @bienramos7587
      @bienramos7587 3 роки тому

      Pag nagde design ako ng multi storey building..let say 20 storey even though same loading..mas malaking size ginagamit ko sa lower level dahil malaki ang stress sa lower level compare sa higher level..gradual lang ang reduced ng dimensions..IMHO

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому +2

      Pwede naman but it would be expensive. Besides, I doubt that it will give you the same result per floor because of the lateral loads. If you want to save time in designing you can group the result like establish a typical zone say; all basement floors, L1-4, L5-8 and so on. It is up to the designer, diskarte mo yan, there is no right or wrong as long as you complied with the prevailing code and assign the proper loadings you are good. Thanks

  • @winefredocerrero2682
    @winefredocerrero2682 2 роки тому

    Sir bka po pwede mag request ng design computation sa steel column

  • @Monroy91079
    @Monroy91079 2 роки тому

    Good day, sir sa load calculation, pwede po b nmen I-apply yung sa tributary, same approach sa column at footing design. .. SALAMAT sir, God Bless po.

  • @mcb-marlito4252
    @mcb-marlito4252 3 роки тому

    Sir JS, pano po lumabas ung 65.31 sa formula nyo ng Mu=0.9*0.009*400+(1-0.59*0.009*400/(21))? iba po kasi lumalabas sa akin using excel spreadsheet formula eh. Thanks!

  • @patrickalmazar2342
    @patrickalmazar2342 3 роки тому

    bakit po 1.4udl+1.7ull ginamit nyo? sanay po ako na 1.2DL+1.6LL ang ginagamit ko pag nagaanalysis

  • @kantdawang2551
    @kantdawang2551 3 роки тому

    Sir kailan Yung lecture niyo sa doubly reinforced?

  • @dennisnadonza9511
    @dennisnadonza9511 2 роки тому

    Sir ano po ang implication kung ang beam mo ay continous beam pero denidesign mo siya as simply supported beam?

  • @lizardo1444
    @lizardo1444 2 роки тому

    Sir paano po makuha ang Beam Self Weight. Thanks po

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  2 роки тому

      You need to get the volume(in m3) first, then multiply it by concrete unit weight (2,446kg/m3)

  • @mobyshun7885
    @mobyshun7885 3 роки тому

    Hindi po ba kasama ang seismic at wind load sa pagcompute ng ultimate load?

    • @jsdesign_engineeringtv3633
      @jsdesign_engineeringtv3633  3 роки тому +2

      I just gave a basic example. That should be included, I will include in my future videos please stay tune. Thanks

    • @mobyshun7885
      @mobyshun7885 3 роки тому

      @@jsdesign_engineeringtv3633 looking forward po sa video nyo about sa pagcompute ng ultimate load

  • @ajiriltomas9026
    @ajiriltomas9026 3 місяці тому +1

    Thank you sir