Slow Sewage - Slow Urinals

Поділитися
Вставка
  • Опубліковано 5 вер 2024

КОМЕНТАРІ • 34

  • @margaretlanger6802
    @margaretlanger6802 4 місяці тому +4

    So many different things that can go wrong with the drainage system, glad we have professionals to fix them!

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому +1

      They definitely can go wrong 👍🏻

  • @tbecause4897
    @tbecause4897 4 місяці тому +5

    The furthest fixture always gets the most use, thus the most problems.
    Human (guy) instinct tends to lead us to the far end, unless it’s already occupied

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому +2

      Furthest away then closest to door and then the middle one is the least used if there are 3

    • @bobthebuilderer
      @bobthebuilderer 4 місяці тому +2

      Nature's unwritten law.

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      @@bobthebuilderer it definitely is

  • @stevem1081
    @stevem1081 4 місяці тому +2

    Had 1 toilet out of 5 at a restaurant that had a problem not Flushing properly, appears the wrong flush valve was installed, instead of having 3.5 gallon per flush, it was only 1 gallon. Changed to the correct flush valve and problem was solved.

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      I think this is probably a similar situation here in don’t get involved to much with clean water but hopefully they get the right person to fix it

  • @peteb3365
    @peteb3365 4 місяці тому +3

    need to instigate a mercy flush policy half way through preceedings 😜

  • @Jim1971a
    @Jim1971a 4 місяці тому +1

    Nice job jetting.

  • @peteb3365
    @peteb3365 4 місяці тому +3

    i agree, to little flush, the water out accelerates the yule log leaving it high and dry 😳 especially if its a large caliber variety....

  • @karencary3312
    @karencary3312 4 місяці тому +2

    Great job!!!! ❤❤

  • @Donald_Turnip
    @Donald_Turnip 4 місяці тому +1

    Thank god that WE don't stuff tampons and baby wipes down the damn toilet!

  • @ScaniaK124EB
    @ScaniaK124EB 4 місяці тому +4

    The flush on the toilets is very poor. The toilet pans only have a small trapway. And with a poor flush of course there is going to be blockages. The owners need to replace those toilets and use high level cisterns.

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      The flushes are awful at this site, you don’t see many high level cisterns in the UK anymore but they would do the job 👍🏻

    • @samuelfellows6923
      @samuelfellows6923 4 місяці тому

      I just about saw the flush button panel for them = those are dual-flush toilets that have not been properly adjusted for half & full flush, by the plumber that installed them and the building management/owner that doesn’t know how to adjust it 😠, those are not “eco-low flush toilets

  • @samuelfellows6923
    @samuelfellows6923 4 місяці тому +1

    1st; 🙄 - mis-adjusted dual-flush toilets. 2nd; the sewage flow in that manhole was weird = flowing away from the Windsor trap (when normally it leaves the manhole through one)

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому +1

      That windsor trap is weird i cant work out why they have done that

  • @lapub.
    @lapub. 4 місяці тому +2

    So many lining in this pipe ! I'd like to know the cost of a line replacement vs many patches and uncloggs

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      I don't get involved in pricing 😂 the thing is its under a building so would be very disruptive to replace

  • @user-tj9sq8nl7n
    @user-tj9sq8nl7n 4 місяці тому +1

    Always so dark in these places

  • @janetsteingold-yt1xu
    @janetsteingold-yt1xu 4 місяці тому +1

  • @james-5560
    @james-5560 4 місяці тому +2

    I think I asked this before, but why can't you pour some hydroclauric acid in each. Leave it 20 mins and it clears it all as it reacts with the urine salts. No need for all the effort with machines and taking apart the plumbing.

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому +1

      Its a H&S insurance thing and carrying chemicals on the van and all that stuff, the reason we don tis more if someone goes in an its still on the urinal and splashes back at them etc we would be liable for it and stuff like that

  • @brucetheloon
    @brucetheloon 4 місяці тому +1

    That blocked server, does the blockage begin forming at the outlet into the manhole and then extend back up the pipe or does it form higher up and then push down towards the outlet? Reason I ask that if it forms at the outlet, would cutting the benching to form more of a fantail maybe prevent the blockage from binding in the first place?
    Also, why is the drain flowing away from the windsor trap? Never seen that before, possible replacement?

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      to be honest there is just so little fall on this pipe it blocks about half way and over time slowly pushes its way thru bit at a time and never makes it with enough flow to the manhole.

    • @Keep_itflowing
      @Keep_itflowing  4 місяці тому

      The Windsor trap is a strange one im not sure why they have done it like that iv never seen one like this before