MOISTURE CORRECTION at BATCHING PLANT I DAILY MOISTURE CORRECTION FOR CONCRETE MIX DESIGN
Вставка
- Опубліковано 18 вер 2024
- #BatchingPlant
#MoistureCorrectionAtBatchingPlant
#MoistureCorrectionForConcreteMixDesign
#CivilEngineeringTutorials
#YogeshKaushikCivil
#UPSCESE #SSCJE #STATEPSCAE/JE #GATE #Quality Control Engineer
In this video, detailed discussion of #Moisture Correction at #Batching Plant For #concrete mix design has been done with its significance, which will be useful for aspirants of UPSC ESE/GATE/PSU's/SSC-JE /State PSC JE/AE exams and Quality Control Engineer on Site.
Following content has been discussed in this video:-
#Moisture Correction at #Batching Plant For #concrete mix design.
Subscribe my you tube channel for further updates / @yogeshkaushikcivil
Bdiya sir ji
Good 👍
Excellent Brother 🤝🤝🤝
Thanku sir ji🙏🏼🙏🏼
Thank you so much sir ji 🙏
Thanku sir
Very good
Nice sir ji
TQ sirr😘😘😘😘❤️❤️❤️❤️
Thank you so much
Super thanks
Hi Sir
I am R.Thiruvasagan
Senior manager quality control
From : TAMILNADU
I just saw your videos 📹. It's superb fantastic 👏 I just saw Daily day moisture correction video . But one dought sir what can we do for heavy rain 🌧 how can we do moistrue correction in batching plant . Can you explain 🤔 in any videos are can you tell it about separate video
Keep rocking 😎 Sir .
Kon sa company mei?
Thanks sir
Hi sir . I am your subscriber sir . I saw your videos they are so good and so clear . I saw moisture correction video
I have doubt sir if I want to do moistrue correction in heavy rainy 🌧 season for RMC plant . The material is too wet what I have to do sir
Please explain Sir 🙏
How water observation calculate??
Dear sir can u just explain why i am adding the adjustment sand in the total sand quantity whats the reason behind it
While evaluating surface moisture, calculation is made with respect to dry weight while u have taken with respect to ssd wt.Furthermore surface moisture of coarse aggregate shouldn't be done in this way as u calculated because it's not customary that coarse aggregate becomes oven dry after 4hrs.
Dear learner
Theoriticallly you are right but in actual conditions, we have to neglect some minor things otherwise project will not be completed on time
Site at admiture add dosages limits how much water add 6cum ?? QC norms
RMC bleeding , segregation concrete slump reject / redose at plant again slump ok is acceptable or rejected as QC norms M30 grade ??
classical
Water observation%
0.61
0.61
1.28 kaha se aaya ?
Ye standard value hai kya?
Ya different different source ke liye ye different hoga?
Plz reply me🙏🙏🙏
0.61 as per design mix h
1.28 mila h site pr
To en dono ka difference compensate krne ke liye hi to moisture correction kiya jata h
Idont understand the water observation table please give the procedure
Sir Engineer ko feeld me kya work Karna padega
How to find out in column c results.
It’s all ready mentioned in mix design
Sir koi IS code jha correction mwntiin ho batching plant ke liye
How to found colum c
Summer time correction moisture content = 0 how calculated
Rainy season correction what difference sir
Please watch video carefully
You will find your answer dear..
. 61 and 1.28 yah standard hai kya.
Sir admixture me koi changes karne padte hai kya ?
No
Sir aapne water obserption lia hai kya ye sirf 1 baar hi lia jata hai jab correction report banate hai
Hr roj correction kiya jata h
1.28 and 1.28 kya hai
Which is code
4925
300°c to nhi karna hai ham 100 ya 105°c par karna hai
Yes
Is code sir
10262
M25 k liye 410 kg !!!
Yes for M25 VDF
M-40 me chalta h 410
Wrong calculation!