Bro we have half the house completed in first floor and we would like to do slab extension to complete the house..will slab extensions are risky and always cause water leeks in future? Kindly respond. Thanks.
Anna.... rebar threading panrathu Nala coupling joints la area of steel Asc reduction irukum ah? Irukum naa enna remedy for that reduction of area of steel? Or coupler will nullify it?
Hi Bro. I need one information. In my home 3 inch concealed led light plastic cup directly installed while roof concrete. Depth of the led box is 3 inch. Concrete width is 6inch without cement plastering. There is no leakage but i am worried about the long term problem. What can i do?
What about the strength of the column bro for coupler vs laping
Good Info
Bro we have half the house completed in first floor and we would like to do slab extension to complete the house..will slab extensions are risky and always cause water leeks in future? Kindly respond. Thanks.
Thank you sir, for your providing us valuable information
Thank you sir 😊
Coupler ku pathil welding panna problem varuma?
Please answer pannungka ?
Bro madi la room yadukumapothu enna material use pannalam brother
Anna.... rebar threading panrathu Nala coupling joints la area of steel Asc reduction irukum ah? Irukum naa enna remedy for that reduction of area of steel? Or coupler will nullify it?
In next video we are going to test the tensile strength…I don’t think there is reduction in Area of steel..
வாழ்க வளத்துடன் நலத்துடன் பல்லாண்டு குடும்பத்துடன் 👍👏🎉
Thank you sir 😊
🤦♂️
As per IS 13920 ductile detailing, column splicing should be at midspan
How much per piece cupler.
I am interested this type .
How it's coupled in top , better explain completely
In our next video I will explain
Hi Bro. I need one information. In my home 3 inch concealed led light plastic cup directly installed while roof concrete. Depth of the led box is 3 inch. Concrete width is 6inch without cement plastering. There is no leakage but i am worried about the long term problem. What can i do?
I think no problem will come …
Thank you bro
l/3 la than column lapping kudukanum..but inga beam joint la ye iruku
👍
Useful one bro
Thank you bro ☺️
new method. chennai?
Lapping should not be done in the tension zone of the column. It should be done in the compression zone of the column (i.e Middle half of the column)
Onnu rendu project panra builders ku k .but huge project ku correct ah varuma
Yes it will
Idhukku coupler avlo vanganume.30% wastage k.intha joiner + machine cost evlo
சர் 20mm debarish அதிகம் போகுமே
What sir ? I can’t understand
Please read my comment and reply bro.. eagerly waiting for your response.