    @EEVblog  6 років тому +130

    Does anyone know the exact legal regulations on non fused transformer primaries in various countries?

    • @N3szt0r
      @N3szt0r 6 років тому +54

      Eu: all mains products have to be primary fused. However chinese products offen are findable

    • @daveturner5305
      @daveturner5305 6 років тому +21

      True but in the EU, if I remeber the regs correctly, that is to protect the 'house' wiring; not the unit plugged in!

    • @sofa-lofa4241
      @sofa-lofa4241 6 років тому +107

      UK consumer electronics regulation 374628/8467-6 subsection 6c paragraph II, clearly states 'Don't let that crazy Aussie bloke plug it in, it makes the pixies mad and you just know that sh*ts gonna happen!'

    • @Pops180
      @Pops180 6 років тому +11

      I dont believe it's a regulation. From what I read, the over current protection is handled where the power comes in (circuit breakers). Only exception is when RMS voltages over 1000 are brought in. Did the circuit breaker in your building not trip? 220/0.2Ohm is 1100A. The breaker should've popped. It also mentions cord length. So maybe if the cord is short enough, you dont need a primary fuse. I guess it's just a shitty way to gaurantee some repeat buys

    • @vcr32
      @vcr32 6 років тому +39

      Dave, I think maybe this was an assembly error. It's possible the fuse is supposed to go on the primary, with the polyswitch on the secondary. Having both in series seems a bit strange after all!

  • @mikeselectricstuff
    @mikeselectricstuff 6 років тому +334

    This was totally caused by core saturation, turning the primary from an inductor to a resistor. It would be more expensive to have enough metal to tolerate a 2x overload.
    Hard to see how it can comply with safety standards to have a 10A capable input connector and no internal fusing. A primary short could potentially dissapate a kilowatt - this has to be a recall-level design flaw. Would be interesting to compare the 230V version.

    • @EEVblog
      @EEVblog  6 років тому +36

      Does anyone know the legal regulations on this?

    • @tomvleeuwen
      @tomvleeuwen 6 років тому +43

      @@EEVblog We once had a floating neutral on our company power net due to a faulty main switch, resulting in 380v between one phase and the neutral instead of 230v (assuming worst case, I was not there to measure). This issue basically blew out ALL the transformers that were connected. Only one catched fire, luckely it was outside, but all of them were broken. I later leaned that it is allowed to malfunction but not to catch fire (as long as it is properly fused), at least in the EU.

    • @AJB2K3
      @AJB2K3 6 років тому +15

      @@tomvleeuwen I remember a customer had a neutral fail on a 3 phase farm.
      480v across a 240v system distroyed everything plugged in including the house wiring.

    • @ald3nt3
      @ald3nt3 6 років тому +27

      Could saturation also kick in due to 50hz mains on a transformer designed for 60hz?

    • @mikeselectricstuff
      @mikeselectricstuff 6 років тому +29

      That certainly wouldn't help.

  • @Manu-nr1yt
    @Manu-nr1yt 6 років тому +208

    Dave get a 240V transformer that fits in there and fix it! Would love to see a repair video!

    • @skuula
      @skuula 6 років тому +22

      Yeah, 24V secondaries are very common, shouldn't be hard to find one.

    • @locouk
      @locouk 6 років тому +2

      Manu _
      I was thinking along the same lines, could a salvage MOT be used stead?

    • @SteveBrace
      @SteveBrace 6 років тому +10

      I reckon Weller will send a complimentary replacement within a week :)

    • @Basement-Science
      @Basement-Science 6 років тому +1

      Green Silver a rewound MOT would be way too big, but in theory, sure.

    • @JustinAlexanderBell
      @JustinAlexanderBell 6 років тому

      This thing will smell so bad after that, doubt he wants it around.

  • @scott8919
    @scott8919 6 років тому +108

    If this were Big Clive he'd plug it back into 240v and see how long the smoke lasts.

    • @qwertyasdf66
      @qwertyasdf66 6 років тому +13

      That's exactly what i thought the thumbnail was, and i waited the whole video for it.

    • @gavincurtis
      @gavincurtis 6 років тому +10

      Then take a deep whiff of it and gag off camera.... did you see the one wher he did that with the fart smell generator? He took a whiff of the concentrate and nearly collapsed...poor guy. Clive is awesome!

    • @ernieschatz3783
      @ernieschatz3783 6 років тому +12

      Electroboom would have broken out the marsh mellows after testing the temp with this tongue

    • @paulstubbs7678
      @paulstubbs7678 6 років тому +10

      Nah, give it to Photonicinduction, he'd wind it up to 600V

    • @SuperStststststst
      @SuperStststststst 5 років тому

      nice

  • @GadgetUK164
    @GadgetUK164 6 років тому +90

    The activity you thought you saw on the LCD - it was the letters H E L, and P. =D

    • @robbieaussievic
      @robbieaussievic 6 років тому +2

      ..... Yeah, I was thinking 'OUCH !'

    • @camelCased
      @camelCased 6 років тому

      SOS

    • @StaticVapour590
      @StaticVapour590 6 років тому +7

      It's made by Weller, so it showed "WELP" on the screen

    • @musashi939
      @musashi939 6 років тому

      @@StaticVapour590 haha. Came for the video. Stayed for a the comments. Bloody good

    • @68MalKontent
      @68MalKontent 6 років тому +1

      Probably it was flashing, because the polyfuse kicked in (and out) several times, until the normal fuse finally blew.

  • @jacobdykstra8499
    @jacobdykstra8499 6 років тому +26

    Regardless of regulation I would expect Weller to spend an extra 25 cents for a fused IEC connector and a properly sized fuse. It would have prevented all this damage from even occurring. The transformer saturated without a doubt and this caused the impedance of the primary to drop significantly which in turn caused the transformer to draw excessive current and burn the enamel on the windings. Had there been a fuse say 5A or whatever it would have blown as soon as the transformer turned on and saturated. The transformer would still be in perfect working condition. The design is unacceptable.

    • @Bulmaimi
      @Bulmaimi 2 роки тому +2

      I just did the same mistake and burnt my brand new Weller

  • @jorno1994
    @jorno1994 6 років тому +75

    at least the ripoff hakko is fused!

    • @mattmoreira210
      @mattmoreira210 6 років тому +6

      Jorno they copied it right where it matters

  • @KCautodoctor
    @KCautodoctor 6 років тому +85

    That product was never tested for use outside of North America, due to it only having a UL Listing for US & Canada (cULus graphic symbol) and no certification marks for any other country safety testing organizations (i.e. AUS, RCM, CE, etc). That product was evaluated by UL under File Number E18708 for Apex Tool Group (aka Weller Professional Tools Division) to the UL Category "KQLR" - Industrial and Laboratory Heaters, which uses UL Standard ANSI/UL499 and ANSI/NFPA 70 (aka National Electrical Code) to evaluate the product. This particular product category does not require additional fusing of the product primary power input, and relies entirely on the branch circuit power protection at the main power panel of the facility.

    • @BruceNitroxpro
      @BruceNitroxpro 6 років тому +6

      KCautodoctor, A sad but true fact... and a cautionary note for people buying in NA.

    • @stragulus
      @stragulus 6 років тому +1

      Shouldn't that at least imply that it cannot be sold as a consumer product?

    • @KCautodoctor
      @KCautodoctor 6 років тому +3

      @stragulus not at all. Check out all the other consumer level soldering models that Weller sells that have been evaluated under the same UL FIle Number E18708 for the same UL Category "KQLR" - Industrial and Laboratory Heaters

    • @stragulus
      @stragulus 6 років тому

      @@KCautodoctor Thanks for that. I guess what I'm asking is, is the intent of that UL category for devices used in labs, instead of consumer homes, and are they abusing this category?

    • @KCautodoctor
      @KCautodoctor 6 років тому +5

      @stragulus that is a common misunderstanding when people see the names UL uses for the category descriptions. It is a carry over from many years ago and no one wants to change the category descriptions since it will lead to more questions about why there was a need for the change (i.e. lawsuits, etc). If the product is UL Listed but was never evaluated for use by an average everyday consumer (a typical Walmart or Home Deport type customer) but rather intended to only be used by a trained professional, then it will include wording near the UL Listing mark that the product is not intended for consumer / home use. UL has the final say on which category a product will be evaluated under based on many factors, including who the customer / end-user will most likely be.

  • @JerryWalker001
    @JerryWalker001 6 років тому +10

    I have designed many transformers and the 'window' of operation is surprisingly small. You basically select a core that meets your power requirements and add a bit (but not much due to size and cost). You then calculate the primary turns required to avoid saturating the core (which is why 50hz and 60hz transformers generally have different sized cores) and the wire size to carry the expected current. The operating range has to take into account the acceptable range of secondary output voltages and in the UK, for example, we have mains voltages varying from 210V up to over 250V so this has a major bearing on the design limits. The outcome of allowing for all variables is a transformer that will generally run into core saturation much beyond the design voltage and at that point it acts like a very low value resistor and soon after that the turns start to short and that causes shorted turn heating so the failure mode is very rapid. The basic safety directive dictates that users should be allowed to blow the crap out of it as long as nothing becomes live and as long as it cannot catch fire (flames, not smoke). Once enough turns have shorted the mains fuse will blow.I think that more recent directives have differing standards for smoke hazards as opposed to electrical safety.

    • @Moonlightshadow-lq4fr
      @Moonlightshadow-lq4fr 10 місяців тому

      I have a 120 volt variac/autotransformer, is it possible to use on 240 if I put a lightbulb in series with the variac. I know the voltage will be the same but will it still over saturate the core?

  • @12voltvids
    @12voltvids 6 років тому +26

    They should have put an MOV across the primary terminals, and a fuse in line.
    My Astron RS35A received 240V when the neutral was broken. This drew 240 across the plugs, when high load appliances (Aid conditioner) in the other phase brought the now isolated neutral to the potential of the other phase.
    My astron belched our some pretty nasty smoke. Opened the unit, the MOV was nice and crunchy and the once clear glass fuse was black as the ace of spades, but the transformer was fine. Changed the MOV and fuse and put it back into service.

    • @davidgriffin79
      @davidgriffin79 6 років тому

      Just like mechanical engineering, electronic engineering is just so incestuous (relatively small circle of people who know everybody else).

    • @BruceNitroxpro
      @BruceNitroxpro 6 років тому

      12voltvids, Fabulous... I will retrofit my new RS35M before mystery smoke does any danger to it.

    • @ernieschatz3783
      @ernieschatz3783 6 років тому +1

      When he described the magic smoke and explained the cause, I immediately though he'd find a crispy-black MOV. I was in a state of disbelief when he opened the cover...like "there's got to be an MOV hiding in there somewhere."

    • @MrJohnnaz
      @MrJohnnaz 6 років тому +3

      Had the same thing happen on a microwave oven, the duplex outlet that it was plugged into had some internal issues, that caused the micro to see 240V as it was on a split circuit.
      Replaced the MOV and the fuse and it is still in service 10+ years later.

  • @anttimaki8188
    @anttimaki8188 6 років тому +3

    I once got a call to fix electrics at construction site. The lights were not working, and a little refrigator was "walking" when plugged in. Problem was that someone before me had connected neutral to 230V making the sockets and lights run at 400V. The compressor of the refrigator was running so hard, it made the refrigator vibrate enough to make it move :)

  • @thinking-laaf
    @thinking-laaf 6 років тому +6

    I had a Weller WTCPT (220V) which I bought decades ago in Europe. When I moved to the US, I contacted Weller, for a possible suitable transformer, and they provided me with a replacement transformer to use it in the US, for a reasonable price...

  • @JohnAudioTech
    @JohnAudioTech 6 років тому +64

    Small mains transformers like this are designed to operate just starting to saturate even at proper voltage. You can observe this by monitoring the current waveform using an isolated scope probe across a low value resistor in series with the primary leads. The wave form gets "spikey" as you turn up the voltage closer to mains level. This is done to allow the minimum number of turns to keep copper losses down for better load regulation and to use the minimum amount of iron core material.

    • @EEVblog
      @EEVblog  6 років тому +15

      That would be interesting to investigate.

    • @WarpRadio
      @WarpRadio 6 років тому +7

      "Billion" brand transformers are known for this.. they usually burn out quickly (short service life) even at rated voltage!

    • @foobarables
      @foobarables 6 років тому +6

      Completely agree on that. Saving money on iron and copper leaves no room for even small over voltages.

    • @MrDoboz
      @MrDoboz 6 років тому +1

      @@foobarables yeah, that was what I was thinking too :P

    • @laharl2k
      @laharl2k 6 років тому +1

      So in summary they play with the fact that the transformer will most likely always have some load from the soldering iron to avoid saturation, much like micrwave oven transformers?

  • @shkhamd
    @shkhamd 6 років тому +20

    lol, my first station was the Weller WES51D bought from US, so 120V version. My mains are 220V and i was as naive as an excited kitty.
    So I plugged the station to mains as soon as I unboxed the station and was watching it heat up, suddenly a big bang and all gone dark.
    Later found that the primary coil was blown. The WES51 is a low wattage station, so luckily in my case, the primary coil of its transformer had finer gauge than the 1010, which lead the coil winding to be blown and then disconnected from the mains in case of the overload.
    This protected rest of the station from being damaged.
    Later, I replaced the original transformer with a local made dodgy 220V compatible transformer which is still working flawlessly for 3 years now.

    • @shkhamd
      @shkhamd 6 років тому +1

      Later I bought the WD-1 from alliexpress and to my surprise, I found that the seller already modded the original station to be compatible with 220V by replacing the original 120V transformer. I never been happier with a station than that.
      Recently I bought this 1010 120V station for another official purpose, but this time I triple checked by my first plugging in with a 220V to 120V step down converter.
      Expensive experience for lifetime for a guy like me, lol

  • @Minifig666
    @Minifig666 6 років тому +9

    The 120V FX-888D throws its primary fuse the moment you give it 240V. Shame Weller didn't fit one I suppose. The 888D fuse is unhelpfully soldered onto the board, which is awkward to fix if it's your only iron!

  • @davida1hiwaaynet
    @davida1hiwaaynet 6 років тому +10

    It's core saturation. There is an interesting experiment to do. Connect a transformer primary to a variac, with a current meter in the circuit. Slowly raise the voltage and go above the transformer's designed input voltage. You will see a sudden rise in current at a certain voltage level as the core starts to saturate. In the USA, we use 120 and 240. Usually the 120V is protected by a 20A breaker; but 240 is used where a lot of kilowatts is needed. It's not uncommon for a 240V circuit to have a 30, 40, or even 50A breaker. So when things do go wrong with 240 in USA the results can be quite dramatic.... and smelly!
    A visitor to went so far as to twist the pins on the cord of my vacuum cleaner so it would fit the 240V air compressor outlet, because it was closer to his car and he wouldn't need an extension cord. You would not believe how much Magic Smoke they managed to pack into that vacuum cleaner when they built it!!!

  • @Kai-io6jn
    @Kai-io6jn 5 років тому +4

    I myself experienced some magic smoke from an film capacitor of an old vcr. It was unfortunately opened when it happened and so it was shooting smoke at the ceiling like some firework. Took hours to get rid of the smoke smell. I was lucky enough to not have my head over the vcr when it happened. It literally took place 3 seconds after I studied the circuit board with my head obviously over the bloody thing while plugged in.

  • @LambdaWave84
    @LambdaWave84 6 років тому +17

    So Weller is shite? Cost-cutting to the point to not include a fuse on the primary side of the mains transformer?

    • @davidwoodbridge862
      @davidwoodbridge862 6 років тому +1

      Weller has always been shite, just most people have never seen or used a real soldering iron!

    • @0dium.
      @0dium. 6 років тому +1

      cut the crap man :) I have an old WECP-20, it was the state of the art 20 years ago, and still decent today !

  • @gizmo69the2nd
    @gizmo69the2nd 6 років тому +1

    I remember my PEBKAC very well. Quick late night repair on small motor driver system.I didn't pay attention when hooking up the new transformer and I switched primary and secondary. Reached over my bench to plug it in ...... Sometimes I still see the flash or feel the bang in my dreams. Luckily we all learn from our mistakes.

  • @gaborballa8566
    @gaborballa8566 6 років тому +80

    I'm shocked! No fuse on the primary side!!! And we are talking about a Weller brand. That's a shame.

    • @gaborballa8566
      @gaborballa8566 6 років тому +8

      ​ Dana Vixen If you watch it carefully you will see that's on the secondary side. It should have protection on both side!! I think a glass fuse is a basic thing to have in circuits like this.

    • @bonzaihb3432
      @bonzaihb3432 6 років тому +4

      @@gaborballa8566 exactly! For that amount of money, even for an entry level device from a supposedly high end manufacturer, this should be mandatory, full stop.

    • @DarronBlack
      @DarronBlack 6 років тому +3

      I've had issues with two WESD51s, including a replacement iron. (Temperature going to 900-ish on the screen and going cold) Shaking the irons usually fixed it, until it progressively got too bad to bother with. I gave up, went with a pair of JBCs. My WES50 lasted well over a decade. I don't think Weller means what it used to as a brand.

    • @DarronBlack
      @DarronBlack 6 років тому +2

      One of the WESD51s started having a problem a week after I bought it... and the replacement iron for the other one worked for 3-5 weeks (don't recall exactly) before it started having issues (but it lasted maybe 4 months before I gave up on it)

    • @pault5179
      @pault5179 6 років тому +4

      Even better HRC sand-filled ceramic, glass can explode with high fault currents ... electronics.stackexchange.com/questions/31366/fuses-what-are-the-practical-differences-between-ceramic-and-glass-cartridge-fu

  • @finkelmana
    @finkelmana 6 років тому +62

    You know, you are always complaining about soldering stations not having the features you want. You are an engineer. Make the perfect soldering station. That would be a a fun series of videos to watch. Electrical design, physical design, CAD modeling, microcontroller programming, etc.

    • @dashcamandy2242
      @dashcamandy2242 6 років тому +26

      The EEVBlog Soldering Station would make a good companion to the EEVBlog Multimeter.

    • @L0j1k
      @L0j1k 6 років тому +2

      I see what you did there. I support this 100%. +1 would insta-buy.

    • @argonathcirith
      @argonathcirith 6 років тому

      Totally agree with this idea

    • @FennecTECH
      @FennecTECH 6 років тому

      Try and make it sub 100 too!

    • @HipocratesAG
      @HipocratesAG 6 років тому +6

      and more important, must be anti-muppets! What kind of moron connect a 120v to a 240v outlet?

  • @gateway8833
    @gateway8833 6 років тому +41

    I know what flashed across the LCD, “I’M MELTING, I’M MELTING. I am somewhat confused about this, almost all of my projects has a smoke discharge, You mean their not supposed to smoke?

    • @LucasHartmann
      @LucasHartmann 6 років тому +2

      I assume it was more like Ahhh

    • @benhetland576
      @benhetland576 6 років тому +4

      Or maybe "DAVE? DAVE, what are you doing, Dave?"

    • @RemyRAD
      @RemyRAD 6 років тому +2

      Any transformer under 18 years of age should not smoke.

  • @TheChipmunk2008
    @TheChipmunk2008 6 років тому +63

    Very substandard construction. No fusing.... No boots or heatshrink on the connectors.. no thermal cutout on the transformer... Not the kind of thing I'd expect from Weller

    • @GoldSrc_
      @GoldSrc_ 6 років тому +9

      Blame Weller, it doesn't matter where it was made if this was how Weller wanted it to be :P.
      Give a skilled worker shit tools/components and the job will end up like crap.

    • @TestECull
      @TestECull 6 років тому +11

      Nothing substandard about it. It was made for the US market and that is perfectly fine in the US market. You don't need boots/heatsrink on connectors that nobody's ever gonna brush a finger or drop a paperclip across, and we don't require fusing or thermal protection on mains devices over here.

    • @TheChipmunk2008
      @TheChipmunk2008 6 років тому +10

      @@TestECull Depends if you're going for the bare minimum or want to protect your brand credibility. And no fusing on a device that could be connected to a 20 amp circuit... but which draws less than 1/2 an amp... is a dick move, no matter which rulebook you're working to. It's pure 'fuck you, mere consumer'

    • @TheChipmunk2008
      @TheChipmunk2008 6 років тому +4

      The lack of boots might even meet proper class II.... but. No fuses, in a place where the plugs don't have fuses? HELL NO

    • @TheChipmunk2008
      @TheChipmunk2008 6 років тому +4

      Hint, i'm not gonna look favourably on weller after this snafu. and someone with actual purchasing power MIGHT feel the same way. Is Weller willing to take that chance?

  • @Rightclick88
    @Rightclick88 6 років тому +12

    Had a similar experience when I worked in a computer store.
    We ordered a power supply for an hp that didn't fit any regular off the shelf power supply. so we shipped one in from a supplier in the US.
    When I ordered I checked if it was rated correctly, and it was. It just happened to be one of those where you have to manually change a small red switch at the back. and by the time it arrived I'd completely forgotten about the fact that it was manually switched, and that it came out of the US so i should at least have checked it.
    as soon as I plugged it in all caps from the psu started venting filling the store with chemical vape.
    after unplugging it, I immediately realised what went wrong and wanted to dig a hole in to the floor to hide my head from my laughing coworkers. that capacitor smell though made me nauseous for a while. spend quite a few days trying to vent it out of our office.

    • @anttimaki8188
      @anttimaki8188 6 років тому +5

      I did similar when i was a kid. My big bro had a new 486, and it had this intresting red switch on the back. Click, and sounds/smells started. I got in a bit of trouble aswell. Fortunately the computer seller was understanding, and gave a new one with the nasty red switch glued over.

    • @Rightclick88
      @Rightclick88 6 років тому +1

      @@anttimaki8188 yeah exactly , fortunately for me only the power supply was destroyed, the computer that belonged to a customer was fine apart from needing a good cleanup. we made no profit on that particular customer, but that still better than having to repair the whole pc at our own expense.

    • @Karreth
      @Karreth 6 років тому

      Yeah, I've done that too. I was 18.

    • @saddle1940
      @saddle1940 6 років тому +2

      Kids do that at schools all the time. They value and treat the PCs with twice the respect they paid for them. Since they were free (to them), well.....

    • @catsbyondrepair
      @catsbyondrepair 6 років тому

      Dumbass did what lols

  • @pfuisi
    @pfuisi 4 роки тому +2

    Hey Dave, Thank you for this video. This is actualy the reason I didn't buy a Weller. I made a video what soldering station I have now purchased and of course mentioned you! Have a great day!

  • @jorno1994
    @jorno1994 6 років тому +36

    no fuse on the primary? come on Weller, even my DIY stuff got one.

    • @glennchartrand5411
      @glennchartrand5411 6 років тому +4

      American electrical code requires a 15 amp breaker on the outlet and GFI protection on any outlet near water.
      We also require double insulation on all tools.
      We place the safety devices inside the distribution box instead of in each appliance.
      Thats something you need to keep in mind when bringing American appliances into other countries.

    • @staevobr
      @staevobr 6 років тому +7

      @@glennchartrand5411 - It is the equipment designer's responsibility to ensure their equipment doesn't not become unsafe. It is not adequate to assume that household protective devices exist or will function to minimize any potential hazards. No excuse not to fuse the primary in this equipment.

    • @glennchartrand5411
      @glennchartrand5411 6 років тому +10

      @@staevobr that transformer was designed for the N.American grid.
      It would have operated safely for a century.
      Here's a litte factoid about American voltage ratings.
      115 V means it can run on 50 or 60 Hertz power.
      120 V means 60 Hertz only
      We created the 115V rating just to let people know if something is compatible with European frequency.
      ( We also put a yellow stripe on the green grounding wire if the appliance can be converted to 220V 50 Hertz.)
      230 Volts at 50 cycle would short out that transformer faster than a fuse could blow.
      It arced through the insulation the moment he flipped the switch.
      We put mustard seed oil in the varnish on transformers so that people can easily see and smell an overheating transformer.
      (thick dark grey smoke with a very strong distinctive smell BEFORE there's an actual fire. )
      Thats why smoke poured out of the thing within seconds of being plugged in to the wrong voltage and frequency.
      The smoke and strong odor he is complaining about is a design feature to grab peoples attention before the transformer actually catches on fire.
      We've been adding mustard seed oil to coil insulation for over 100 years.
      You shouldn't plug in anything rated at 120 Volt on a 50 Hertz supply.

    • @0x8badf00d
      @0x8badf00d 6 років тому +1

      @@glennchartrand5411 Arcs at just 240 Vrms? That would mean not considering PEBKACs, not overspeccing the enamel and getting wire with so thin enamel it could only be used for 120 V.

    • @glennchartrand5411
      @glennchartrand5411 6 років тому +1

      @@0x8badf00d the main issue was the frequency (50 Hertz)
      On transformers the inductive reactance lessens as frequency drops.
      This transformer would have failed at 120v 50Hertz .
      Overvoltage (core saturation) only accelerated the process.
      You've misdiagnosed the main cause of the failure.

  • @jacksat2252
    @jacksat2252 6 років тому +61

    Put the transformer from that crappy Hakko knockoff in the Weller if it is close to 24 V.

    • @Basement-Science
      @Basement-Science 6 років тому +17

      lol that would probably work. And while you´re at it, put its fuse in the weller as well!

    • @MrOrangeman18
      @MrOrangeman18 6 років тому +2

      Jacksat but then it will defo catch on fire:(

    • @scottfirman
      @scottfirman 6 років тому +1

      Thats what I was thinking!

    • @rasz
      @rasz 6 років тому

      MrOrangeman18 no, hakko clone has actual fuse

    • @WaltonPete
      @WaltonPete 6 років тому +1

      @@rasz
      Yes, but I doubt the transformer insulation is anywhere near as good as the Weller transformer.

  • @gavincurtis
    @gavincurtis 6 років тому +18

    Not as big a piece of trash as the Weller WR3M. The vacuum pumps are complete GARBAGE and they refuse to sell the pump as a spare part. They have every other part available though. I have 8 of these and have to pay $400 for the Weller “repair” swap-a-roo center to replace the bad pumps every 1-2 years each unit. I suspect we are getting used pumps pulled from other units, never even getting the machine we sent in back. I sent in a cosmetically perfect machine and what I got back was a piece of tired and worn shit. Whoever used that one liked to use the hot iron tip to turn the power off and on repeatedly!!! The WR3M is $2,500 for 1, so make that 8....that is an investment you respect and take care of. In addition to all scratched and trashed machines from god knows where.....I even get different model versions as a substitute (earlier versions). My glorious armada of pristine soldering stations is now a hodge podge of ghetto trash. Sadly, I have to say avoid Weller as they are going into the toilet like Apple. All they had to do was offer the pump impeller assembly like they do all their other parts and I would be happy. Otherwise, the fact is they are intentionally designed to fail and roll you over the Apple barrel. Go Metcal.

    • @AlexLaw_Qld
      @AlexLaw_Qld 6 років тому

      Nail polish dots tell you what comes back and what is "new". Be paranoid, it can be entertaining.

    • @jamieeast4974
      @jamieeast4974 4 роки тому

      "Milking it comes to mind"

  • @chrisose
    @chrisose 6 років тому +2

    Back in the 80's I watched an entire rack of audio power amps go up in smoke when the electrician wired the stage power distribution to a high leg 3-phase source. Keep in mind this was the days of amps with huge transformers and even bigger capacitors. Well about 3 seconds after the power was switched on most of the caps burst creating a miniature version of 'Towering Inferno". While I wasn't responsible for the power on that day, I made a rule to ALWAYS meter the power before connecting any equipment to it regardless of how safe you think it is. To this day, even though 90% equipment is universal voltage, I meter the power before connecting my equipment to it.

  • @Orbis92
    @Orbis92 6 років тому +48

    I know that smell exactly, since a college connected a 24VDC controlled industrial relay to 230V. The smell from that insulation is very different from that magic smoke smell, because it is called safety smoke ;)
    Btw, I find it very disturbing to have a C14 plug on a 120V only device...

    • @ElmerFuddGun
      @ElmerFuddGun 6 років тому +9

      The IEC connectors are very common on 120V only and 120V/240V manually switched power supplies. Usually not a problem in North America and other 120V countries unless you are doing something unusual like using a 240V/208V UPS that I've seen a person assume would be OK with a computer without noticing the voltage switch on the back of the PS. Just like any power input you shouldn't make assumptions. It happens with "DC barrel connectors" as well. The worst thing is when manufactures don't properly label their products input and output requirements and _assume_ you will never have it near another product with the same connectors!

    • @victornpb
      @victornpb 6 років тому

      In Brazil they have both 120v and 240v both at 60hz so they have the American and eu plugs and use them interchangeable. So 240v outlets are usually labeled as well as appliances

    • @rodgerkitchens7183
      @rodgerkitchens7183 6 років тому +2

      @highks Back in the 1970's, I was on an old Nike-Hercules site in Germany. The High Power Acquisition Radar (HIPAR) used 120V 60HZ power. The rest of our equipment used 120V 400HZ power. We had converters to supply both of these, as well as generators for tactical power. We wound up with outlets for both 60HZ and 400HZ that used the normal US connectors. We also had the 220V 50HZ outlets, but they used the German connectors. You really had to watch what plug you used.

    • @CaspaB
      @CaspaB 6 років тому +2

      I use nail polish on power resistors to make "safety smoke" if they overheat.

    • @dickcheney6
      @dickcheney6 6 років тому +1

      More like a C4 plug!

  • @oldbloke135
    @oldbloke135 2 роки тому +1

    It's not the lack of a fuse that is shocking (no pun intended) a fuse probably wouldn't help anyway. It is the fact that it has an IEC C13 connector, inviting idiots to plug a 230V kettle lead into it. It should have a fixed wire with a 120V plug on it, then at least they have to cut the plug off and wire their own on before they can burn their house down. At least that might make them think for a moment!

  • @KX36
    @KX36 6 років тому +3

    The polyurethane insulation on the wires is definitely sufficient for 240V in normal circumstances. The insulation on the 240V model's primary is probably identical. The problem is that you saturated the core with too many volt-seconds. As you know, once the core is saturated, the winding impedance drops like a stone and the current shoots through the roof. Then the wires overheat, the insulation burns off and the primary short out and then current shoots through the stratosphere. I can't believe there's not a primary fuse.

  • @rodgerkitchens7183
    @rodgerkitchens7183 6 років тому +1

    In the mid 1970's TI made a thermal printer for the SR52 and SR56 calculators. This had a full wave rectifier, with a center tapped transformer. The fuse was on the center tap of the transformer, with no fuse on the primary. They used 1N4004 diodes for the rectifier. A common failure mode for these would form a short. Once one diode shorted, it would overload the others, causing them to short. The PCB would actually catch on fire after this. I worked the the repair center at the time. and saw a lot of these units. I saw a few where the transformer got so hot that the plastic case started to melt. We had to modify these to add a fuse on the primary. I was told that a doctor, who was a friend of the president of TI had his house burn down, due to this problem. That is when the modifications started. I am not sure how many houses TI had to buy because of this design.

  • @RuneTheFirst
    @RuneTheFirst 6 років тому +15

    Several current soldering systems have switch mode power supplies. Service people used to avoiid them because of the noise they generated but these days everything has such a supply so there is no longer a desire to avoid them. The problem with everyone using IEC cords is you can easily plug something into the wrong voltage. That was an advantage fixed cords had over these.

    • @Basement-Science
      @Basement-Science 6 років тому +2

      Honestly you would think that every device sold today would have an SMPS, but apparently it´s not worth investing any development into these products and pay the higher materials const of a mains transformer instead.

  • @DielectricVideos
    @DielectricVideos 6 років тому +1

    I once saw a SMPS with voltage select switch running on 240V with the switch set to 120V... The back-to-back caps on the doubler were rated to 250V on either side, and were presumably running at 340-ish volts each. The output was stable and no smoke was released, despite the mistake not being corrected for over an hour.

  • @redtails
    @redtails 6 років тому +7

    8:58 you call it utter trash, but it does have a fuse, unlike the genuine one lol

  • @tonystr9
    @tonystr9 4 роки тому +1

    we have 2 weller's over 30 years and nothing happened and every one knows never put something 120 in 230 volts try it with your tv a/c or something and there is a fuse a small red one with a termal protection in line

  • @shmehfleh3115
    @shmehfleh3115 6 років тому +1

    Hey, what typically happens to 240v electronics when they're plugged into 120v? Do they simply not work, do they suffer damage, or does anything else happen?

  • @randynovick7972
    @randynovick7972 6 років тому +4

    I wonder if the folks at Weller got a good chuckle out of this. I'll bet they did. Good on ye for sharing the story and aftermath.

  • @hydron7833
    @hydron7833 6 років тому +2

    I've always found that wires contain more magic smoke than anything else. As mentioned by others the earlier Weller units had a fused IEC input, it's crazy not to have anything in the primary circuit!

  • @tuttocrafting
    @tuttocrafting 6 років тому +4

    I just find odd to have a IEC plug on a 110V only device!
    The lack of a fuse in the primary side is really a bad design, fuses and holders are not so expensive!

    • @ethanlamoureux5306
      @ethanlamoureux5306 5 років тому +2

      Here in the US, IEC plugs are ubiquitous, so I wouldn’t look twice at it. However, now that you mention it, I think maybe most devices with an IEC plug also have a dual voltage power supply, while 120V-only devices have the cord hard wired to the device.

  • @fragmaster76
    @fragmaster76 6 років тому +1

    Read somewhere this lamination gets seriously toxic if burned. Is that true?

  • @lonzodaman
    @lonzodaman 6 років тому +6

    "Designed & engineered in Germany"
    As a German, I am ashamed now. Especially because we have 240 Volts in Germany, too.
    EDIT: 230 Volts ;)

    • @marsa74
      @marsa74 5 років тому

      Lonzo Da Man Don‘t feel too ashamed. Weller was founded in Philly, is part of the Apex group, but, yes, they have a branch in Germany. Everywhere around the world you‘ll find stuff claiming „German Engineering“ but copied from a news forum in German language where students discussed their work.

    • @AdaptingCamera
      @AdaptingCamera 4 роки тому

      Actually, you don't have 240V in Germany, only 230V...

    • @lonzodaman
      @lonzodaman 4 роки тому

      @@AdaptingCamera My multimeter agrees with you. But IIRC it was set per regulation in the 80s to a range from 220 to 240 Volts (but I could be wrong on this)

    • @AdaptingCamera
      @AdaptingCamera 4 роки тому +1

      @@lonzodaman Never the less, the AC mains voltage in EU is 230V (+/- 10%) 50Hz. There are some variations, but I have NEVER heard of that large difference, normally only 1-2% up or down. Everything else is very rare. Saying that "we have 240 Volts in Germany" is simply wrong, even if you occasionally can measure 240V, that's not the same as the whole Germany is measuring 240V at the same time.

  • @randycarter2001
    @randycarter2001 6 років тому +1

    It's been my experience there is a thermal fuse buried in the wingdings. Covers both over current and over temp failures. Usually one of the lead outs is silver because it's the lead of the fuse.

  • @AJB2K3
    @AJB2K3 6 років тому +11

    Are you going to add a switch mode psu to replace the transformer and rescue the station!

    • @UnrealTransformer
      @UnrealTransformer 6 років тому

      Don't work because we need AC not DC.

    • @galfisk
      @galfisk 6 років тому

      You don't need to rectify the output of the SMPS if you don't want to (except maybe for feedback purposes).
      Whether the circuit can work with tens to hundreds of kHz AC is another question, but I wouldn't rule it out completely.

    • @johnfrancisdoe1563
      @johnfrancisdoe1563 6 років тому

      galfisk Running 100kHz down that iron cable doesn't seem good from an EMI standpoint. A normal SMPS keeps the higher frequency stuff paths to a few cm at most. But then again it's still longwave with medium wave overtones, so a 2m lead might not be a problem.

    • @uzaiyaro
      @uzaiyaro 6 років тому

      It’s only a 24v output. These things are everywhere.

    • @w9gb
      @w9gb 6 років тому +1

      SMPS, NOT NEEDED.
      Dave just needs to source a COMMON 240 Volt to 23/24 Volt HVAC (heating, cooling) transformer at 2-4 amps that is same size.
      THESE exist .... since those same HVAC transformer suppliers were OEM suppliers for some earlier Weller products.

  • @SavageSmithy
    @SavageSmithy 6 років тому +1

    I dont know much about the general state of soldering irons available to you but I use a number of cheap tenma units for simple led work and they can all take 120-240v. I also have a slightly higher end atten unit that again can take a range of voltages and doesnt care if youre on 50 or 60hz.
    I doubt either of these irons are as expensive as the weller so that thing in my view has no excuse for going pop

  • @bonzaihb3432
    @bonzaihb3432 6 років тому +5

    Wow, srsly? According to Reichelt, this thing (well, the 240V version) is 144€ (edit: reduced, original price around 170€), and it does not have a fuse? Even my el cheapo Xytronic station from Taiwan for 75€, and also the even cheaper 25€ no-name hot air station from China has one. Not impressed at all...
    Edit: and it even does not have a socket for a ground strap? WTF Weller... but surely, the CEO earns enough to afford a Porsche, I guess? m(

  • @robertcrawford7052
    @robertcrawford7052 6 років тому

    Many years ago, I was a tech rep for a printing manufacturer. I needed to repair a board from a printing press at a customer's place and used a standard Weller soldering gun. When I pulled the trigger, a cloud of smoke INSTANTLY (probably not more than 1 second) belched from it. I measured the receptacle voltage and it was 208V. The electrician had apparently wired the circuit to the high leg of a 3-phase system. I am still using that gun 30 years later! I duct taped the outlet and informed the owner of the problem.

  • @gorillaau
    @gorillaau 6 років тому +3

    Who assembled the transformer with brown sugar? :-)

  • @dhpbear2
    @dhpbear2 6 років тому

    I'm guessing you fratzed the primary winding of the transformer. Was it a weird sweet smell?

  • @JanicekTrnecka
    @JanicekTrnecka 6 років тому +8

    Photonicinduction style....

  • @Edu_RJR
    @Edu_RJR 6 років тому +1

    that's a common issue here in Brazil, a lot of people have both "110" and "220" in their homes but forget to check which wall plug is each one

  • @MrDrchernobyl
    @MrDrchernobyl 6 років тому +21

    no fuse on primary side, what a terrible design oversight, I wouldnt expect that from weller

    • @Detroit8V92tta
      @Detroit8V92tta 6 років тому +2

      Yeah I have to agree. It really should have a fuse on the primary winding. However where does it stop? Clock radios? Etc. Hmmm

    • @Pops180
      @Pops180 6 років тому +4

      No regulations call for a input fuse on devices like these so long as the cord is short enough. It's always best to understand the equipment you have .

    • @0x8badf00d
      @0x8badf00d 6 років тому +5

      And they got three on the secondary side. Why not put one fuse on primary, one fuse for the iron and the polyfuse for the control board?

    • @Detroit8V92tta
      @Detroit8V92tta 6 років тому

      @@0x8badf00d..because overvlotage on the primary is a rare occurrence. It was an oversight by Dave. It would be expected that if you are going to plug in a soldering iron you kinda know what you are doing. Sure you can put it a polyfuse for that, and a HRC for this, but where really does it stop. Read the placard is the moral of the story.

    • @Detroit8V92tta
      @Detroit8V92tta 6 років тому

      @@0x8badf00d Fuse on the plug. My original comment.

  • @oleksandrkindras9595
    @oleksandrkindras9595 6 років тому +1

    Even if you can do without an extra fuse somewhere and... save 5 cents I think? It's a shame for Weller. If you are a professional soldering equipment manufacturer, you cannot make expensive and bulletproof stations for professionals and aren't so expensive (because they aren't cheap too) and reliable only if you live in ideal world.

  • @foxpup
    @foxpup 6 років тому +6

    My first son at the age of two had a fascination with electronics and discovered the AC 120/240 switch on the back of computers and reversed the setting. It took a long time to figure out what happened. I'm an American so no magic smoke for me. (Thank God!!) Its funny, now he's a computer hardware engineering student. I should tease him about that now, that and the fact that he effectively demonstrated that you CAN get three CDs in one drive at the same time, but don't expect them to work or be easy to remove. :-) ...oh those were the days. :-)

  • @GlennHamblin
    @GlennHamblin 6 років тому +1

    Insulation wasn't hurt by over voltage, but over temperature, that is what melted the insulation. But yes primary should have been protected.

  • @matthewday7565
    @matthewday7565 6 років тому +3

    I thought transformer laminations were interleaved alternately, rather than all the E stacked on one side and all the I on the other

    • @animatrix1851
      @animatrix1851 6 років тому

      You could do that but you would need the coil to start the interleaving process. If you were to get pre laminated E and I blocks all you'd have to do is weld them together saving you some time.

    • @paulstubbs7678
      @paulstubbs7678 6 років тому +1

      In the early days they were, one could disassemble and rewind with relative ease, unfortunately the bean counters usually insist in a cheaper, non-repairable approach.

  • @randysmith7094
    @randysmith7094 6 років тому +1

    @ 8:02 - Ummmmmmmm, could you re-check the primary resistance without the two blade connectors touching each other please.

  • @brandonupchurch7628
    @brandonupchurch7628 6 років тому +4

    Is there a 240V version of that station that you could by a replacement transformer from that model to repair it. Wonder if the original cord had a fuse in it, some American devices are sold with a removable cord that has a fuse in it (stupid practice , I know, right?) , like sitting next to me right now is a Holmes brand box fan that doesn't have an internal fuse but rather relies on the included removable cord has a one of those slightly modified C7 connectors on it with one square side I'm sure I could find a non fused cord lying around from an old radio or something that would plug into it.

    • @Basement-Science
      @Basement-Science 6 років тому +2

      That´s the stupidest thing I think I´ve ever heard of lol. Fuses in a removable power cord? come on, who came up with that??
      Anyway, he could buy any 240v/24v with a similar power rating and put it in there. No need for anything special.

    • @elvinhaak
      @elvinhaak 6 років тому +2

      I guessed that. Is it still 'normal use' to keep the fuse in the cords? I remember these special cords on computer-equipment (and because we didn't use the cords, we took the fuses out before tossing the cords away when we re-equiped it for 220-230 Volts).

    • @VintageTechFan
      @VintageTechFan 6 років тому +4

      @@Basement-Science Especially if you use a totally common power input connector. If that would have been a proprietary plug, it would still be a stupid idea, but a standard connector? That's just crazy.

    • @jort93z
      @jort93z 6 років тому

      Thats not that stupid. If you have a fuse in the powercord, you can more easily replace it. Easier than if it was on the pcb anyway.

    • @VintageTechFan
      @VintageTechFan 6 років тому +5

      @@jort93z You aren't supposed to replace a fuse on a regular basis. You should think about why it blew. Also .. just put it in a fuse holder on the device like it was done for decades.

  • @Parax77
    @Parax77 6 років тому +1

    Looks like its not just the fuse that's on the wrong side.. that polyswitch would be better over the primary rather than the secondary coil too..

  • @fbach2100
    @fbach2100 6 років тому +5

    My first Weller, that I bought 25 years ago still works fine with it's good old iron core transformer, I'm not sure that an smps would have made it so long without annoying me with dried out capacitors or shorted semiconductor. By the way back then it was quite expensive, especially for my young boy budget^^ , but I can still find spare parts (and not only solder tips !) Can you believe it ?

    • @JanicekTrnecka
      @JanicekTrnecka 6 років тому +1

      Only one explanation..Weller.

    • @DarronBlack
      @DarronBlack 6 років тому +1

      @@JanicekTrnecka It was nice that my local electronics shop had a replacement Weller iron for the WESD51... but when the other WESD51 failed 4 months later they hadn't bothered to restock another iron... so I ordered a JBC (I think because Dave did a video on them?). I bought a second JBC on Cyber Monday (not much of a sale, 10%, but whatever) So far it's pretty nice... but we really haven't had them long enough to know yet. Heats up super fast, hibernates quickly in the stand, and hot-swapping tips is pretty nice. Parts certainly aren't going to be as available, but we got a fair number of tips. The PIN-code settings lock is weird, though.

  • @dandearman2871
    @dandearman2871 6 років тому

    Dave. When it started smoking did you turn it off, yank out the plug or just let all of the rest of the smoke come out? Thanks.

  • @a4000t
    @a4000t 6 років тому +3

    Delete the transformer,install some banana jacks to power it from the shop psu and carry on :)

  • @CoolJosh3k
    @CoolJosh3k 6 років тому +2

    What’s that? We could use a fuse on the primary to protect our customers, but it is not legally required? Sound like a great way to save a cent!

  • @nesnioreh
    @nesnioreh 6 років тому +5

    Obviously not as well built as that grilled cheese toaster. :)

    • @Mike_Downey
      @Mike_Downey 6 років тому

      I was wondering if someone was going to mention Barry's toaster

  • @thisnthat3530
    @thisnthat3530 6 років тому +1

    Back in the early '90s when PC power supplies had the 110/240V switch at the back and the power switch in the PC case actually switched mains (286 and early 386 era), a colleague of mine had just finished assembling a new PC, and pushed the power switch to test. There was a blinding flash like a professional camera flash accompanied by a bang that would have made a .22 pistol proud. Then complete silence in the entire shop (the assembly area was at the back of the display section where customers walked around). I've never seen someone jump back so fast. Turned out the power supply was set to 110V.

  • @michaellowery1559
    @michaellowery1559 6 років тому +14

    Weller, please send dave a new iron.

    • @IIGrayfoxII
      @IIGrayfoxII 6 років тому +2

      I think he has enough "soldering stations"

    • @thomasbonse
      @thomasbonse 6 років тому +1

      @WhiteShadow2k1 Unless you've not left yourself any room on your bench to actually do any work. Then the solution is obviously to get a bigger bench and/or lab.

    • @gorillaau
      @gorillaau 6 років тому

      @@thomasbonse why do you think Dave has upsized the lab. More solering stations and power supplies to be acquired!

  • @allthegearnoidea6752
    @allthegearnoidea6752 6 років тому +2

    No worries mate. Oh well we have probably all done this at some point. It’s funny countries go to some effort to have there own plug and sockets and how easily it’s defeated buy the IEC connectors. From the amount of smoke you mentioned it’s typical of a transformer going up.

  • @pktesla
    @pktesla 6 років тому +4

    take chinese clone apart for transformer (and it's fused connector for a good measure) and fix your mistake xD

    • @xenonram
      @xenonram 6 років тому +1

      Or just buy a transformer. That's like saying, "The transmission in my car just took a shit. Looks like I'll have to buy a new car to take the transmission out of."

    • @ok_engineer
      @ok_engineer 6 років тому

      @@xenonram It's not like he's going to use the knock-off Hakko station so if it's a match, might as well use that because the driver board is a much better than the "Fakko." And regarding your comment, I know countless people who have bought cheap cars from a junk yard and taken the transmission from that.

  • @Elekron5556
    @Elekron5556 6 років тому +2

    Mains transformer not fused on mains side , Fail from Weller :D

  • @neilgower2558
    @neilgower2558 6 років тому +7

    Take it you don't have a fuse in the plug top as we do in the UK..
    Keep the good work

    • @daveturner5305
      @daveturner5305 6 років тому +7

      In the UK the plug's fuse, if correctly sized, is only to protect the house wiring and the cable from the outlet to the equipment. NOT the equipment itself! Using an incorrectly sized fuse , typically using a 13A fuse where a 3A would be more suitable (which now is most of the time) can cause fires as the equipment cable overheats.

    • @willyarma_uk
      @willyarma_uk 6 років тому +1

      That is correct

    • @johnnodge4327
      @johnnodge4327 6 років тому +3

      But having a fused plug is still better than not having a fused plug, even if the plug has a 13 Amp fuse fitted.
      Having said that, 3.1KW of available power in the UK will make a big mess to those tiny primary windings.

    • @Basement-Science
      @Basement-Science 6 років тому +1

      The fuses in UK plugs just allow you to use a thinner cable from the plug to the equipment, that´s about all.
      The house wiring has to be correctly protected by the circuit breakers in the distribution board.

    • @daveturner5305
      @daveturner5305 6 років тому +1

      Absolutely - no contest. We are in agreement.

  • @Damien.D
    @Damien.D 6 років тому

    Brunt solenoids on pinball machine (common failure) looks that way and smell the same, as do AC motor (had a centrifugal starter failure on one, thus over-current, and rotor looked the same). Enamel seems to "boil" and expend from the winding as it heats up.
    The motor was rewound and works like a charm.

  • @RolfRBakke
    @RolfRBakke 6 років тому +42

    Thumbs down for the fake thumbnail image.

    • @subWOOFFA
      @subWOOFFA 6 років тому +4

      I stayed for the whole video thinking Dave wouldnt do that to us

    • @ElmerFuddGun
      @ElmerFuddGun 6 років тому +6

      The thumbnail looked obviously "fake" to me before I clicked on it. Dave's done fake flames before too but they were also obvious. Search back it was a PS from China that Dave was building into a case. Maybe a year ago?

    • @uzaiyaro
      @uzaiyaro 6 років тому +3

      ElmerFuddGun Yeah, same thing with the power supply. But the things weren’t on fire when he was filming. Also, I just got one of those power supplies and it’s awesome! A kilowatt of power for $60! Thankfully, what caused that failure - a bypass/filter capacitor on the output that was susceptible to physical damage, has been completely removed.

  • @nickfatsis9607
    @nickfatsis9607 6 років тому

    In the 80's I worked for a transformer company here in Melbourne, I was an Armature coil winder, the transformer used in that soldering iron is what we called "junk wound" the ones we made used multiple turns of enamel coated copper wire, but we also used to place a sheet of insulating paper between each layer, this limited the chance of a short, in this case, it looks like the enamel broke down because the voltage was too high.

  • @radry100
    @radry100 6 років тому +3

    Doesn't a 120V (US) device have a different mains plug than an Australian 240V one?

    • @jrdnajh
      @jrdnajh 6 років тому +5

      This has an IEC C13/C14 connector which are used in both 120 and 240v areas.
      Really a mistake in the standards if you ask me.

    • @jort93z
      @jort93z 6 років тому +1

      The wall plug is different, but the connector on the actual device is the same. its a standard IEC connector. You can plug any lead with any wall plug into it.

    • @WarpRadio
      @WarpRadio 6 років тому

      its not the plug end.. in his country the IEC end has a 220 plug.. which this situation should NOT have happened as IEC generally means "120/240 compliant".. but, then, China broke the rules!

    • @jort93z
      @jort93z 6 років тому +1

      What do you mean china broke the rules? that weller was designed in germany and made in mexico....
      Also, does IEC mean 120/240 compliant? i don't think that is required.

    • @WarpRadio
      @WarpRadio 6 років тому

      @@jort93z perhaps: but I'm guessing the transformer was from China.. I donno- I was just trying to say that the way things are made today, "its the bottom line that's the most important"; I have had many a 'tranny' fail in some top-notch equipment such as Furman, Sibex, DBX and Mackie.. and they were stamped "made in China"! As far as "120/240 compliant" is concerned, I'm not entirely sure on that, exactly.. I CAN say that MOST of the stuff I have seen with that connector on it CAN accept 120v and 240v (usually by means of a switch) such as computers, and some/most universal pro audio equipment.. but in the states, that connector can also be used on 120v only stuff too.. the problem comes if/when that equipment is taken overseas.. but the stuff that's already overseas, that uses an IEC connector, seems to all be 120/240 compliant. thanks for your comment!

  • @absurdengineering
    @absurdengineering 5 років тому

    The reason it happened may be of interest: it wasn’t an insulation failure or breakdown that precipitated the smoke escape. The high voltage in itself is not a problem at all: the winding and the insulation would have handled it. The problem is that the core was minimally sized and saturated as soon as the voltage got over 130V or so - also since Aussie 50Hz eats away at whatever margins were there in a 60Hz transformer design. I have a similar 120V Weller model and the saturation indeed starts around 125-130V 50Hz. By the time you reach 240V AC on the primary, the winding behaves like a ~50Ohm resistor fed from a 50% duty cycle 120VRMS supply, and promptly overheats, producing the mesmerizing billowing smoke :)

  • @JanCumps
    @JanCumps 6 років тому +4

    primary side will be fused with a hidden thermal fus3 inside the windings ...

    • @mikeselectricstuff
      @mikeselectricstuff 6 років тому +2

      This is less common on bigger transformers.

    • @pierreburton4523
      @pierreburton4523 6 років тому +3

      Yeah.... that's going to help when the windings are already shorted.

  • @retrobrw919
    @retrobrw919 6 років тому +2

    I= 240/0.2 = 1.2 kA
    P = (240V)(1.2 kA) = 288 kW..
    Well... That seems... dangerous?

  • @motormadness9975
    @motormadness9975 6 років тому +5

    How does it take you more than 4 weeks to unpack your lab stuff. Every video you have an excuse why you cant access your gear

  • @MichaelSteeves
    @MichaelSteeves 6 років тому

    After living for years in a 240V country with a bunch of expats from 110V countries, I have seen *many* transformers. It doesn't seem to matter the type of equipment, if you plugged 120 V equipment into 240V you got the magic smoke. Thank goodness for the more recent variable voltage supplies!

  • @ABaumstumpf
    @ABaumstumpf 6 років тому +11

    There should be no way to plug 120/240 Volt plugs into each other.

    • @N3szt0r
      @N3szt0r 6 років тому +1

      Try to avoid that :) likes benzin vs diesel...

    • @christophermurphy408
      @christophermurphy408 6 років тому +6

      The problem is IEC connectors are fantastic for computer equipment etc that is dual voltage however in this case I think Weller should have had a fixed US plug which definitely would make you think twice before putting it on a plug converter.

    • @deceitive3338
      @deceitive3338 6 років тому

      Technically there isn't, a US/Canadian plug won't fit into an Australian (or European) socket, Dave must have been using an adapter here.
      If it had an Australian plug Weller would be liable for any damages...

    • @DanafoxyVixen
      @DanafoxyVixen 6 років тому +6

      @@deceitive3338 "Technically there isn't, a US/Canadian plug won't fit into an Australian (or European) socket, Dave must have been using an adapter here." Nope, no adapter needed as it used a IEC connector to connect to the power lead

    • @deceitive3338
      @deceitive3338 6 років тому +5

      @@DanafoxyVixen Ah you're right, just rewatched. That's awful, devices with an IEC connector should be required to have a 240/120v switch (and appropriate transformer). At bare minimum should be fused. Crazy

  • @LinuxGalore
    @LinuxGalore 6 років тому +1

    you would think Weller would have a multi voltage power supply, it is not the 1980's any more. The company I work for makes electrical equipment and everything we manufacture is mains multi voltage, multi frequency.

  • @jethrobo3581
    @jethrobo3581 6 років тому

    Check the plastic bobbin to see if any penetration from primary to secondary.
    If there is melting and any primary to secondary short, you have a major safety hazard and UL needs to be notified.
    There should have been an internal thermal fuse sitting atop the primary winding.
    We've all seen adapter recalls - major issue.

  • @necessaryevil8615
    @necessaryevil8615 6 років тому +1

    Apparently they use the same connector for 120v devices... That's just a design flaw!

  • @mikewillis1592
    @mikewillis1592 6 років тому +2

    If that is all that is inside - why does it cost so much? At least it is easy to fix but not impressed with the quality of the mains side of it. There should have been a fuse.

  • @polodelmar9852
    @polodelmar9852 4 роки тому

    NEC each receptacle & plug Must match Voltage & Amp. Rated.
    Did you use an adapter of some sort?

  • @YugoZex
    @YugoZex 6 років тому

    How did you get 120 volts unit at all, when you live in 240v country?

  • @irgski
    @irgski 6 років тому

    What was your mains breaker amperage?
    It didn’t pop?
    Also, some E core xsfmrs - rather than the EI you show - use EE interleaved laminates.

  • @HauptwerkHardware
    @HauptwerkHardware 6 років тому

    How is it that they can weld the laminations down one side like that? I thought they had to be insulated from each other, each lamination is usually coated with an enamel or varnish I thought, else why laminate it at all... Anyone know how that works please?

  • @excavatoree
    @excavatoree 6 років тому

    How did you keep the smoke from triggering the alarm? (all the smoke before you stuffed it in the box. Did you have to run down the hall with a smoking box?)

  • @johnjohannesjuan
    @johnjohannesjuan 6 років тому

    one question about the "EI": as far as I understand it, each sheet of metal is insulated, right? why doesn't the insulation get ruined by welding the E and the I together? or is it destroyed locally but it doesn't matter from an eddy current perspective?

  • @barrymayson2492
    @barrymayson2492 6 років тому

    I used to work in the UK for a US company the number of PSUs we blew because we forgot to change the voltage link was staggering. After a while you would automatically check but sometimes if you were in rush magic smoke.

  • @SuperMurrayb
    @SuperMurrayb 4 роки тому

    At 3:48 on the upper right hand corner is a red block in a circle marked "F1". What is that?

  • @linagee
    @linagee 6 років тому

    1:36 Is this a fake, or did they actually spell "Series" as "Serie"? (Lower left corner.) I couldn't find the bottom label anywhere else online, nobody seems to turn their products upside down!

  • @dtimboggs
    @dtimboggs 6 років тому

    Did the plug not give the needed input voltage indication?

  • @kkendall99
    @kkendall99 6 років тому

    Isn't the secondary voltage only determined by the number of secondary windes? If you increase the voltage on the primary all that is going to do is increase the magnetic flux or potential current when the field collapses into the secondary. Or am I missing something?

  • @Pupperoni938
    @Pupperoni938 6 років тому

    Can you still fix it? Do they sell spare transformers, or could you get one from ebay from a scrap unit?

  • @iyatemu
    @iyatemu 6 років тому

    I live in South Florida and a couple of years ago we were hit by Hurricane Irma. A strong gust of wind broke a tree that fell on the power line connecting our house to the transformer, and while it didn't break the line, but it DID break the house's connection to the Neutral. Immediately after, our toaster oven blew (vaporized a ground trace on the power supply board), and a few lights went out, but phone chargers and our air conditioning kept working.
    They kept working of course because the phone chargers are switching supplies capable of handling 240v, and the air conditioner is wired on the 240v single phase coming into the house. Since the tree knocked out our Neutral connection, every plug in the house was suddenly live at 240v, and no one in the house knew. We only assumed some breakers were permanently tripped.
    I collect old computers, and of course I'm worried that some of my stuff was fried, so before anybody actually realizing that everything is live at 240v, I go to check if my Japanese 100v MSX2+ is still working. I plug it in and turn it on and immediately get buzzing from the transformer. It didn't blow and once we got proper power back I tested to make sure it worked, and it did, but I swapped the transformer out for one from another model. The original looked and worked fine, and there was no smoke, melted insulation, or anything else visibly wrong with it after getting almost 250% input voltage for a brief second, so props to 1988 Sony for designing robust transformers, but I still wouldn't trust that transformer for the same second it was plugged in.

  • @chino852456
    @chino852456 5 років тому

    Would weller help fix that? Or is a direct trip to the thrash?

  • @petroldevo9934
    @petroldevo9934 6 років тому

    You might be able to re-wind the primary side if the transformer is serviceable. I used that method in the past, just takes a lot of patience. It would be interesting if you can wire that for 240 ?