Rewiring Second Fix | Electricians Life

Поділитися
Вставка
  • Опубліковано 5 жов 2024
  • Check out Signs And Labels Direct on the link below, the possibilities of the building tool are endless, I just chose to make earthing labels, let me know what you choose!
    👇🏻
    www.sld-ltd.co.uk
    Don’t forget you can get 10% off all verso consumer units using the code “CABLESMITH” at checkout here
    👇🏻
    www.alertelect...

КОМЕНТАРІ • 61

  • @SteveHit1
    @SteveHit1 2 роки тому +3

    A great video, as usual, thanks!
    I think giving the customer a small gift, is an excellent thing to do - it demonstrates to the customer that it’s a superior service that you’re offering and that you care - as does the fastidious cleaning up. (I bet Ryan did that!)

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      Thank you Steve, and noooo I did the cleaning 😏😂

  • @JayTheSparky
    @JayTheSparky 2 роки тому +4

    This is the reason I love the click stuff as you can adapt it like this, you can to a certain extent with a Hager but not like that a three gang switch one a single plate, If you happen to need an intermediate etc you can just pop out and change 👌🏻

    • @Cablesmith
      @Cablesmith  2 роки тому +3

      Yea mate they’re awesome for us traders that can just keep a load of stock and never be caught short

    • @JayTheSparky
      @JayTheSparky 2 роки тому +2

      @@Cablesmith Definitely mate plus the fan Isolator with the fuse built in is a dream too 👌🏻🤌🏻Working smarter not harder

  • @roydowling2542
    @roydowling2542 2 роки тому +2

    Your sticker on the front of the consumer unit looks mint Sean.

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      🙌🏻🙌🏻🙌🏻

  • @martynhogan3654
    @martynhogan3654 2 роки тому +3

    Them little labels are a great idea, like the cable smith sticker on the front of the DB as well 👍

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      Yea I love them! And thank you martyn

  • @ianm1470
    @ianm1470 2 роки тому +5

    Great progress guys well done ~ nice touch with the Cablesmith goodies 👍🏻

  • @kiphakes
    @kiphakes 2 роки тому +1

    Board looks MINT!

  • @chema_lopez
    @chema_lopez 2 роки тому +1

    Great video, thanks!

  • @nibs2344
    @nibs2344 2 роки тому +1

    Fan Isolator look at Click CMA3020, it’s pre built switch and fuse carrier

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Yea I know about these but my wholesalers don’t stock them only the separate modules for some reason 🤷🏻‍♂️😂

  • @sanbucaone
    @sanbucaone Рік тому +1

    Good content Sean, like the idea of the three core to the switch for future proofing. I’m a fan of the click mode range and the modules you use. Small question on the fan isolator and fuse you show. When wiring do you put the permanent line or switch line to the fuse 🤔I assume it would be the permanent line.
    The clean up and small gift is a really thoughtful idea. A bit of professionalism, well done on a good install given the challenging Cable runs. Well done both.
    👌👌

    • @Cablesmith
      @Cablesmith  Рік тому +1

      Hi mate, appreciate the good feedback. As for the fan, yes it’s the permanent live that’s fused. It’s a bit of a misconception with people saying both need fusing to 3A which they don’t.

  • @johnmcgrath4364
    @johnmcgrath4364 2 роки тому +2

    Nice job lads,hate rewires🙈 but getting plenty of work doing them at the minute

    • @Cablesmith
      @Cablesmith  2 роки тому +3

      Thanks mate, I love them but only if nobody is living there at the time, don’t mind if it’s furnished as long as they’re out for a week 😂

  • @adriatikkrasniqi1453
    @adriatikkrasniqi1453 2 роки тому +1

    The video is very good 👍..no complaints about work well done guys..,

  • @Waynesworldofgaming
    @Waynesworldofgaming 2 роки тому +2

    Nice job Sean boy, I always use the black as the switch line too, don’t know why just always have. Those labels look sick though mate 👌🏻

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      I usually use black as the permanent live but that’s just from doing commercial most my life and all emergency lighting Flexes come pre wired like that.

    • @Waynesworldofgaming
      @Waynesworldofgaming 2 роки тому +1

      @@Cablesmith didn’t know that tbf, everyday is a school day

  • @martinburgess2322
    @martinburgess2322 2 роки тому +1

    Nice neat and tidy board. Good work gentlemen 👌👊

  • @JayTheSparky
    @JayTheSparky 2 роки тому +1

    Nice those trunking bends aren’t cheap!

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Oh sh*t I forgot about the price of them bends ! I’ve not had the invoice yet 😭😭😭

  • @ForTheBirbs
    @ForTheBirbs 2 роки тому +1

    Nice work chaps!

  • @gary.corcoran
    @gary.corcoran 2 роки тому +1

    Nice job lads !

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Thank you 😊

    • @gary.corcoran
      @gary.corcoran 2 роки тому +1

      @@Cablesmith I need one of those Cablesmith switchboard stickers in my life !

  • @hasankhan-ey5oz
    @hasankhan-ey5oz 2 роки тому +1

    Nice work

  • @Sg-bi5tw
    @Sg-bi5tw 2 роки тому +1

    What should I expect to pay for 4 Hikvision Colourvu cameras to be fitted, with all the wiring already run to the soffit location? Thanks mate keep up the good videos

    • @Cablesmith
      @Cablesmith  2 роки тому +3

      Depends on wether IP or Analogue version, what cameras and how big of hard drive but personally around £850-1050

    • @Sg-bi5tw
      @Sg-bi5tw 2 роки тому +1

      @@Cablesmith cheers buddy. Keep up the content

  • @Bazza-tn5ck
    @Bazza-tn5ck 2 роки тому +1

    If you do want to save herself 5mins work click mode do sell fused fan ISO’s complete with 3A fuse. 👍👍

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Yep I’ve seen them online but never in stock anywhere I’ve asked for them, only separate modules 😂 typical

    • @Bazza-tn5ck
      @Bazza-tn5ck 2 роки тому +1

      @@Cablesmith to be fair your right, I had to ask my wholesaler to get em in, luckily it’s a small independent place so they did. Probably only used about 4 meself tho, bet their fuming 😂😂

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      @@Bazza-tn5ck always the way 😂 asked mine to get things in stock many times then hardly used it 😬

  • @phillipgwynne6580
    @phillipgwynne6580 2 роки тому +1

    Not too shabby 😂

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Not too shabby indeed 💪🏻😂

  • @therealdojj
    @therealdojj 2 роки тому +1

    those fancy switches, do i need one for the bathroom fan then as mine is just done via the pull switch
    thanks

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      With the 3A fuse you mean?
      Manufacturers will say yes you do that’s why we fit them, but I don’t want to tell you it’ll be alright without one 😂

    • @therealdojj
      @therealdojj 2 роки тому +1

      @@Cablesmith I think that deserves a sub 👍

    • @Cablesmith
      @Cablesmith  2 роки тому

      @@therealdojj legend 👏🏼👏🏼

  • @ACAIDC
    @ACAIDC 2 роки тому +2

    I just have to ask… What’s with the ‘2015’ @14:11?

    • @Cablesmith
      @Cablesmith  2 роки тому +2

      I think it was just under the wallpaper they had stripped off.

  • @Lineandsinker87
    @Lineandsinker87 2 роки тому +1

    I’m not getting notifications when you post buddy. Anyone else had similar issues ?

    • @Cablesmith
      @Cablesmith  2 роки тому +1

      Happens a lot with UA-cam this mate, not sure if there’s a fix for it tbh.

  • @ericthekingthekingtheking4842
    @ericthekingthekingtheking4842 2 роки тому +1

    Do the quenetic switches fit in them click mode grids mate i know they fit into mk grid

    • @Cablesmith
      @Cablesmith  2 роки тому +4

      They do now yea, they recently made a click minigrid Quinetic 👏🏼👏🏼

  • @mikenewman9372
    @mikenewman9372 2 роки тому +1

    Another cheap imported consumer unit installed. Who sells/installs tall RCBO’s anymore? What’s your customer going to do in three years when they want a circuit upgrading or adding and Verso have disappeared so you can’t get their devices anymore, a new consumer unit will be needed costing them again.

    • @Cablesmith
      @Cablesmith  2 роки тому +3

      what consumer unit would you recommend then? as far as I’m aware they’re all imported and any brand can disappear… look at MK, they stopped.

    • @navitascp
      @navitascp 2 роки тому +3

      We have been around for 10 years. And unlike many importing companies we own our tooling and have full control over our production. But you are right MK pulled out of the market, havells have as well, many other “leading brands” have changed their designs so that you cannot fit new devices in an old board.
      Thanks for giving us the opportunity to explain why we are different though ❤️

    • @mikenewman9372
      @mikenewman9372 2 роки тому +1

      @@Cablesmith Hager, Crabtree, Schneider, Wylex have been manufacturing in the UK for over 100 years.

    • @mikenewman9372
      @mikenewman9372 2 роки тому +1

      @@navitascp many of the leading brands innovate and develop new products but you can still get there replacement devices for their units. If you own your own tooling and have full control over production, why do you still produce tall rcbo’s when the leading brands switched to miniature years ago?

    • @navitascp
      @navitascp 2 роки тому +1

      @@mikenewman9372 each of those make their devices in China. Whilst some may do some assembly in the UK the components are from China these days.
      I’m regards to mini RCBOs we do have our range and it’s double pole currently being independently certified by TUV in Germany 👍🏽
      We have spent many years designing this range, and we are proud of the levels of testing and quality we have gone to with the products. So you’ll be reassured to know that we will be around for many years to come 👍🏽