You are absolutely right Paji. Mere Daikin ke ac K installation k time Technician ne Proper 40-45 minutes ke liye Vaccume kiya tha Vaccume pump motor se Phir usne gauge Pressure me check karke required pressure maintain karkemere ac system Ko On kiya. This process takes time that's why some technician avoiding this Important thing. Ac system needs proper Vaccume to give its100% Performance.👍
Mere yhn bi daikan ac laga hai 6 months back.. muje yaad ni ki vacuum hua tha ya nhi? Kya krna chhaiye kuki warranty mein hai??😶😶 working theek krra hai.
@@babitagarg1970 abhi koi fayda nahi hai Ek bar System on ho jata hai Bina Vaccume kiye matlab Pipes Jo installation ke vakt joint ki unme Mojid air air moisture Puri system me fhel gaya hoga. Lekin jabh bhi kich Reinstall kare to Vaccume karvana bhulyega nahi.👍
@@vivekjadhav4984 in my case no i bought ac from Daikin authorised dealer. And they have very good technical staff. And they also gave me one feedback form that you are Fully satisfied with installation process 💙. For any other thing they can demand extra money but for vaccume don't need to give money. If technician is matured enough they will vaccume ac local dealers give installation to unskilled young boys and they will make your installation worst.
For installation and uninstallion always prefer team from brand itself, I have reinstalled ac from local technican now struggling with leakage, low cooling, low aur through, improper installation and many more, at last called service team from brand.
Bhai saab. You have excellent talent of explaining very technical term in a very very simple manner, that even any layman (bilkul gawar) can understand. Most important looks like you value time, no nonsense start and right to the point.
Sir 1 point aur hai, air non condensable hoti hai, jis se compressor aur condenser work karta hai but air condense nhi Hoti to heat load badta hai, per refrigerant condensable hota hai, so Last Agar air hoti to system air ko bina faida khumayega
Sabse bada point sardaar ji jo aap miss kar rahe ho wo ye hai ki system me air hone se compressor ko jyada kaam karna padta hai jisse ki noise jayada hoti hai aur electricity jayada khata hai aur compressor ki life kam ho jati hai. Air jab compressor se jaati hai to liquid me nahin badalti jabki refrigerant liquid me badal jata hai aur high pressure air system me ghumti rahti hai, jisse future me gas leak ke chance bhi rahte hain.
Kya AC ke drain pipe se panni nikalana zaroori he agar indoor unit me paani leakage nahi he me Rajasthan me rahata hoon per yeah per humidity Nahi hoti zada
Aajkal ye sale Installation wale mostly koi bhi Vaccuum ni karta... I also installed LG 1.5 ton split, after talking & fight, still guy didn't do vaccuum...
@@BankerBabuu mera bhi aj hi install hua bhai...hajar bar use bolne ke bad wo vaccum cleaner lene gya...wo usko sath bhi lekar nhi aya tha aur bus 5 min dikhane ke liye lagaya aur bina pressure measure kare hata diya...uska koi interest ho nhi tha vaccum cleaning m....
2 month ago mera ek split ac install hua. Mene technician ko bola vacuum karne ko. But unhone outdoor ke valve ke pass se ek line se gas relise kiya or dusri line pe L- n key se pressure relise kiya then he open another valve. Kya esa karna sahi hai?
Sem mera v esa hi kiya jab maine bola ki ac installation k tym vacuum karna chaiye to wo log bola ki naya ac mai vacuum nhi karna hoga unlogo k pass proper tool's hi nhi tha
I am getting my Split AC installed today and I told technician to get Vacuum on the call. He told me he will do FLASHING. I think it is same to what you mentioned. But I told him to do Vacuum instead. He said he will not be able to do Flashing if he does Vacuum. Let's see what he does after coming home.
Sir mere Lg ka 2022 dual inverter Ac hai Installation k time pe technician ne vaccume nahi kiya tha lagaya tab se Kabhi bhi aaj tak room cooling nahi kiya
Sir mere paas mitshubishi heavy 1.5 ton hybrid ac hai. Kuch din se usmein ek problem aa rahi hai. Jab on karte hai tab 2-3 min baad compressor apne aap band ho jata hai. Technitian ne pcb, capacitor ko ok bataya. Compressor band hone tak 7-8 amp current hi le raha hai. 2-3 technitian ko dikha diya. Unki jab samajh nahi aata to keh dete hai ke iska compressor change karna hoga. Kya compressor change karwa le?
Meri to ac to bdiya chl rhi h .....lekin in baato ka ab aage se dhyan rakhunga.......but paaji ye btao ki jo bahr ke tar hote h copper ke outdoor ke..... insulation ke upar tap lawana jaruri h kya
20-40 min lagte hain -30 tak aane mein. Ab kuch nhi ho sakta... agar koi cooling problem nhi hai to chalao. Otherwise complaint karo ki technician ne proper vacuum nhi kiya.
Maine 10 baar ac lagwaya/shift karwaya hai aajtak kisi ne vaccum nahi Kiya ....next time Naya ac lunga to Bina vaccum ke aaya to bhaga dunga aur company me complain karunga
I have installed a ifb ac and they did not do vaccuming even after having a vaccum pump .My ac must have ran for 10 min or so ... What can I do in this case ?
Sardar ji aap ne ac installation wala video me ye point miss kar diya hai jis ke wajha se maine aaj installation k samaye vaccum nahi kara paya aap wo video delete kar k phir se installation wala video me vaccum wala point add kijiye nahi to meri tarah or bhi koi vaccum nahi kara payega
Hi sir, mera ac main ek minor leakage tha in door flair main, service engineer ne 2 time nitrogen gas hold karke leakage check kiya tha but they didn't vacuumed after finding leakage, then they again refill gas now a days discharge pipe main ice build up ho raha jab ac on kar hara hu but after 5-7 min wo chala ja raha hai.some i fill ke less cooling ho raha hai.plz give solution.
PLEASE HELP !!!!!!!!! I Ordered Panasonic 1.5 3 star AC in Pune. However while installation the installation guy did not vacuum the machine. Unfortunately he "flushed" the pipes in his words and was arguing so much on his clear fault. I stopped the installation after that. He has not run the AC yet. My question here is can i still vacuum the AC? If yes what additional steps are there? Or should i ask for replacement??
You can't do anything now. If possible, complaint to panasonic customer support and tell them technician didn't perform vacuum. Not vacuuming it will give long time issue.
kra sakte h but puri gas nikal kar first nitrogen se pure system ki cleaning hogi taki jo moisture inside h vo saaf ho jaayega nd fir copper pipe and indore ,outdoor unite ka vaccume krke gas fill karega...
Aapko pichli videos me bhi vacuum ke bareme zaroor batana chahiye tha,kyon ki aap ko follow karke hi AC lagwaya tha,but mechanic bina vacuum ke hi installation kiya tha.😢
Sir kya jab brand technician ac fit krne ath h to kya wo vacuum sath mai leke ate h g and kon sa brand ka technician vacuume lekar ate h ya fr sabhi brands apne technician ko vaccume ke liye kehte h
Hi bro, mere pas LG Q18MNZA 1.5TON ka model he, jab AC start karane kar ne ke bad indoor me se thodi-bahut gus ki badu aati he to kya ye problem vali bat he?or abhi 8mounth hi Hua he warranty hi he to kaya kare?
Bhai koi dikkat nahi hohi Vaccum vaha par hi jaroori hota h Jaha pr already fitting ho rakhi hoti h ya pipe pehele se fit hote h Vaha gandgi, paani sab chala jaata h Esliye vaha vaccum.krna compulsory hota h Normally vaccum ki kahi pr aavshayakta nahi hoti To tension mat lo AC ke.maje lo
Bilkul use nahi karna chahiye, only water with mild soap use kar sakte hoo aur uss k baad bhi fresh water se wash karna zaroori hay. Cleaner acidic ya highly alkaline nahi hona chahiye. Mildly alkaline chal sakta hay jaise ki mild soap water.
Sir, suction pressure in my newly installed Mitsubishi Electric AC is 195 and its cooling efficiency is very very low...technician checked and he is clueless that what could be wrong...does the improper vacuum be reason for this?
What if I remove the vaccum pump before opening allen key volve? I actually removed the vaccum pump line from ac before opening allen key volve, and it sucked some air for like 0.5 seconds. Did I ruin my AC?
Yeah, some air entered. After vacuumed, you needed to open allen key valves only then remove the line, this way gas won't let the air in when line is removed. But shouldn't matter much.
Maine 2 sal pahle Panasonic ka split AC liya tha fitting ke time per vacuum to nahin kiya Hua lekin usmein samel ki problem hai Jab outdoor band hota hai tab usmein samel aati hai aur outdoor chalu hone ke bad smell khatm Ho Jaati Hai Kya yah vacuum ki vajah se dikkat ho sakti hai
Gaya me Whirlpool Split AC installation Whirlpool ke Authorised Service center Technician outer unit se hi Vaccume kar AC Start kar dete hai kahne par bhi Vaccume pump ka upyog nahi karte hai.. Halaaki AC Coolling.. Good hai..
agar Technician thodi gas pehle daal de aur phir woh gas puri pipe se hoti hui release kar dein air nikaalne k liye, but vaccum na karein aur baad main full gas release kar dein to kya yeh work karta hai ? Isme kya problem aa sakti hai, detail main batayein
My 2 and half month old godrej 2 ton eon AC was not giving that cooling as expected finally called technician he pointed on vaccume issue which was not done during installation. They are supposed to do it now by taking all gas out and vaccume and refill. But your oil concept is it nor applicable to my ac as well? Then why cooling issue?
@@emmvlogs thank you sir for reply 🙏🏻 bad mein jab ham technician ko bola tha to usne bola ke usne self vacuum kar diya hai. Haier ka new kinouchi model hai cooling capacity 5125w hai bus 6 month hue hain. lekin Cooling bahut perfect kar raha hai. Per tension ho raha hai ke technician to vacuum motor pump se nahin kiya hai na isliye.
Agar apka ac lg ka ho to zaroor karaye , usme 3m pipe lagta hai jiski zarurat nahi hoti bahut case mai but wo log de dete hai , iske wajeh se air jyada reh jaata hai pipe mai to zaroor lg ka karaye
You are absolutely right Paji. Mere Daikin ke ac K installation k time Technician ne Proper 40-45 minutes ke liye Vaccume kiya tha Vaccume pump motor se Phir usne gauge Pressure me check karke required pressure maintain karkemere ac system Ko On kiya. This process takes time that's why some technician avoiding this Important thing. Ac system needs proper Vaccume to give its100% Performance.👍
Mere yhn bi daikan ac laga hai 6 months back.. muje yaad ni ki vacuum hua tha ya nhi? Kya krna chhaiye kuki warranty mein hai??😶😶 working theek krra hai.
@@babitagarg1970 abhi koi fayda nahi hai Ek bar System on ho jata hai Bina Vaccume kiye matlab Pipes Jo installation ke vakt joint ki unme Mojid air air moisture Puri system me fhel gaya hoga. Lekin jabh bhi kich Reinstall kare to Vaccume karvana bhulyega nahi.👍
@@babitagarg1970 jo installation ke time Mojud tha use puch ke Dekhiye. Vaccume pump Ek Motor jesi aati hai. Wo process huyi thi k nahi.
Did he charge you extra for vaccuming?
@@vivekjadhav4984 in my case no i bought ac from Daikin authorised dealer. And they have very good technical staff. And they also gave me one feedback form that you are Fully satisfied with installation process 💙. For any other thing they can demand extra money but for vaccume don't need to give money. If technician is matured enough they will vaccume ac local dealers give installation to unskilled young boys and they will make your installation worst.
If one hasn't vaccumed the split inverter ac before starting what should he should have to do to rectify this mistake?
I wanted to ask the same question.!
For installation and uninstallion always prefer team from brand itself, I have reinstalled ac from local technican now struggling with leakage, low cooling, low aur through, improper installation and many more, at last called service team from brand.
Bhai saab. You have excellent talent of explaining very technical term in a very very simple manner, that even any layman (bilkul gawar) can understand. Most important looks like you value time, no nonsense start and right to the point.
Sir is it mandatory to vacuum the unit when charging full gas?
Sir 1 point aur hai, air non condensable hoti hai, jis se compressor aur condenser work karta hai but air condense nhi Hoti to heat load badta hai, per refrigerant condensable hota hai, so Last Agar air hoti to system air ko bina faida khumayega
Great information sir
Bhai aap ki video bahut hi use full video hoti hai.. Great...
Sir lg ac offering 10 year warranty on compressor , moisture problem will cover or not ... If not vaccum....at time of installation....
Koi answer mila aapko?
Paaji tum ho toh hamari ac hain bhot bhot sukriya knowledge share karne k liye
Sabse bada point sardaar ji jo aap miss kar rahe ho wo ye hai ki system me air hone se compressor ko jyada kaam karna padta hai jisse ki noise jayada hoti hai aur electricity jayada khata hai aur compressor ki life kam ho jati hai.
Air jab compressor se jaati hai to liquid me nahin badalti jabki refrigerant liquid me badal jata hai aur high pressure air system me ghumti rahti hai, jisse future me gas leak ke chance bhi rahte hain.
already installation ho gaya without using vaccum. Ab usko theek kaise karein ?
Sir agar ac laqwa liya hai to kya wo vacuum ho sakta hai??
Hi, agar ac already install kara liya h bina vaccum ke.. tab is problem ko kaise solve karenge ? Kya dubara uninstall kara ke vaccum karana padega?
Sardaar ji jawab do
Gas Nikal kr nitrogen se flush krke vaccum krke gas fil kro
Han sir btao
Same big Question...
Or
Sacrifice
Same question
Kya AC ke drain pipe se panni nikalana zaroori he agar indoor unit me paani leakage nahi he me Rajasthan me rahata hoon per yeah per humidity Nahi hoti zada
Pls reply...Sir kindly clarify ki vaccum bas copper pipe me karwana hai ya aur kahi pe bhi ? Mera ac installation monday hona wala hai
Sirf copper wire ke close loop Mai hi karana hai
..koi dikkat nahi hai..
sir ji installation k time vaccume nahi kiya mechanic ne , and ac bhi cooling nahi kar raha hai. kya problem ho sakti hai.
Same problem
Sir dono copper wire pipe vaccum hoti hai ya only one
Thank you so much sir. At the time of installation my AC technician didn't vaccumed the pipes. What should i do now? Please suggest me .
Don't worry... Chalne do ab use aise hi
@@emmvlogsBhai mera naya AC bhi lagate waqt vacuum nahi karwaya. Abhi toh waise chal rahe hain, lekin next kya karwa sakti hun?
@@laibanush5431 kuch kiya kya aapne
Aajkal ye sale Installation wale mostly koi bhi Vaccuum ni karta... I also installed LG 1.5 ton split, after talking & fight, still guy didn't do vaccuum...
@@BankerBabuu mera bhi aj hi install hua bhai...hajar bar use bolne ke bad wo vaccum cleaner lene gya...wo usko sath bhi lekar nhi aya tha aur bus 5 min dikhane ke liye lagaya aur bina pressure measure kare hata diya...uska koi interest ho nhi tha vaccum cleaning m....
Sir dual inverter vdya ya triple inverter ac
kya voltas ac ke installation ke time vaccum bhi installation charg me include rehta h ya fr uska alg se charge rehta h ?? plz koi bataega
2 month ago mera ek split ac install hua. Mene technician ko bola vacuum karne ko. But unhone outdoor ke valve ke pass se ek line se gas relise kiya or dusri line pe L- n key se pressure relise kiya then he open another valve. Kya esa karna sahi hai?
Sem mera v esa hi kiya jab maine bola ki ac installation k tym vacuum karna chaiye to wo log bola ki naya ac mai vacuum nhi karna hoga unlogo k pass proper tool's hi nhi tha
@@XploreNortheast bhai same with me ab kya kru .. pls help.
@@daringdpk3160 on point
I am getting my Split AC installed today and I told technician to get Vacuum on the call. He told me he will do FLASHING. I think it is same to what you mentioned. But I told him to do Vacuum instead. He said he will not be able to do Flashing if he does Vacuum. Let's see what he does after coming home.
Kya hua @@shLowKey
Sir humre gher ke bhahar nala hai bada wala show wich ac we prefer
Is it mandatory for split ac only or window ac too
Does for vaccuming we need to pay any extra charges?
No
Bhai ji ac ki pipe bend Krna say cooling mai koi problem atti hai kya
Sir mere Lg ka 2022 dual inverter Ac hai
Installation k time pe technician ne vaccume nahi kiya tha lagaya tab se Kabhi bhi aaj tak room cooling nahi kiya
Ager carrier ac ka gas free me dal de to vaccum karwaya ja skta hai kya?
Technician ne self vaccume ki he...kha koi e problem hoga kya?
Sir mere paas mitshubishi heavy 1.5 ton hybrid ac hai. Kuch din se usmein ek problem aa rahi hai. Jab on karte hai tab 2-3 min baad compressor apne aap band ho jata hai. Technitian ne pcb, capacitor ko ok bataya. Compressor band hone tak 7-8 amp current hi le raha hai. 2-3 technitian ko dikha diya. Unki jab samajh nahi aata to keh dete hai ke iska compressor change karna hoga. Kya compressor change karwa le?
3:08 air nikalne ke liye vaccum karana hai mathlab phir air daala na hai.... Ye samajme nahi aara mere ku
Thanks sir Ji bahaut hi badhiya tarike se apne samajaya or samaj aa bi giya❤❤ very very thanks
Sir my ac installed without vaccum .. pls suggest me what should i do.
Don't worry bro. In future... Gas low problem means... Contact proper ac mechanic and tell him to vaccum and install
Install karke ek din chalne ke baad karwa sakte hain?
👌ਬਹੁਤ ਵਧਿਆ ਦੱਸਿਆ ਭਾਜੀ... You have a vast knowledge 👍
Pata Nahi kyu mujhe sabhi Sikh log Bahut ache lagte hai
Kyuki, singh is king
@@harvinderdhillon3475 🥰🥰
Sir new ac fitting bahar se ya khud kr skte hai kya warranty avoid ho gee
Thank you, for your informative video.
Thank You for this video!
Meri to ac to bdiya chl rhi h .....lekin in baato ka ab aage se dhyan rakhunga.......but paaji ye btao ki jo bahr ke tar hote h copper ke outdoor ke..... insulation ke upar tap lawana jaruri h kya
Sir ye vaccum jab install krwae tabh hi krna hai na, alternative service pe toh nhi krwana hai???
Thank u sir for making this video. But tab kya karna chaiye jab technician ni kar ke jaye.. ab kya karein sir
Sir mene ac install karvaya tha to ac tecneshian ne -2 tak kewal vaccum kiya tha to kya kare please reply
20-40 min lagte hain -30 tak aane mein. Ab kuch nhi ho sakta... agar koi cooling problem nhi hai to chalao. Otherwise complaint karo ki technician ne proper vacuum nhi kiya.
Vaccuum reading wise kitta hona chiye meter me?
Sir ji mene abi new ac lya h wo colling nhi kar kra room me to company wale ne vaccum karne ko kaha h... problem solve ho jayegi vaccum se???
Same problem
Fix hua kya bhai???
Problem solve ho gaya kya bhai please batao
just abhi bhaga dia vaccume macine nahi laya tha😢
Bhai fr dowara aaya vaccume machine leke?
Reply
Vacum ke 500 extra mang raha
Maine 10 baar ac lagwaya/shift karwaya hai aajtak kisi ne vaccum nahi Kiya ....next time Naya ac lunga to Bina vaccum ke aaya to bhaga dunga aur company me complain karunga
Aj ac install hua but chalu niya kiya due to electric kam baki hai to meh kya vacuum karva sakta hu
I have installed a ifb ac and they did not do vaccuming even after having a vaccum pump .My ac must have ran for 10 min or so ...
What can I do in this case ?
Aapko vaccuming karwani chahiye
@@VikasKumawat1992 Even after ac has started.
Would it help
Same ques. I purchased ifb ac 10 days ago and they didn't vaccum it. What to do now
@@tarungupta7751 it will cost you more if you will vaccum now. If anyone is using AC without vaccuming then it's performance is reduced
Well I complaint to Ifb and my vaccuming is getting done as I type this msg just for my satisfaction.
Nice sir good idea
very good information sir ji..
Sardar ji aap ne ac installation wala video me ye point miss kar diya hai jis ke wajha se maine aaj installation k samaye vaccum nahi kara paya aap wo video delete kar k phir se installation wala video me vaccum wala point add kijiye nahi to meri tarah or bhi koi vaccum nahi kara payega
Ssa virji. Virji mere pass voltas ka 1.5 ton split ac hai. Uske compressor ke thimber baar baar jal jaate hai. Iska solution kya hai ji ?
Grace laga bhai
Hi sir, mera ac main ek minor leakage tha in door flair main, service engineer ne
2 time nitrogen gas hold karke leakage check kiya tha but they didn't vacuumed after finding leakage, then they again refill gas now a days discharge pipe main ice build up ho raha jab ac on kar hara hu but after 5-7 min wo chala ja raha hai.some i fill ke less cooling ho raha hai.plz give solution.
PLEASE HELP !!!!!!!!!
I Ordered Panasonic 1.5 3 star AC in Pune. However while installation the installation guy did not vacuum the machine.
Unfortunately he "flushed" the pipes in his words and was arguing so much on his clear fault.
I stopped the installation after that. He has not run the AC yet.
My question here is can i still vacuum the AC? If yes what additional steps are there?
Or should i ask for replacement??
You can't do anything now. If possible, complaint to panasonic customer support and tell them technician didn't perform vacuum. Not vacuuming it will give long time issue.
Dar ji tusi great ho yaar
Sir humne without vaccum ke installed kardiya hain technician ne baad mein abhi karwa sakte hain kya
kra sakte h but puri gas nikal kar first nitrogen se pure system ki cleaning hogi taki jo moisture inside h vo saaf ho jaayega nd fir copper pipe and indore ,outdoor unite ka vaccume krke gas fill karega...
Aapko pichli videos me bhi vacuum ke bareme zaroor batana chahiye tha,kyon ki aap ko follow karke hi AC lagwaya tha,but mechanic bina vacuum ke hi installation kiya tha.😢
Ek badiya vackum pampu konsa hota hai
Sir ji ac lagaye 3 Sal ho chuke ab Garmi suru hone vale he service ke sath sath veccume karva sakte hai
No need if machine is working well
Friends... Vaccum process is 100% compulsory for ac installation....
Do we need to vaccum every time if there is leakage and needs to fill ac gas after fixing leakage??
no
SUPER USEFUL BRO THANK YOU VERY MUCH !!!!!!!!!!!!!!!!!!!!1
Thanks sirjee achchi jankari mili 💟
Sir ji snow wala ac cleaner jo aata hai uske baare me vedio bana dijiye
Sir kya jab brand technician ac fit krne ath h to kya wo vacuum sath mai leke ate h g and kon sa brand ka technician vacuume lekar ate h ya fr sabhi brands apne technician ko vaccume ke liye kehte h
तेरी बात तो समझ गया लेकिन typing सही से कर😂
Village Area ke technician ke paas vaccum nahi hota to kaise install kar waee ??
KYA WINDOW AC ME BHI KRANA HOTA H VACUUM.??
Ac ko continuosly kitni der chla sakte hai
Kitane minute tak vaqume kararwana chahiye
Bhai mera wala technician vaccum nhi kiya , aise hi connection kar diya, voltas ka hai AC
Sir ji installation ke time mujhe ye baat pata nahi this. Kya main ab karva sakta hu?
Hi bro, mere pas LG Q18MNZA 1.5TON ka model he, jab AC start karane kar ne ke bad indoor me se thodi-bahut gus ki badu aati he to kya ye problem vali bat he?or abhi 8mounth hi Hua he warranty hi he to kaya kare?
Lodge a complaint
Sir maine 2 lloyds ac lagwaye hai abhi ... technician nai bina vaccum kiye ac install kar diya hai ab kuch kar sakte hai ya....
Bhai koi dikkat nahi hohi
Vaccum vaha par hi jaroori hota h
Jaha pr already fitting ho rakhi hoti h ya pipe pehele se fit hote h
Vaha gandgi, paani sab chala jaata h
Esliye vaha vaccum.krna compulsory hota h
Normally vaccum ki kahi pr aavshayakta nahi hoti
To tension mat lo AC ke.maje lo
Sir mene purana AC lagaya he to vo dopehrko cooling nahi kartahe rat ko kam karta
Mene new ac lgya he lekini vacuum nhi kiya ab koi problem to nhi hogi?? Blue Star non inverter 1.5 tn ka he
Same problem answer sir
Pajji ye jo chemical wala coil cleaner aata hai usse coil ko koi harm to nhi hota or ye coil chemical se clean karni chahiye ya nhi
Harm hota hai agar baar baar chemical se service karvaoge to
Bilkul use nahi karna chahiye, only water with mild soap use kar sakte hoo aur uss k baad bhi fresh water se wash karna zaroori hay.
Cleaner acidic ya highly alkaline nahi hona chahiye. Mildly alkaline chal sakta hay jaise ki mild soap water.
Sir, suction pressure in my newly installed Mitsubishi Electric AC is 195 and its cooling efficiency is very very low...technician checked and he is clueless that what could be wrong...does the improper vacuum be reason for this?
might be or impure gas
@@emmvlogs thanks 🙂
Sir AC Installation ke time gas company ki or se aati h ya technision dalta h
Its already stored in outdoor unit by company. After installing and vacuuming technician release it
Zabardast information bro
Sir kya amazon ya flipkart se Ac Lena thk rahega kya koi dikkat to nahi aati h warranty me ya product original please reply
Koi dikkat nhi hoti' warranty toh company deti hai
Aap ke advice se maine ftkz model liya lekin wo sahi kam nhi kr raha shayad technician theek nhi hai
Isliye aap dhang ke technician se install karwaiye
Hello maine abhi split AC liya Hain Panasonic ka 2023 model Feb ka but installation walo ne vaccum nhi Kiya h kya ac main ab koi problem aaegi !?
Flipkart se ya Amazon se liya tha?
Meri bhi same ac h.....vaccum ke bare me pata nhi tha.....ac to sahi chal rhi h....kya kre
Sir i have whirlpool magiccool ac 1.5ton...usme E5 display pe show kr rha hai....aaj hi ac lgwaya h 13july ko...cooling ni kr rha aisa kyu
Coustomer care ko phone kro
Hm gareeb admi mehnat se paisa kama ke ac lgwaya h to apne ko to dukh hoga na jha 200 400dene pad gye
@@granddaddy9 Nahi bhai 1year tak warranty h
Merpe bhi whirlpool ka ha
@@shubhamsharma3_ ha vo to hai...but mai replace ki baat bata rha hu
@@granddaddy9 vo tho na ka Barbar ha krege !
Mera tho sahi chl ra ha 1.5 ton 5 star ka
Thank you pajee for information 😊
What if I remove the vaccum pump before opening allen key volve?
I actually removed the vaccum pump line from ac before opening allen key volve, and it sucked some air for like 0.5 seconds.
Did I ruin my AC?
Yeah, some air entered. After vacuumed, you needed to open allen key valves only then remove the line, this way gas won't let the air in when line is removed. But shouldn't matter much.
Maine 2 sal pahle Panasonic ka split AC liya tha fitting ke time per vacuum to nahin kiya Hua lekin usmein samel ki problem hai Jab outdoor band hota hai tab usmein samel aati hai aur outdoor chalu hone ke bad smell khatm Ho Jaati Hai Kya yah vacuum ki vajah se dikkat ho sakti hai
Thnks veer g is maater te video bnaun lyi g
Paji, maine parso hi Ogeneral ka itne expensive split ac lekar install karwaya par technician ne vaccum nahi kiya, ab kya kar sakte hain?
Bhai complaint kr do online customer care par
@@AjayYadav-vf1fm bhai ek baar outdoor unit se gas flow ho gayi toh ab complaint karne se bhi kuch nahi ho sakta
Complaint karo ki technician ne install manual ke according vacuum nhi kiya. They should vacuum your unit and refill it free of cost.
Bhai mene abi apna new ac lagwaya he bande ne vaccume to kara nhi direct on krdiya to kya ab kuch hoskta he?
Same here bro
Cooling kar raha hai ya nhi
@@appukarsh1775 cooling to vip kr rha he
Thanks for sharing the important & knowledgeable information. Thanks so much 👍
Gaya me Whirlpool Split AC installation Whirlpool ke Authorised Service center Technician outer unit se hi Vaccume kar AC Start kar dete hai kahne par bhi Vaccume pump ka upyog nahi karte hai..
Halaaki AC Coolling.. Good hai..
Agar ac install kerwa liya ho to ab kya kre paaji??
agar Technician thodi gas pehle daal de aur phir woh gas puri pipe se hoti hui release kar dein air nikaalne k liye, but vaccum na karein aur baad main full gas release kar dein to kya yeh work karta hai ?
Isme kya problem aa sakti hai, detail main batayein
Just Grt sir ji..
15 days hue hain split AC install ko lekin installer ne vaccum nhi kiya tha to kya ab ho sakta hai vaccum? Must reply..
Same here
important info 👌
My 2 and half month old godrej 2 ton eon AC was not giving that cooling as expected finally called technician he pointed on vaccume issue which was not done during installation.
They are supposed to do it now by taking all gas out and vaccume and refill.
But your oil concept is it nor applicable to my ac as well? Then why cooling issue?
muhare compressor me purana technology ka oil hoga
New ac install karneke samay technician ne vaccum nahi kiya tha. To koi problem ho Sakta hai kya? Lekin ek baat ac colling achha hi kar raha hai.
most nahi karte, chalate rahiye aap jab tak cooling me koi problem na aaye
@@emmvlogs thank you sir for reply 🙏🏻 bad mein jab ham technician ko bola tha to usne bola ke usne self vacuum kar diya hai. Haier ka new kinouchi model hai cooling capacity 5125w hai bus 6 month hue hain. lekin Cooling bahut perfect kar raha hai. Per tension ho raha hai ke technician to vacuum motor pump se nahin kiya hai na isliye.
सर हमने नयी ऐसी लगाई पर उसने व्यकूम नही किया वोल्टास सर्विस सेन्टर वालो ने।
इनका तो धरम हो गया है
मैने भी voltas 1.5 लिया है वैक्यूम नही हुआ बोले जरूरत नहीं है
Agar apka ac lg ka ho to zaroor karaye , usme 3m pipe lagta hai jiski zarurat nahi hoti bahut case mai but wo log de dete hai , iske wajeh se air jyada reh jaata hai pipe mai to zaroor lg ka karaye
Very nice video thank you sir