It may be the most realistic wiring diagram i have seen in my life because this is exactly what you se when you remove a panel. Embrace the spagetti wiring.
This really is great,straight info from a guy who does this everyday.I know really smart people look at this and think so easy,but since I'm not so smart,it seems complex to me.
Much appreciated! I am in my last semester of hvac school and we have a walk-in freezer that hasn't run in years. We have a new instructor and much of our training is self taught. This video should help our group get this mistreated freezer back online! lol
Thank you for this!! I have mentioned before that my mentor passed away March 2020. This and the walk in cooler wiring were two lessons I still needed to fully understand. (I have done this following direction but did not really "see it".) Now I have your saved videos when I need them. Again, I know it takes time and energy to do this for those of us with less experience. Big hugs for big thanks!!! 🤗🤗🤗
Covered this in trade school a lifetime ago, but with no "hands on" experience, remained a bartender for far too long. Had been in F&B operations for 35 years, barback to management, got bored with pushing paper and for the past five years to chase the blues, as a sideline distraction, have been more or less handling most of the fridge work, (with varying degrees of success and flaming failures) at a horse race track / music venue where I still spend more time pushing paper. Attended Bryan Orr's first symposium pre-pandemic and met Dick Wirz. 40 years later...watching your back of a cocktail napkin scribbles with free verse keeping it real rambling video has connected more of the dots between my ears than any of all the above. Be well amigo, would love to ride shotgun with ya one early morn!
Another nice job Dave, it does get “ busy” in that evaporator at times especially when someone uses all black wire, lol.I found a “missing” defrost timer years ago in the janitors closet at a bakery? The owner thought it was the timer for the parking lot lights 🤣
Good explanation on the wiring. To remember the red brown and black wiring positions, I carry the Dick Wirz refrigeration book in my truck, for the three wire control. Some use two klixons instead of the three wire, Some mount on the tube sheet end of the box while others mount on the 180 bend. The electronics are eliminating much of it now.
I saved this to my UA-cam account I have another one of your defrost videos saved in school they taught us that if you draw it you can wire it from memory gonna have to draw this a few times. Great video thank you for sharing your knowledge and teaching us to be super techs
Thank you so much for this great information. I have a question about reach in freezer box the wiring box before to the main control in the condeser. Some relay and a control of wires
I definitely got the evap side of it but how does the control voltage get to your contactor up top? Am I bringing #4 from my defrost clock up to one side of the coil voltage on my contactor and the other side goes through my low pressure/high pressure switches?
the time clock controlls your solenoid valve coil. the condensing unit is on its own circuit and the psi switch controls one leg of your contactor. hope that helps.
Thanks for this great information . I learn a lot of this . But i need some information how to wiring the reach in freezers because it has a lot of relays and controls
Thank you for this video. When you say, that activated "half of the evaporator fans" and then the "fan delay activates the second half". What do you mean by that? All 3 fans run at lower RPM (half speed) first and later on at full speed? Or does it mean that only half of the fans run first and the other half do not at all but only later are turned on when fan delay has reached 35°F? So, do "half fans" refer to lower RPM speed or only half of the fans are running at first stage?
@@NorCal-refrigeration what if there’s no wire going from 1 on the roof top timer and the evaporator. Would you go 4&N so the heater is energized for the majority of the run time and just not during defrost?
@@chrisbivens5410 gotcha you could try that if the line freezes up might have to run a circuit to it 115 volt and a 115 volt heater. I’ve seen that a lot also.
Where can I get 240v to power the A421 when converting from mechanical and the defrost clock (terminal 1) is on the condensing unit? Seems only N is always energized. I've been having to feed in a neutral and run the stat 120v but wish could just use the wiring already available in the freezer evap.
Working on a turbo air evaporator. Curious.. the freezer was at 65 degrees ( room temp) we couldn't get the fans to kick on to cool the room down. The compressor kept kicking on and off because of low pressure. Does the evap cont. to do that till the fan delay gets to 35 degrees?
im trying to process this. I think I got a grip on it. When not in defrost and no call for cooling common sits at the fan delay not actually running fans unless there’s a call from the stat opens the solenoid pressure switch makes temp drops below fan delay set point in which then it makes. Fans run. Defrost time starts. System pumps down? Heaters run? Until either time is complete or temp on defrost term makes in which we repeat first step.
As long as the box is below 35 the fans always run until defrost. Defrost timer drops one half of fans ( 230 volts ). Usually defrost gets coil above 35 degrees and after defrost the compressor will run with less load on it. Until coil gets to 35 degrees. That’s what the fan delay is in there for.
Can I use a 8145-20 time clock to replace a 8141-20. I know the 8141 has 2 nc contacts but the freezer seems it only needs the cooling and defrost only? It’s a norlake old capsule type WI.
And 95% of electricians are stumped... They do not understand how condenser and evaporator work in conjunction without electrical circuitry Dad always said; “wired in series” while Clifford the electrician looked dazed and confused.... Great job Dave!
Great learning videos! I appreciate it! Would you be doing piping as well? Meaning about hot gas bypass? I was working on a walk in cooler but it had 2 liquid lines and 1 suction. I think the other liquid line was part of the hot gas bypass and well I had no idea what that is about! Great work sir!
thank you for you video. I have a question for you , most of the time on the job. who is responsible for wiring the timer and the evaporator coil. Electrical contractor or mechanical contractor. thank you sir
Add a rusty, crusty terminal block that can only be accessed while laying on the top of a rickety shelving unit that you just had to remove a soggy mass of melted what was that?
If the defrost clock is just a switch why are you supposed to see voltage at the terminals in the clock shouldn’t you see no voltage if the switch is closed?
@@Colt-wr6wx Yup, a good technician has to be a little of everything to do our jobs right. Now, if I could only learn to use highlight markers properly😆
It may be the most realistic wiring diagram i have seen in my life because this is exactly what you se when you remove a panel. Embrace the spagetti wiring.
😂
This is incredibly valuable and super easy to understand. You’re the man Dave. Awesome video. My favorite to date
This really is great,straight info from a guy who does this everyday.I know really smart people look at this and think so easy,but since I'm not so smart,it seems complex to me.
Dave,your students are lucky because you explain excelent,thanks always the best for you and yours family ,from bronx new york
Thanks Billy
Much appreciated! I am in my last semester of hvac school and we have a walk-in freezer that hasn't run in years. We have a new instructor and much of our training is self taught. This video should help our group get this mistreated freezer back online! lol
How’d it go?
Thank you for this!!
I have mentioned before that my mentor passed away March 2020. This and the walk in cooler wiring were two lessons I still needed to fully understand. (I have done this following direction but did not really "see it".) Now I have your saved videos when I need them.
Again, I know it takes time and energy to do this for those of us with less experience. Big hugs for big thanks!!! 🤗🤗🤗
Your welcome. Sorry for your loss.
Covered this in trade school a lifetime ago, but with no "hands on" experience, remained a bartender for far too long.
Had been in F&B operations for 35 years, barback to management, got bored with pushing paper and for the past five years to chase the blues, as a sideline distraction, have been more or less handling most of the fridge work, (with varying degrees of success and flaming failures) at a horse race track / music venue where I still spend more time pushing paper.
Attended Bryan Orr's first symposium pre-pandemic and met Dick Wirz.
40 years later...watching your back of a cocktail napkin scribbles with free verse keeping it real rambling video has connected more of the dots between my ears than any of all the above.
Be well amigo, would love to ride shotgun with ya one early morn!
Beautifully explained. So useful
With everything in a panic again at work, I needed this. Thanks Dave!
WOW! I understood everything. I'm super new to HVAC-R and in the process of getting my 608.
1 year apprentice here 🤚 Great video 👏 I learned so much from it.
A true professional. Great work
Another nice job Dave, it does get “ busy” in that evaporator at times especially when someone uses all black wire, lol.I found a “missing” defrost timer years ago in the janitors closet at a bakery? The owner thought it was the timer for the parking lot lights 🤣
Well explained! Simple, easy to understand. Spoken like a good journeyman! Thanks!
Good explanation on the wiring. To remember the red brown and black wiring positions, I carry the Dick Wirz refrigeration book in my truck, for the three wire control. Some use two klixons instead of the three wire, Some mount on the tube sheet end of the box while others mount on the 180 bend. The electronics are eliminating much of it now.
I saved this to my UA-cam account I have another one of your defrost videos saved in school they taught us that if you draw it you can wire it from memory gonna have to draw this a few times. Great video thank you for sharing your knowledge and teaching us to be super techs
Yup easy as can be. Once a new tech learns the wiring and sequence of operation everything else gets much simpler. Kind of😎
Bro this was so awesome! I now completely understand basic freezer wiring. Thank you so much. :)
Thank you!
Nice video I need to wire up a evaporator coil tonight and I don't know how to do it but you're giving me a good lesson
Damn man been doing straight AC too long you got me back to trade school w/ ruler & graph paper thx bro
This is the best video to learn defrost timer wiring. 👍
Great video really appreciate it. Simplified a lot of things for this newb. Stay safe keep posting
Excellent video easy to understand 👍
WE LOVE THE LERKERS!! Love that its so catchy lol 😆 Awesome video Dave appreciate the knowledge 👏 👍 👌 😀
I wanna know how you figured out the intro. It's been driving me crazy.
@@joehead1294 all my songs are free at www.reverbnation.com/rasta1
@@NorCal-refrigeration Got tinnitus real bad.
Always thought it said "we love the nor-cers"
Good stuff Dave well explained for the boys !!! 😀
Thank you for the vid Dave!!
Spaghetti is right!! Very intimating until you break it down like you did in this vid.. Great video.. Thanks Dave!!!
Thank you. I love these.
Fantastic!
Thanks for making!
I like the diagram for freezer and the cooler great job 👍🏻👍🏻👍🏻👍🏻👍🏻 I like all videos.
I believe this was the video I was inquiring about🙏🏾
thanks for the extra content Dave
Awesome video
Sweet Jesus! Thank you! So simple.to understand!
My pleasure
Can't wait till next week I start this topic in school I'm gonna be so happy when I understand it ....
Good explanation Super Dave ....Almost made me want to come out of retirement ... I said "almost '' Lol ...
Sir you are the best
THANK YOU SIR
- Houston, TX
Thank you
Awesome video, thank you
great job of explaining that one !!!
Loving this. Thank you
Great video
Thank you so much for this great information. I have a question about reach in freezer box the wiring box before to the main control in the condeser. Some relay and a control of wires
Thank you. It is great, and easy to understand besides that English is a second language for me.
Refrigeration is our 3rd language 🤘⚡️🤘✨✨
Great video!!
You are the man!
OMG BRO IVE NEVER HEARD YOU SING BEFORE 😂😂😂😂💯💯 THAT WAS BAD ASS LOW KEY😂
I definitely got the evap side of it but how does the control voltage get to your contactor up top? Am I bringing #4 from my defrost clock up to one side of the coil voltage on my contactor and the other side goes through my low pressure/high pressure switches?
the time clock controlls your solenoid valve coil. the condensing unit is on its own circuit and the psi switch controls one leg of your contactor. hope that helps.
great explanation.
Thanks for this great information . I learn a lot of this . But i need some information how to wiring the reach in freezers because it has a lot of relays and controls
Thank you for this video.
When you say, that activated "half of the evaporator fans" and then the "fan delay activates the second half". What do you mean by that? All 3 fans run at lower RPM (half speed) first and later on at full speed? Or does it mean that only half of the fans run first and the other half do not at all but only later are turned on when fan delay has reached 35°F? So, do "half fans" refer to lower RPM speed or only half of the fans are running at first stage?
I'm installing a condensing unit with 2 evaporators. Can I wire both evaporators to the defrost timer or do I need to go through contactors ?
Where would you wire in your condensate line heater in this application?
1&N with a 208/230 heater. That how most are here.
@@NorCal-refrigeration what if there’s no wire going from 1 on the roof top timer and the evaporator. Would you go 4&N so the heater is energized for the majority of the run time and just not during defrost?
@@chrisbivens5410 gotcha you could try that if the line freezes up might have to run a circuit to it 115 volt and a 115 volt heater. I’ve seen that a lot also.
Nice setplay bro..
Where can I get 240v to power the A421 when converting from mechanical and the defrost clock (terminal 1) is on the condensing unit? Seems only N is always energized. I've been having to feed in a neutral and run the stat 120v but wish could just use the wiring already available in the freezer evap.
Thansk sir! Its helps me alot🤩
Great, now demonstrate one of these new improved computerized marvels !
Dave this is why your the best hvacr youtuber. Chris is a close second. And is California a big market for geothermal systems?
Working on a turbo air evaporator. Curious.. the freezer was at 65 degrees ( room temp) we couldn't get the fans to kick on to cool the room down. The compressor kept kicking on and off because of low pressure. Does the evap cont. to do that till the fan delay gets to 35 degrees?
The compressor will run low suction until the fans come on.
im trying to process this. I think I got a grip on it. When not in defrost and no call for cooling common sits at the fan delay not actually running fans unless there’s a call from the stat opens the solenoid pressure switch makes temp drops below fan delay set point in which then it makes. Fans run.
Defrost time starts. System pumps down? Heaters run? Until either time is complete or temp on defrost term makes in which we repeat first step.
As long as the box is below 35 the fans always run until defrost. Defrost timer drops one half of fans ( 230 volts ). Usually defrost gets coil above 35 degrees and after defrost the compressor will run with less load on it. Until coil gets to 35 degrees. That’s what the fan delay is in there for.
Thanks Nor-Cal!!!👍👍🔥🔥🔥
So in defrost mode there will be refrigerant in the evaporator coil?
In this the unit pumps down.
👍👍👍 Nice job 🖖🖖👍👍
🤘⚡️🤘
Can I use a 8145-20 time clock to replace a 8141-20. I know the 8141 has 2 nc contacts but the freezer seems it only needs the cooling and defrost only? It’s a norlake old capsule type WI.
Good video Dave. Can you do with a 3 phase condensing unit.
And 95% of electricians are stumped...
They do not understand how condenser and evaporator work in conjunction without electrical circuitry
Dad always said; “wired in series” while Clifford the electrician looked dazed and confused....
Great job Dave!
Good video thanks
Another schematic you nailed it
🇹🇷🤳👍🛠️ nice Job
How is the defrost timer connected to the compressor? Will be another video?
By closing the solenoid and pump down the system
Same as the previous video
Great learning videos! I appreciate it! Would you be doing piping as well? Meaning about hot gas bypass? I was working on a walk in cooler but it had 2 liquid lines and 1 suction. I think the other liquid line was part of the hot gas bypass and well I had no idea what that is about! Great work sir!
You draw better than me.
thank you for you video. I have a question for you , most of the time on the job. who is responsible for wiring the timer and the evaporator coil. Electrical contractor or mechanical contractor. thank you sir
It all depends on bid. But I find most electricians don’t understand how to do it, and bail on it.
@@NorCal-refrigeration thank you sir
Add a rusty, crusty terminal block that can only be accessed while laying on the top of a rickety shelving unit that you just had to remove a soggy mass of melted what was that?
Exactly
😎. Thank you so much.
If the defrost clock is just a switch why are you supposed to see voltage at the terminals in the clock shouldn’t you see no voltage if the switch is closed?
But it can work without thermostat?
Wooooo doggie .... one hell of a diagram there brotha!! 😆🤘🤘🇺🇸🇺🇸
"we're heating up 1 and N" @ 2:54 whoops, made me chuckle :)))
1 and N are not actually h3ating up, they are L1 and L2 . The only load is on the time clock at that point.
That was awesome
yells "klix-on, klix-off, the klixer" LOL, I think I need to quit interneting for the night.
Might as well say clap on clap off.
I love you. thanks
🤘⚡️🤘✨✨
👍🏻👍🏻😎
Favor bro can you make a vedio in condencer. thank you
When will you drop that single an nice work
What do you love the burgers???
excelente
🤘🏻👍🏼
What if it don't go to 1 but "n" and " x"
Yea
I just lost all my hair watching this. U explained it good but still confusing.
The outro song was hitting harder than 480V my guy 😂
There’s a whole playlist HVAC comedy songs on the channel I did. Enjoy.
Now throw in the K2 control🤮, all my supply houses sell them with new boxes, hated them at first, but saves a lot of time
I've been training people with only your video 😂😂😂.. Watch it up until you can sing it
@@agustinalvarez9187 that’s awesome 🤩 thanks
It gets interesting when electrician wires this wrong. It happens a lot
Sure does. Crazy that us mechanics have to know more than they do. Or at least try to. Lol
@@Colt-wr6wx
Yup, a good technician has to be a little of everything to do our jobs right. Now, if I could only learn to use highlight markers properly😆
Is it just me, or does everyone's anxiety increase every time you draw an additional wire on the diagram?
Funky munky explain thats it ….
Great video, but i have a question.
Where does the control voltage go to the contactor? From 4 and n from the defrost timer?