How to Programme the Eastron SDM120 Series (Modbus ID, Baud Rate, Parity, Stop Bits, CT Rate & more)

Поділитися
Вставка
  • Опубліковано 4 лис 2024

КОМЕНТАРІ • 18

  • @sajjakittikaj1090
    @sajjakittikaj1090 Місяць тому

    Can i pair 4 device ? my work is use 4 deivce and change RS485 to Rs232 for connect to MCU

  • @zdenekmasat1491
    @zdenekmasat1491 10 місяців тому +1

    I need advice. I have the product ENERGY METER SDM120M. I would need to change the parameter for "Pulse Output & LED Indicator Mode". Change from "Import & Export" to "Import".
    There is no option in your EEM Meter Settin V2.1.1 software.
    How should I do this, please advise me.

    • @smartprocessltd
      @smartprocessltd  10 місяців тому

      Hello, could you please contact us on email: enquiry@smartprocess.co.uk or by phone: 01268 773 422 and we will discuss what we can do for you.

  • @blissbass4
    @blissbass4 Рік тому +1

    nice video is there a command line to reset to factory thanks

    • @smartprocessltd
      @smartprocessltd  Рік тому

      Hi Blissbass, thank you for your comment. Unfortunately not due to the meter being MID approved. Please let us know if there is anything we can do to help.

  • @stevebest4801
    @stevebest4801 6 місяців тому +1

    Having a right mare, instruction manual clearly states that modbus address, baud, parity and stop bits can be set using the set up menu, does not state anywhere that you require to do it via laptop?! For Mbus it states you have to do it over Mbus communication, but modbus it doesnt?!

    • @smartprocessltd
      @smartprocessltd  6 місяців тому

      Apologies to hear this Steve, If you want to program the ModBus address, Baud Rate etc, you will need to use the relevant communication and connect it up to a laptop or computer to program the meter.

  • @jmadawg
    @jmadawg Рік тому

    If you’ve mistakenly set the CT ratio incorrectly, can this be reset/changed via modbus ?

    • @smartprocessltd
      @smartprocessltd  Рік тому +1

      Yes, you can change it via the modbus / using the software but not from the face of the meter.

    • @Carl-Camera
      @Carl-Camera 11 місяців тому +1

      On the non-MID models you can just change it from the face of the meter.
      www.eastroneurope.com/images/uploads/products/manuals/SDM120_Series_Manual_.pdf

    • @smartprocessltd
      @smartprocessltd  10 місяців тому

      @@Carl-CameraThank you for leaving this comment, to confirm you're able to change the CT rate on the screen of the NON-MID approved models of these meters.

    • @thewildcroft
      @thewildcroft 7 місяців тому

      @@smartprocessltd I've got the CTM version and can't seem to change the CT rate even on the software. Any tips?

  • @LongNguyen-zt9wn
    @LongNguyen-zt9wn 9 місяців тому +1

    i dont have pass word to login sofware . Please support. Thank you!

    • @smartprocessltd
      @smartprocessltd  9 місяців тому +1

      Hello, I think you may have accidently downloaded the EEM Prepay rather than the EEM Meter Setting software as this one does not require a password.

    • @LongNguyen-zt9wn
      @LongNguyen-zt9wn 9 місяців тому +1

      Yes!
      I was downloaded from Eastron website.
      Your software EEM, solis can’t setup in my laptop ( surface book window 10 64 bit).

    • @smartprocessltd
      @smartprocessltd  9 місяців тому +1

      @@LongNguyen-zt9wn I suggest you download the EEM Meter Setting from our website: www.smartprocess.co.uk/pages/downloads

    • @LongNguyen-zt9wn
      @LongNguyen-zt9wn 9 місяців тому +1

      Thank you!
      I was setup it ok.
      But the CT can’t change.
      For example, I’m set it 100A on the metter before, now i want to change it to 200A by software. But can’t.

    • @smartprocessltd
      @smartprocessltd  9 місяців тому

      @@LongNguyen-zt9wn Try press and hold the button on the meter to put it into "set" mode.